Ws-erd2000 dual programmable DC feedback load
Product Details


‍

3、 Ws-erd2000 dual programmable DC feedback load


Product overview:


Ws-erd2000 Series Dual programmable DC feedback load adopts high-frequency PWM rectification and bidirectional DCDC conversion technology, FPGA digital control technology, forward and reverse seamless switching, automatic two-way operation, and has the function of energy feedback to the power grid in the full power section. Advanced digital control technology, high control accuracy and fast response speed. The two channels are configured independently and do not affect each other. The channels can be used in parallel to expand the DC output capacity and reduce the customer's equipment investment. Rich programming and testing functions, combined with different host computer software, can be used in a variety of applications.


Product features:


1. Channel independent configuration: each channel is programmed independently, the voltage, current and power parameters are set independently, and the cloth parameters in the programming mode are set independently. The channels are independent and do not affect each other.


2. Parallel use of channels: channels do not affect each other, and two channels can also be used in parallel.


3. Power grid feedback function: it has the characteristics of power supply and load at the same time. In addition to the performance of high-power DC power supply, it realizes the load function of energy automatic feedback to the power grid, and has the outstanding advantages of energy saving, consumption reduction and green environmental protection.


4. High precision output: the precision of output voltage is up to ± 0.05% F.S.


5. Fast dynamic response: 10% - 90% sudden load and 90% - 10% sudden load reduction output voltage response time ≤ 5ms+ 90% ~ - 90% forward and reverse switching time ≤ 10ms.


6. Mainstream high-frequency PWM rectifier control technology, power factor ≥ 0.99, thd and injected harmonic current meet the requirements of national standard GB / T14549-93, and high-quality energy is fed back to the power grid.


7. Advanced IGBT parallel technology is adopted for efficient and reliable operation.


8. There are three working modes: CC, CV and CP.


9. Multiple protection functions: input overvoltage and undervoltage, phase loss, output overvoltage, IGBT overheating, IGBT overcurrent and overtemperature protection, short circuit current limiting protection.


10. Built in EMI filter can well filter out the interference signal caused by high-frequency switching process.


11. Communication and remote control function: standard can, RS232 / RS485 communication interface and host computer remote control software.


12. It has programmable output ramp function.


Application fields:


Test and aging of electric vehicle motor, electric vehicle motor controller, electric vehicle powertrain, electric vehicle DC-DC, and other products.


Technical specifications:

‍

Product name


Ws-erd2000 Series Dual programmable DC feedback load

Product model


WS-ERD2030


WS-ERD2060


WS-ERD2120

Main technical parameters

Rated power

30KW

60KW

120KW

peak power

40KW

75KW

145KW

output voltage

24V - 1000V

24V - 1000V

24V - 1000V

AC characteristics

Rated voltage

380VAC±10%

Rated current

46A

91A

182A

Rated frequency

50Hz±5Hz

Phase line system

Three phase three wire + ground wire (3L + PE)

power factor

≥0.99

harmonic content

≤3%

DC characteristics


Dual channel


Number of channels

2passageway

Setting description

2 channels, output voltage and current can be set independently;


The sum of the two simultaneous powers shall not be greater than the rated maximum power


Voltage range

4v-800v (1000v-1200v voltage optional)

Rated power

30KW

60KW

120KW

Rated current

100A

200A

400A

peak current

120A

240A

480A

Voltage accuracy

0.1%+5dgt(FS)

Current accuracy

0.1%+5dgt(FS)

Voltage resolution

0.1V

Current resolution

0.1A

Power Resolution

0.1KW

response time

≤3mS(10% to 90% sudden load)

Voltage ripple

0.2%FS

Source adjustment rate

0.1%FS

Load adjustment rate

0.1%FS

Feedback characteristics

AC voltage

380VAC±10%

AC frequency

50Hz±5Hz

power factor

≥0.99

Total harmonic content

≤3%

Switching time

≤6mS(+ 90% to - 90% switching)

Feedback power

Support full range power feedback

system

Protection function

Abnormal power supply protection, short circuit protection, overcurrent protection, overload protection, overvoltage protection, undervoltage protection, t overheating protection, output overvoltage protection, communication abnormal protection, etc

Overall efficiency

93%(Pmax)

Communication mode

RS485(standard configuration)

Ethernet (optional)

Can (optional)

Grid isolation

Power frequency transformer

Withstand voltage insulation

Ac2000v 1min no breakdown flicker

Insulation impedance

≥20MΩ

control mode

Local: touch screen / remote: Communication

Degree of protection

IP21 (indoor)

Noise

≤ 65dB (intelligent frequency conversion control)

Cooling mode

Forced air cooling

work environment

temperature

-10℃ - +50℃

humidity

0-95%No condensation

shock

<0.5g

Altitude

<2000rice

Other requirements

No corrosive gas



Product name


Ws-erd2000 Series Dual programmable DC feedback load

Product model


WS-ERD2150


WS-ERD2240


WS-ERD2500

Main technical parameters

Rated power

150KW

240KW

500KW

peak power

180KW

288KW

600KW

output voltage

24V - 1000V

24V - 1000V

24V - 1000V

AC characteristics

Rated voltage

380VAC±10%

Rated current

227A

367A

758A

Rated frequency

50Hz±5Hz

Phase line system

Three phase three wire + ground wire (3L+PE)

power factor

≥0.99

harmonic content

≤3%

DC characteristics


Dual channel


Number of channels

2passageway

Setting description

2 channels, output voltage and current can be set independently;


The sum of the two simultaneous powers shall not be greater than the rated maximum power


Voltage range

24V-800V (1000V-1200VVoltage optional)

Rated power

150KW

240KW

500KW

Rated current

500A

800A

1200A

peak current

650A

960A

1440A

Voltage accuracy

0.1%+5dgt(FS)

Current accuracy

0.1%+5dgt(FS)

Voltage resolution

0.1V

Current resolution

0.1A

Power Resolution

0.1KW

response time

≤3mS(10% to 90% sudden load)

Voltage ripple

0.2%FS

Source adjustment rate

0.1%FS

Load adjustment rate

0.1%FS

Feedback characteristics

AC voltage

380VAC±10%

AC frequency

50Hz±5Hz

power factor

≥0.99

Total harmonic content

≤3%

Switching time

≤6mS(+ 90% to - 90% switching)

Feedback power

Support full range power feedback

system

Protection function

Abnormal power supply protection, short circuit protection, overcurrent protection, overload protection, overvoltage protection, undervoltage protection, t overheating protection, output overvoltage protection, communication abnormal protection, etc

Overall efficiency

93%(Pmax)

Communication mode

RS485 (standard)

Ethernet (optional)

Can (optional)

Grid isolation

Power frequency transformer

Withstand voltage insulation

Ac2000v 1min no breakdown flicker

Insulation impedance

≥20MΩ

control mode

Local: touch screen / remote: Communication

Degree of protection

IP21(indoor)

Noise

≤65db(intelligent frequency conversion control)

Cooling mode

Forced air cooling

work environment

temperature

-10℃ - +50℃

humidity

0-95%No condensation

shock

<0.5g

Altitude

<2000rice

Other requirements

No corrosive gas

Weight (kg)

1400

2100

4200

Volume (mm) w * D * h

1200W*1000D*2000H

1200W*1200D*2000H

2000W*1000D*2000H