2KW-800KW Off-Grid Three Phase Inverter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Inverter
Place of Origin
City, Province
Overview
Power Frequency Pure Sine Wave Inverter Features:l Complete isolation-type inverter technology, noiseless output.l Adoption of advanced SPWM technology, pure sine wave output.l Dynamic current loop co
Product Details

2KW-800KW Off-Grid Three Phase Inverter


2KW-800KW Off-Grid Three Phase Inverter41.png

Power Frequency Pure Sine Wave Inverter Features:

l Complete isolation-type inverter technology, noiseless output.

l Adoption of advanced SPWM technology, pure sine wave output.

l Dynamic current loop control technology to ensure inverter reliable operation.

l Wide DC input voltage range.

l Excellent EMC design.

l Low output harmonic distortion (THD≤3%).

l LED indicators for input voltage range, load power range, normal output & failure state.

l Optional energy saving mode.

l Extensive protections: reverse polarity, short-circuit, overload, under/over input voltage, over-temperature, and inverter’s inner fault identification protections.

l Wide working temperature range (industrial level).

l Continuous operation at full power.

Application

○ For desolate area like mountain, island, pasturing area, etc.

○ For transportation system like beacon light, traffic light, street light, etc.

○ For communication system: unattached operation microwave middle station, optical

cable maintenance station, etc.

○ For solar power station, wind-solar power station, park charging station, family

power house, factory power station, etc.

○ For solar building: has good business future.

○ For the new technology application project.

2KW-800KW Off-Grid Three Phase Inverter1270.png

2KW-800KW Off-Grid Three Phase Inverter1281.png

2KW-800KW Off-Grid Three Phase Inverter1294.png

2KVA off grid three phase inverter technical parameters

Type

SHJ-48-2KSZ

SHJ-96-2KSZ

SHJ-110-2KSZ

SHJ-220-2KSZ

DC input

Input rated voltage

48 VDC

96 VDC

110 VDC

220 VDC

Input rated current

46A

23 A

20A

10 A

Input DC voltage allowing range

40-62 VDC

80-124 VDC

90-140 VDC

180-280 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC± 15% VAC

Input rated current

5A / 3A / 2.9A

Bypass transfer time

≤40 ms (4ms optional)

AC output

Output rated power

2KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

5A / 3A / 2.9A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>90%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

400×660×800 mm

Weight

80 kg

3KVA off grid three phase inverter technical parameters

Type

SHJ-48-3KSZ

SHJ-96-3KSZ

SHJ-110-3KSZ

SHJ-220-3KSZ

DC input

Input rated voltage

48 VDC

96 VDC

110 VDC

220 VDC

Input rated current

69.4A

34.7 A

30.3A

15 A

Input DC voltage allowing range

40-62 VDC

80-124 VDC

90-140 VDC

180-280 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC± 15% VAC

Input rated current

8A / 4.5A / 4.3A

Bypass transfer time

≤40 ms (4ms optional)

AC output

Output rated power

3KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

8A / 4.5A / 4.3A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>90%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

400×660×800 mm

Weight

100 kg

5KVA off grid three phase inverter technical parameters

Type

SHJ-48-5KSZ

SHJ-96-5KSZ

SHJ-110-5KSZ

SHJ-220-5KSZ

DC input

Input rated voltage

48 VDC

96 VDC

110 VDC

220 VDC

Input rated current

115.7 A

57.9A

50.5A

25 A

Input DC voltage allowing range

40-62 VDC

80-124 VDC

90-140 VDC

180-280 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC± 15% VAC

Input rated current

15A / 7.5A / 7A

Bypass transfer time

≤40 ms(4ms optional)

AC output

Output rated power

5KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

15A / 7.5A / 7A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>90%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<3000m

