FRT AQM integrated environmental monitoring sensor
FRT AQM integrated environmental monitoring sensor is a small instrument that can be used to monitor the environmental monitoring of urban grid, and can monitor Pm2.5, Pm10,H2S,SO2,NO,NO2,O3,CO, noise and other environmental factors, but also integrated monitoring of temperature and humidity, wind speed, air pressure, rainfall, light, ultraviolet and other meteorological elements. System uses the module to carry on the nimble disposition, small in size,low-cost, suitable for grid, intensive. In a word. All-in-one.
Product Features:
Small in size and light in weightMaintenance free, easy to install, no moving partsThe integration of monitoring, grid modelLow power consumption and high precision.
Application:Urban grid particle monitoring
construction site dust monitoring
Smart cityThe wisdom of the community / Industrial Park / factoriesEnvironmental quality assessment
| Item | AQM700 | AQM900 | AQM910 | AQM912 | AQM915 | AQM916 | AQM917 | AQM918 |
| CO | ●
| ●
| ●
| ●
| ●
| ●
| ●
| ●
|
| NO | ●
| ●
| ●
| ●
| ●
| ●
| ●
| ●
|
| NO2 | ● | ● | ● | ● | ● | ● | ● | ● |
| SO2 | ● | ● | ● | ● | ● | ● | ● | ● |
| O3 | ● | ● | ● | ● | ● | ● | ● | ● |
| H2S | ● | ● | ● | ● | ● | ● | ● | ● |
| VOC | ● | ● | ● | ● | ● | ● | ● | ● |
| PM2.5 |
| ● | ● | ● | ● | ● | ● | ● |
| PM10 |
| ● | ● | ● | ● | ● | ● | ● |
| Noise |
|
| ● | ● | ● | ● | ● | ● |
| Temp |
|
|
|
| ● | ● | ● | ● |
| Humidity |
|
|
|
| ● | ● | ● | ● |
| Wind Direction |
|
|
| ● | ● | ● | ● | ● |
| Wind Speed |
|
|
| ● | ● | ● | ● | ● |
| Pressure |
|
|
|
| ● | ● | ● | ● |
| Rainfall |
|
|
|
|
| ● | ● | ● |
| Radiation |
|
|
|
|
|
| ● | ● |
| UVI |
|
|
|
|
|
|
| ● |
Qualification:
| Electrochemical | Measuring range(ppm) | Sensitivity(ppm) | Resolution(ppm) | Overgas(ppm) |
| CO | 0~1000 | 0.001 | 0.03 | 2000 |
| NO | 0~20 | 0.001 | 0.001 | 50 |
| NO2 | 0~20 | 0.001 | 0.001 | 50 |
| SO2 | 0~100 | 0.001 | 0.002 | 200 |
| O3 | 0~20 | 0.001 | 0.5 | 50 |
| H2S | 0~100 | 0.0005 | 0.004 | 200 |
| VOC | 0~100 | 0.2 | 5% | 200 |
| *Option | Measuring range | Resolution | Accuracy | Note |
| Temp | -40~60 | 0.1°C | 0.3°C |
|
| Humidity | 0%~99% | 0.1% | 2% |
|
| Wind D | 0~360° | 1° | 3° |
|
| Wind S | 0~75m/s | 0.1m/s | 0.3m/s or 3% |
|
| Pressure | 10~1300hPa | 0.1hPa | 0.3hPa(25°C) |
|
| Rainfall | 0~5mm/min | 0.2mm | 3% |
|
| Radiation | 0~2000w/m2 | 1w/m2 | 5% |
|
| UVI | 0~15 Class | 1 Class |
|
|
| Noisy | 30~130dB(A) | A Class | 1.5dB |
|
| PM2.5 | 0~1000ug/m3 | 0.3ug/m3 | ±15% or ±10μg/m3 | Laser scattering |
| PM10 | 0~1000ug/m3 | 0.3ug/m3 | ±15% or ±10μg/m3 | Laser scattering |
| TVOC | 0~3Class(9 Class) |
| 5% FS | Ciffusion Type |
| Communication&Power |
|
|
| Communication | RS485/232/Lan / GPRS |
|
|
| Power | DC9~36V |