Metal Oxide Surge Arrester (MOA) originates from the United States and Japan in 1980s and is promoted as a new generation of surge arresters and integrated with the most advanced technology than the conventional MOAs. After the full introduction of this technology into China in the mid-1980s and absorb of the technology, the performance of AC surge arresters produced by various professional factories is identical to those produced in the US, Japan, Western Europe and other countries. The products that truly met all......
Product Details
YHSeries Metal Oxide Surge Arrester
Part 1 Overview
The surgearrester isthe basis for the insulation coordination ofvarious types of electrical equipment (Transformers, reactors, capacitors, generators, motors, PTs, CTs, circuit breakers, contactors, etc.) in the power system. The protective performance of the surge arrester determines the inside and outside insulation performance (Short durationpower frequency withstand voltage, lightning impulse withstand voltage and switching impactwithstand voltage, etc.)of all electrical equipment in the power system.
Metal Oxide Surge Arrester (MOA)originates from the United States and Japan in 1980s and is promoted as a new generation of surge arresters and integrated with the most advanced technology than the conventional MOAs.After the full introduction of this technologyinto Chinain the mid-1980s andabsorb of the technology, the performance of AC surge arresters produced byvarious professional factories is identical to those produced in the US, Japan, Western Europe and other countries. The products thattruly met all the requirements of Chinese national standard can achieve all the requirements of IEC standard.
The core component of MOA, which is called MOV,is based on the applicationof zinc oxide-based multi-metal oxide powder agglomeration, whichhas excellent nonlinear volt-ampere characteristics, fast response to steep wave and haslarge flow capacity.The gapped MOVadopts a self-blowing gap and has a pressure-equalized irradiation structure, which reduces the dispersion of the discharge and has a small impact coefficient.
The applicationof composite insulated housingconforms to the development trend of miniaturization, safety, and maintenance-free.Compared with inorganic materials such as traditional ceramics and glass, polymer organic composite materials havethe advantages of compactsize,lightweight, resistance to pollution & cleaning free, and explosion-proof and vibration-proof.It is the preferred lightning protection devicein the medium and high voltage integrated and modular power transmission and transformation equipment.
Part 2 Product Designation
According tostandard JB/T 8459-1996 "Surge Arrester Product Model Methodology", the metal oxide surge arrester’s product model methodologyis fined as follows:
(1) When there is no H, it means that the porcelain bushingmetal oxide surge arrester
With H indicates composite bushing metal oxide surge arrester
(2) Nominal discharge current kV
(3) Structural features: W: Gapless; C: Series gap; R: Parallel gap
5. Power frequency voltage applied between the surge arrester terminals for long durationshall not exceed the continuous operating voltage of the surge arrester;
6. Seismic intensity: ≤8 degrees;
7. Maximum wind speed: ≤35m/s.
Part 4 Basic Principal
This series of products are gapless metal oxide surge arresters.Due to the applicationof zinc oxide resistors as its core component, compared with the traditional silicon carbide surge arresters, it has superior volt-ampere characteristics and high flow capacity, which brings about fundamental changes in the surge arrester’scharacteristics.
Under normal operating voltage, the current passing through the surge arrester is only of micro-ampere level and is in an insulating state; when subjected to overvoltage, due to the excellent non-linearity of the zinc oxide resistor, the current flowing through the surge arrester reaches thousands of amperes instantaneously, and the surge arrester is at its on-state, the overvoltage energy is released, and the overvoltage amplitude is limited to the allowable value by the residual voltage of the surge arrester, thereby effectively limiting the damage of the overvoltage to the power transmission and transformation equipment.
Part 5 Model Selection
Users can choose different modelsof surgearrester according to the object to be protected.
In order to meet the needs of the market, wecan design various non-standard products according to the requirements of users.
Part 6 Inspection and Maintenance
First check that the appearance is intact.
Before toput the surge arrestersinto operation, the DC reference voltage U1mAvalue shall be measured. The value shall not be less than the valuespecified in GB 11032-2000 standard. The U1mAleakage currentunder measurementshall not exceed 50μA. It shall bemeasured once every four years after being put into operation to see if it meets the requirements.Gapless surgearresters are not allowed to carry out powerfrequency discharge voltage test.
Part 7 Standard
Product performance is in line with the requirements in GB 11032-2000, IEC 60099-4, IEEEE C62.11 standard.
Part 8 Installation
To Mount in an upright position, the lower electrode studs are attached to the bracket angles.
Please note:
(1) The lower electrode should be connected to the ground wire;
(2) The surge arrester cannot be used as an insulator;
(3) The upper end of the lead wireis preferably a soft copper wire;
(4) Do not disassemble the upper and lower stainless-steelend caps;
(5) Do not use too much force to disassemble and install. Please use a 6 -inch wrench for operation.
Part 9 Common Designations
1. Distribution type: Protection the switchgear, prefabricatedtype substation, power cable outlet, oil switch on pole of the corresponding voltage level and other power distribution equipment from atmospheric and operating over-voltage damage.
