HV Indoor Vacuum Circuit Breaker

Model
Nature of the Manufacturer
Other
Product Category
Vacuum Circuit Breaker
Place of Origin
City, Province
Overview
The vacuum circuit breaker adopts spring energy storage type operating mechanism , which can be operated by electric or manual.It can also be equipped with a permanent magnet actuator with a long service life of 60000 times, which is used in extremely frequent operation places.The vacuum circuit breaker is designed as a re encapsulated structure, which can be used either as a fixed installation unit or as a with draw-able installation unit together with the chassis.The vacuum circuit breaker is manufactured in acco......
Product Details



The vacuum circuit breaker adopts spring energy storage type operating mechanism , which can be operated by electric or manual.It can also be equipped with a permanent magnet actuator with a long service life of 60000 times, which is used in extremely frequent operation places.The vacuum circuit breaker is designed as a re encapsulated structure, which can be used either as a fixed installation unit or as a with draw-able installation unit together with the chassis.The vacuum circuit breaker is manufactured in accordance with the national standard GB1984-2003 and relevant IEC standards.


Application and Attention

1. Guide device must be provided for interrupter during operation. The coaxiality of the moving guide pole and the axis of the arc extinguishing chamber must meet the requirements. Torque on bellows is not allowed.

 

2. During installation, it is forbidden to knock or impact the interrupter shell with hard objects to avoid air leakage due to cracks.

 

3. Pay attention to make sure that the conducting pole is coaxial with the interrupter, and that the conducting pole is perpendicular to the end face of the fixed end.

 

4. Pay attention not to remove the interrupter repeatedly to avoid screw slipping. Do not torque the moving conducting rod, and do not overpressure the bellows, so as to avoid torque force and scratches and reduce the service life of the bellows.

 

5. During installation, the force applied on the surface of both ends shall not exceed the static pressure relief specified in the specification.

 

VS1


Technical Parameter

Item

Description

Unit

Data

1

Rated voltage

KV

12

2

Max. voltage

KV

12

3

Rated current

A

630/1000/1250

1250/1600

/2000/2500

1250/1600

/2000/3150

4

Rated short circuit opening current

KA

20/25

31.5

40

5

Rated short circuit closing current

KA

50/63

80

100

6

Rated peak withstand current

KA

50/63

80

100

7

4s Rated short-time withstand current

KA

20

31.5

40

8

Rated insulation level

Power frequency  

withstand voltage

KV

42,fracture48

Impulse withstand

 voltage(peak)

75,fracture85

9

Rated operating sequence


O-0.3s-C&O-180s-C&O

10

Mechanical life endurance

Times

10000

11

Rated short-circuit opening current sequence

Times

50

12

Clearance between open contacts

mm

11±1

13

Super stroke (the compress length of contact spring)

mm

3.5±0.5

14

Different period among phases for  breaking and closing

ms

≤2

15

Bounce time of contact close break

ms

≤2

16

Average break speed

m/s

0.9~1.2

17

Average closing speed

m/s

0.5~0.8

18

Opening time

Under max.operating

 voltage

s

≤0.05

Under min.operating

 voltage

≤0.08

19

Closing time

s

≤0.1

20

Resistance of each phase main loop

μΩ

630A≤65;1250A≤60

21

Contacts limit erosion

mm

3