Higher than 3000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

520*920*1050 mm

Weight

135 kg

10KVA off grid three phase inverter technical parameters

Type

SHJ-48-10KSZ

SHJ-96-10KSZ

SHJ-110-10KSZ

SHJ-220-10KSZ

DC input

Input rated voltage

48 VDC

96 VDC

110 VDC

220 VDC

Input rated current

231.5 A

115.7 A

101A

50.5 A

Input DC voltage allowing range

40-62 VDC

80-124 VDC

90-140 VDC

180-280 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC± 15% VAC

Input rated current

28A / 15A / 14.5A

Bypass transfer time

≤40 ms(4ms optional)

AC output

Output rated power

10KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

28A / 15A / 14.5A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>92%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

500*950*1100 mm

Weight

160kg

15KVA off grid three phase inverter technical parameters

Type

SHJ-48-15KSZ

SHJ-96-15KSZ

SHJ-110-15KSZ

SHJ-220-15KSZ

DC input

Input rated voltage

48 VDC

96 VDC

110 VDC

220 VDC

Input rated current

347 A

173.6A

151.5A

75.8A

Input DC voltage allowing range

40-62 VDC

80-124 VDC

90-140 VDC

180-280 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC± 15% VAC

Input rated current

42A / 23A / 21A

Bypass transfer time

≤40 ms(4ms optional)

AC output

Output rated power

15KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

42A / 23A / 21A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave(Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>92%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%,No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

570*1020*1200 mm

Weight

215 kg

20KVA off grid three phase inverter technical parameters

Type

SHJ-48-20KSZ

SHJ-96-20KSZ

SHJ-110-20KSZ

SHJ-220-20KSZ

DC input

Input rated voltage

48 VDC

96 VDC

110 VDC

220 VDC

Input rated current

463A

231A

202 A

101A

Input DC voltage allowing range

40-62 VDC

80-124 VDC

90-140 VDC

180-280 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC± 15% VAC

Input rated current

55.5A / 30A / 29A

Bypass transfer time

≤40 ms(4ms optional)

AC output

Output rated power

20KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

55.5A / 30A / 29A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>92%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

550*1050*1200 mm

Weight

220kg

30KVA off grid three phase inverter technical parameters

cee5a91c73a98658b0933a0f46357ec.jpg


Type

SHJ-110-30KSZ

SHJ-220-30KSZ

SHJ-380-30KSZ

DC input

Input rated voltage

110 VDC

220 VDC

380 VDC

Input rated current

303A

151 A

88 A

Input DC voltage allowing range

90-140 VDC

180-280 VDC

320-500VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC± 15% VAC

Input rated current

83A / 45.5A / 43.5 A

Bypass transfer time

≤40 ms(4ms optional)

AC output

Rated capacity

30KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

83A / 45.5A / 43.5 A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>92%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

520*1160*1375mm

Weight

330 kg

2KW-800KW Off-Grid Three Phase Inverter12138.png

50KVA off grid three phase inverter technical parameters

Type

SHJ-220-50KSZ

SHJ-380-50KSZ

DC input

Input rated voltage

220 VDC

380 VDC

Input rated current

252 A

146.7A

Input DC voltage allowing range

180-280 VDC

320-500VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC ± 15% VAC

Input rated current

139A / 76A / 72.5A

Bypass transfer time

≤100ms(4ms optional)

AC output

Rated capacity

50KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

139A / 76A / 72.5A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>92%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

710*1410*1710 mm

Weight

505 kg

75KVA off grid three phase inverter technical parameters

Type

SHJ-220-75KSZ

SHJ-380-75KSZ

DC input

Input rated voltage

220 VDC

380 VDC

Input rated current

377.8A

218.9 A

Input DC voltage allowing range

180-280 VDC

320-500VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC ± 15% VAC

Input rated current

208A /114A /109A

Bypass transfer time

≤100ms(4ms optional)

AC output

Rated capacity

75KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

208A /114A /109A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>92%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

750*1500*1700 mm

Weight

680kg

100KVA off grid three phase inverter technical parameters

ec8d6d9aab9106ace222cb27f86cf8f.jpg


Type

SHJ-220-100KSZ

SHJ-380-100KSZ

DC input

Input rated voltage

220 VDC

380 VDC

Input rated current

505.6 A

292 A

Input DC voltage allowing range

180-280 VDC

320-500VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC ± 15% VAC

Input rated current

278A / 152A / 145A

Bypass transfer time

≤100ms(4ms optional)

