Ws-8700 series - RLC AC load

Model
Nature of the Manufacturer
Other
Product Category
AC / DC load
Place of Origin
City, Province
Overview
Ws-8700 series - RLC AC load
Product Details

Ws AC load includes single-phase AC load, three-phase AC load, RL resistive load, RLC resistive capacitive load, RCD nonlinear load and other series. Products are widely used in various fields


Daily maintenance test, engineering acceptance, delivery inspection test and product aging of switching power supply, medium frequency aviation power supply and inverter.


It can simulate the test process of starting characteristics, stability characteristics, transient characteristics and output parameters of pure resistive, inductive, capacitive and mixed loads, and detect the stability of AC power supply when connected to different loads


Performance. The optimized subsection type is adopted for power input to meet the needs of different loads and different power factors.


Function introduction:


1. During the project acceptance of newly installed UPS equipment and generator set equipment, check whether the output power of ups and generator set equipment can meet the design requirements.


2. Routine maintenance and inspection of power supply equipment.


3. The user can set and adjust the discharge power, set the discharge time and timing time to automatically turn off the load according to the performance parameters and detection requirements.


4. The load power factor can be set to ± 0.3 ~ 1.0( Resistive load and resistive capacitive load (optional)


5. RS485 communication interface and Modbus RTU standard communication protocol are configured for system integration.


4. After loading, the voltage, current, active power, reactive power, apparent power, power factor, frequency and other parameters of the equipment to be tested can be measured.


5. By controlling the load through computer software, automatic testing can be realized, and the test data can be displayed, recorded and managed( (optional)


6. The test data can be saved in the software database, the historical test data can be queried at any time, exported to excel and other general format files, and printing is supported( Optional).


7. The load has multiple protection functions such as overvoltage, overcurrent, overheating and fan abnormality. It can be unloaded automatically in case of danger. It can also be unloaded forcibly through manual emergency stop switch( (optional)


Application fields:


Test the output power and load capacity of AC charging pile ups, generator set, AC power supply, microgrid, inverter and other AC equipment.


Product selection table:


Product name

Ws-8700 series - RLC AC load

model

WS-8710E

WS-8730E

WS-8750E

WS-87100E

WS-87300E

Main technical indexes of load box

Rated voltage

AC 220V

AC380V/220V    Three phase four wire   

Rated power

resistance10KW

resistance30KW

resistance50KW

resistance100KW

resistance300KW

inductance10Kvar

inductance30Kvar

inductance50Kvar

inductance100Kvar

inductance300Kvar

capacitance10Kvar

capacitance30Kvar

capacitance50Kvar

capacitance100Kvar

capacitance300Kvar

Maximum current

45A

45A

75A

151A

454A

Rated frequency

50Hz

50Hz

50Hz

50Hz

50Hz

Load properties

Resistive inductive capacitive integration

PF±0.3~1.0

Minimum step

0.1Kva

0.1Kva

1Kva

1Kva

1Kva

accuracy

≤1%F.S.

≤1%F.S.

≤1%F.S.

≤1%F.S.

≤1%F.S.

control mode

Manual

Manual

Manual

Manual

Manual

Panel layout

power switch


Power regulating switch


Digital display instrument


Buzzer


Emergency stop switch


power switch


Power regulating switch


Digital display instrument


Buzzer


Emergency stop switch


power switch


Power regulating switch


Digital display instrument


Buzzer


Emergency stop switch


power switch


Power regulating switch


Digital display instrument


Buzzer


Emergency stop switch


power switch


Power regulating switch


Digital display instrument


Buzzer


Emergency stop switch


Data monitoring

Current, voltage, apparent power, active power, reactive power, power factor, frequency

Voltage resolution

≤1%F.S.

Current resolution

≤1%F.S.

Protection function

Short circuit protection of working power supply


Load overvoltage protection


Fan interlock protection


Fan fault protection


Overtemperature protection


PLC fault protection (programmable)


Instrument fault protection (programmable)


Heat dissipation mode

Forced air cooling

Working power supply

AC 220V   50Hz

AC 380V   50Hz

Installation mode

Indoor, vertical cabinet type, with universal casters at the bottom

Overall dimension

1200-620-700
Height * width * depth mm

1700-850-1100高Height * width * depth mm

1900-1100-1200
Height * width * depth mm

1900-1100-1350

Height * width * depth mm

2200-1300-1650

Height * width * depth mm

Equipment weight

150kg

350kg

450kg

650kg

1100kg

Appearance color

Ral9003 white