Welcome Customer !

Membership

Shanghai wenshun Electric Appliance Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 电力设备

Xwboo>Products

Shanghai wenshun Electric Appliance Co., Ltd.Free·1YRS

  • E-mail

    loadbanks@163.com,ifdx@163.com

  • Phone

    021-50864311

  • Address

    290 Shenmei Road, Shanghai, China

Contact Now

Inverter anti islanding test

Model
Nature of the Manufacturer
Other
Product Category
AC / DC load
Place of Origin
City, Province
Overview
Inverter anti islanding test
Product Details



Product Description:


Photovoltaic grid connected power generation system belongs to distributed power supply system. When the power supply is interrupted due to electrical failure, misoperation or natural factors, each photovoltaic grid connected power generation system is still running,


And the connection with the local load is in an independent operation state, which is called island effect. Considering power safety and power quality, isolated island is not allowed. So, photovoltaic


The grid connected power generation system shall have the ability to detect the island state and stop the grid connected operation quickly and effectively.


In order to meet the anti islanding test and detection requirements of grid connected inverter. Wstf-87300 series anti islanding resonant load can simulate various RLC AC loads and various working environments of inverter


Measuring the actual output power and load capacity of the inverter can detect and debug the resonance point of the photovoltaic inverter. The host has built-in pure resistive load and inductive load, and the power input adopts segmented combined control,


Various power inputs can be combined arbitrarily.


The wstf-87300 series anti islanding resonance load we provide can accurately detect the output power and load capacity of various generator sets.


Function introduction:


1. The main loop consists of resistive network, perceptual network and capacitive network.


2. The combination can realize the adjustable power factor of ± 0.3 ~ 1.


3. RLC three-phase independent split phase control


4. Simulate the resonance of AC electrical equipment and effectively and accurately detect the anti islanding effect protection function of grid connected inverter.


5. Detect the working efficiency, maximum output power and load capacity of various inverters under full load operation.


6. Simulate various complex working environments and detect the comprehensive working performance of the inverter in various environments.


7. It is applied to the product acceptance and daily maintenance detection of grid connected inverters by users, comprehensively and scientifically detect the power supply capacity of various inverters, and accurately provide detection reports.


Application fields:


It is used in the fields of grid connected inverter delivery inspection, type test, production commissioning, scientific research and development, laboratory electrical test, identification and detection of authoritative institutions, etc.



Product name

Wstf-87300 series RLC anti islanding resonant load

model

WS-87310

WS-87330

WS-873100

Main technical indexes of load box

Rated voltage

AC 220V

AC 380V / 220V three-phase four wire system

AC 380V / 220V three-phase four wire system

Rated power

Resistance 10kw

Resistance 30KW

Resistance 100kW

Inductance 10var

Inductance 30kvar

Inductance 100kvar

Capacitance 10var

Capacitance 30kvar

Capacitance 100kvar

load balance

NA

Three phase independent adjustable

Three phase independent adjustable

Maximum current

45A

45A

151A

Rated frequency

50Hz

50Hz

50Hz

Load properties

Resistive inductive capacitive integration

Resistive inductive capacitive integration

阻性感性容性一体化

PF±0.3~1.0

PF±0.3~1.0

PF±0.3~1.0

Quality factor

Q=1.0

Q=1.0

Q=1.0

Minimum step

0.001Kva

0.01kva (per phase)

0.01Kva(每相)

accuracy

≤1%F.S.

≤1%F.S.

≤1%F.S.

control mode

Manual

Programmable

Manual

Programmable

Manual

Programmable

Panel layout

power switch

power switch

power switch

power switch

power switch

power switch

Power regulating switch

10 Inch Touch Screen

Power regulating switch

10 Inch Touch Screen

Power regulating switch

10 Inch Touch Screen

Digital display instrument

Local / remote transfer switch

Digital display instrument

Local / remote transfer switch

Digital display instrument

Local / remote transfer switch

Buzzer

Buzzer

Buzzer

Buzzer

Buzzer

Buzzer

Emergency stop switch

Emergency stop switch

Emergency stop switch

Emergency stop switch

Emergency stop switch

Emergency stop switch


RS485 communication interface


RS485 communication interface


RS485 communication interface

Communication protocol

NA

Modbus RTU communication protocol

NA

Modbus RTU communication protocol

NA

Modbus RTU communication protocol

Data monitoring

Current, voltage, apparent power, active power, reactive power, power factor, frequency

Three phase current, three-phase voltage, apparent total power, three-phase active power, three-phase reactive power, power factor, frequency

oltage resolution

≤1%F.S.

Current resolution

≤1%F.S.

Power Resolution

≤1%F.S.

Protection function

Short circuit protection of working power
Short circuit protection of working power supply
   PLC fault protection (programmable)

Instrument fault protection (programmable)

Heat dissipation mode

Forced air cooling

Working power supply

AC 220V   50Hz

AC 380V   50Hz

Installation mode

Indoor, vertical cabinet type, with universal casters at the bottom

Indoor, vertical cabinet type, with universal casters at the bottom

Indoor, vertical cabinet type, with universal casters at the bottom

Overall dimension

1300-620-700mm h * w * D

1900-900-1050mm h * w * D

2200-1300-1650mm h * w * D

Equipment weight

150kg

450kg

900kg

Appearance color

Ral9003 white

Ral9003 white

Ral9003 white