AC output

Rated capacity

100KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

278A / 152A / 145A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>95%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

750*1500*1800 mm

Weight

680 kg

2KW-800KW Off-Grid Three Phase Inverter16616.png

2KW-800KW Off-Grid Three Phase Inverter16620.png

200KVA off grid three phase inverter technical parameters

Type

SHJ-380-200KSZ

SHJ-480-200KSZ

DC input

Input rated voltage

380 VDC

480 VDC

Input rated current

584.4 A

463.3A

Input DC voltage allowing range

320-500 VDC

400-620 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC ± 15% VAC

Input rated current

550A / 300A / 290A

Bypass transfer time

≤100ms(4ms optional)

AC output

Rated capacity

200KVA

Output rated power

160KW

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

550A / 300A / 290A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>95%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

1280*2000*2060mm

Weight

2000 kg

300KVA off grid three phase inverter technical parameters

98273d1c97aff7b91121e4d59783c3d.jpg

Type

SHJ-480-300KSZ

DC input

Input rated voltage

480 VDC

Input rated current

694.4A

Input DC voltage allowing range

400-620 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC ± 15% VAC

Input rated current

830A / 450A / 430A

Bypass transfer time

≤100ms(4ms optional)

AC output

Rated capacity

300KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

830A / 450A / 430A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>96%

Working Environment

Dielectric strength

1500VAC,1分钟minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

1280*2000*2060mm

Weight

2500 kg

500KVA off grid three phase inverter technical parameters

Type

SHJ-480-500KSZ

DC input

Input rated voltage

480 VDC

Input rated current

1157A

Input DC voltage allowing range

400-620 VDC

AC input

(AC bypass)

Allow input voltage range

220 VAC / 380 VAC / 400 VAC ± 15% VAC

Input rated current

1380A / 760A / 725A

Bypass transfer time

≤100ms(4ms optional)

AC output

Rated capacity

500KVA

Output rated voltage and frequency

220 VAC / 380 VAC / 400 VAC,50Hz / 60Hz

Output rated current

1380A / 760A / 725A

Output voltage accuracy

220 VAC / 380 VAC / 400 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>96%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

2150*1400*2300mm

Weight

2600 kg

800KVA off grid three phase inverter technical parameters

Type

SHJ-480-800KSZ

DC input

Input rated voltage

480 VDC

Input rated current

1523 A

Input DC voltage allowing range

400-620VDC

AC input

(AC bypass)

Allow input voltage range

380 VAC ± 15% VAC

Input rated current

969A

Bypass transfer time

≤100ms(4ms optional)

AC output

Rated capacity

800KVA

Output rated voltage and frequency

380 VAC ,50Hz / 60Hz

Output rated current

969A

Output voltage accuracy

380 VAC ± 2%

Output frequency accuracy

50Hz / 60Hz ± 0.05%

Wave

Pure sine wave (Isolation transformer)

THD.

≤3%(Linear load)

Power factor (PF)

0.8

Overload capacity

120%,10 minutes

Over-current capacity

200%,10 seconds

Crest factor (CF)

3:1

Inverter efficiency

>96%

Working Environment

Dielectric strength

1500VAC,1minute

Noise (1m)

≤50dB

Ambient temperature

-10℃~+50℃

Humidity

0~90%, No condensation

Altitude

<2000m

Higher than 2000m rated power should be reduced

Production function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection

Communication interface

RS485/WIFI/GPRS/Ethernet (optional)

Pure Sine Wave

Yes

Equipped With Copper Transformer

Yes

Solar Charger

Optional

AC Charger

Optional

Generator Port

Optional

Size

3600×1000×2200mm

Weight

5500 kg

ec8d6d9aab9106ace222cb27f86cf8f.jpg

9c077dddac3609a83374c77d3111d1b.jpg