Can cooperate with the island prevention experiment;
Provide embedded intelligent PC monitoring system;
1. Output current, voltage limit function;
2. Output frequency 45.000-99.999 Hz, with 0.001 Hz / 10ms variable, can easily and accurately do default frequency experiments, anti-island experiments;
3. LIST. STEP two major modes, can execute 30 sets of different voltage, frequency, time settings, and can be continuously tested. The shortest running time can be set to 10ms, which can be used to simulate grid testing, realize voltage, frequency gradient, step function, and easily 4. Complete low voltage crossing test;
5. The measurement accuracy is high, and it is suitable for testing current sinusoidal half waves and their similar waveforms with DC components;
6. Have an alternative communication interface with RS232C, RS485, and GPIB;
7. Protection mode: overpressure, Overflow, overload, short circuit, current limit, pressure limit, etc.;
8. Provide mean square root voltage, mean square root current, active power, frequency, power factor, peak current, etc..
9. For 100 % deload loading, the reaction time is within 2ms, the overload ability is strong, and the instantaneous current can withstand 3 times the rated current;
10. Voltage, frequency, time digital input, high accuracy, 320 × 240 LCD display;
11. Adopt advanced direct digital frequency synthesizer(DDS) waveform generation technology with high frequency stability and good continuity;
12. Have 9 sets of memories that can store commonly used parameters(voltage V, frequency F) so that they can be easily called when used;
13. Has DC and AC outputs, of which DC voltage can not be adjusted, and is a fixed 300V(single-phase input) and 500V(three-phase input);