Product introduction VS1-12 series of Indoor High Voltage Vacuum Circuit Breaker with embedded poles is three phase A.C.50Hz indoor power distribution equipment with the rated voltage of 24kV.It s used for protecting and controlling the electrical equipment in the fileds of...
Product Details
Product introduction
VS1-12 series of Indoor High Voltage Vacuum Circuit Breaker with embedded poles is three phase A.C.50Hz indoor power distribution equipment with the rated voltage of 24kV.It's used for protecting and controlling the electrical equipment in the fileds of industry&mining enterprise,power plants and substation. This type Vacuum Circuit Breaker conforms to national standards and the stipulations of IEC standard.The capability reaches grade of M2-E2-C2. The products is used for many kinds of switchgear like KYN28-12(GZS1)and can be fixed installation.
Applying ambient conditions 1.Ambient temperature:-15ºC~+40ºC. 2.Ambient humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%. 3.Earthquake intensity:not exceed 8 degrees. 4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;the average pressure of a month should be no more than 1.8kPa. 5.The height above sea level:1000m(besides the special requirements). 6.It should be installed in the places without fire,explosion,serious filth,chemical erosion and violent vibration.
Packaging & Delivery.
Packaging Details
Non-solid wooden case(standard export package).
Delivery Detail
Within 10~15 days from the date of receiving signed sales confirmation by both parties.
Parameters
Vs1-12/24KV ZN63A(GTV8) Indoor High Voltage Vacuum Circuit Breaker
Rated voltage
(kV)
12, 24
Rated frequency
(Hz)
50
Rated lightning impulse withstand voltage (peak value)
(kV)
75
Rated short-time power frequency withstand voltage (1min)
(kV)
42
Rated current
(A)
630
630
630
/
1250
1250
1250
/
/
/
1600
1600
/
/
2000
2000
/
/
2500
2500
/
/
3150
3150
Rated short circuit switching current
(kA)
20
25
31.5
40
Rated short time withstand current (RMS)
(kA)
20
25
31.5
40
Rated peak withstand current (peak value)
(kA)
50
63
80
100
Rated short circuit making current (peak value)
(kA)
50
63
80
100
Rated short circuit current duration
(s)
4
Breaking times of rated short circuit current
(times)
50(40kA for 30)
Mechanical life
(times)
20000
Power frequency withstand voltage of secondary circuit (1min)
(V)
2000
Rated operating sequence
0-0.3s-C0-180s-C0
0-180s-C0-180s-C0
Rated single/back-to-back capacitor bank breaking current
(A)
630/400(40kA for 800/400)
Rated capacitor bank making inrush current
(kA)
12.5(frequency ≤1000Hz)
Rated opening and closing operating voltage
(V)
AC110/220, DC110/220
Rated voltage of energy storage motor
(V)
AC110/220, DC110/220
Motor rated power
(W)
70(40kA 100W)
Energy storage time
(s)
≤15
Main conductive loop resistance
630A
≤65μΩ
1250A
≤55μΩ
1600-2000A
≤45μΩ
Above 2500A
≤35μΩ
FAQ:
Q:Why choose us ?
A: we are a factory, we have been manufacturing arrester & fuse cutout & insulator with 13 years .
Q:What is your payment term?
A: T/T 30% down payment, balance to be paid before shipment. or L/C.
Q: Can I get samples from your factory?
A: Yes, Samples can be provided.
Q: If products have some quality problem, how would you deal with?
A: We will responsible for all the quality problems.
Q1: Is OEM/ODM available?
A1: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.