Model of Surge Arrester
System Rated Voltage
Rated Voltage of Surge Arrester
Arrester Continuous Operating Voltage of Surge Arrester
DC Reference Voltage
(U1mA)
Residual Voltage under Steep Wave Impulse Current
Residual Voltage under Lightning Impulse Current
Residual Voltage under Switching Impulse Current
Square Wave Flow Capacity
(2ms)
High Current Impact Withstand
(r.m.s) kV
≥ kV
≤ kV
A
kA
HY5WS-5/17
3
5
4.0
8.0
19.6
17
14.5
100
65
HY5WS-5/16
3
5
4.0
8.0
18.8
16
13.5
100
65
HY5WS-10/30
6
10
8.0
16.0
34.5
30
25.5
100
65
HY5WS-10/28
6
10
8.0
16.0
32.5
28
24.5
100
65
HY5WS-17/50
10
17
13.6
25.0
57.5
50
38.5
100
65
HY5WS-17/47
10
17
13.6
25.0
54.5
47
36.5
100
65
HY5WS-51/134
35
51
40.8
76.0
154
134
114
400
65
HY5WS-51/130
35
51
40.8
75.0
150
130
112
400
65
HY5WS-51/125
35
51
40.8
73.0
145
125
110
400
65
HY5WS-52.7/134
35
52.7
42.2
77.0
154
134
114
400
65
HY5WS-52.7/130
35
52.7
42.2
76.0
150
130
113
400
65
HY5WS-52.7/125
35
52.7
42.2
73.0
145
125
110
400
65
HY5WS-54/134
35
54
43.2
77.0
154
124
114
400
65
HY5WS-54/130
35
54
43.2
76.0
150
130
113
400
65
HY5WS-54/125
35
54
43.2
74.0
145
125
110
400
65
HY5WS-84/208
63
84
67.2
122
245
208
178
600
100
HY5WS-84/221
63
84
67.2
125
254
221
188
600
100
HY5WS-90/224
63
90
72.5
130
258
224
188
600
100
HY5WS-94/233
63
94
75.2
133
268
233
195
600
100
HY5WS-96/250
110
96
76.8
145
287
250
213
600
100
HY5WS-100/260
110
100
80.0
151
299
260
221
600
100
HY5WS-102/265
110
102
81.6
154
305
265
226
600
100
HY5WS-108/281
110
108
86.4
163
323
281
239
600
100
HY5WS-116/302
110
116
92.8
175
347
302
256
600
100
HY5WS-192/500
220
192
153.6
290
558
500
424
800
100
HY5WS-200/520
220
200
160.0
302
582
520
442
800
100
HY5WS-204/530
220
204
163.2
308
588
530
452
800
100
HY5WS-216/562
220
216
172.8
326
628
562
478
800
100
HY5WS-228/593
220
228
182.4
344
663
593
504
800
100
1. Power station type: To protect the AC electrical equipment of power plants and substations from atmospheric over-voltage and over-voltage.
Model of Surge Arrester
System Rated Voltage
Rated Voltage of Surge Arrester
Arrester Continuous Operating Voltage of Surge Arrester
DC Reference Voltage
(U1mA)
Residual Voltage under Steep Wave Impulse Current
Residual Voltage under Lightning Impulse Current
Residual Voltage under Switching Impulse Current
Square Wave Flow Capacity
(2ms)
High Current Impact Withstand
(r.m.s) kV
≥ kV
≤ kV
A
kA
HY5WZ-5/13.5
3
5
4.0
7.5
15.5
13.5
11.5
150
65
HY5WZ-10/27
6
10
8.0
15.0
31.0
27
23.0
150
65
HY5WZ-17/45
10
17
13.6
24.0
51.5
45
38.3
150
65
HY5WZ-17/44
10
17
13.6
24.0
50.5
44
37.5
150
65
HY5WZ-51/134
35
51
40.8
76.0
154
134
114
400
65
HY5WZ-51/130
35
51
40.8
75.0
150
130
112
400
65
HY5WZ-51/125
35
51
40.8
73.0
145
125
110
400
65
HY5WZ-52.7/134
35
52.7
42.2
77.0
154
134
114
400
65
HY5WZ-52.7/130
35
52.7
42.2
76.0
150
130
113
400
65
HY5WZ-52.7/125
35
52.7
42.2
73.0
145
125
110
400
65
HY5WZ-54/134
35
54
43.2
77.0
154
134
114
400
65
HY5WZ-54/130
35
54
43.2
76.0
150
130
113
400
65
HY5WZ-54/125
35
54
43.2
74.0
145
125
110
400
65
HY10WZ-51/134
35
51
40.8
75.0
154
134
114
400
100
HY10WZ-51/130
35
51
40.8
73.0
150
130
112
400
100
HY10WZ-51/125
35
51
40.8
74.0
144
125
110
600
100
HY10WZ-51/120
35
51
40.8
72.0
140
120
108
600
100
HY10WZ-52.7/134
35
52.7
42.2
75.0
154
134
114
400
100
HY10WZ-52.7/130
35
52.7
42.2
74.0
150
130
112
400
100
HY10WZ-52.7/125
35
52.7
42.2
72.5
144
125
110
600
100
HY10WZ-54/134
35
54
43.2
76.0
154
134
114
400
100
HY10WZ-54/130
35
54
43.2
75.0
144
130
112
600
100
HY10WZ-94/228
63
94
75.2
133
263
228
200
600
100
HY10WZ-96/250
110
96
76.8
146
280
250
212
600
100
HY10WZ-100/265
110
100
80.0
152
291
260
221
600
100
HY10WZ-102/265
110
102
81.6
155
297
265
225
600
100
HY10WZ-108/281
110
108
86.4
164
314
281
239
600
100
HY10WZ-116/302
110
116
92.8
176
338
302
257
600
100
HY10WZ-126/328
110
126
100.8
192
367
328
279
600
100
HY10WZ-192/500
220
192
153.6
292
560
500
424
800
100
HY10WZ-198/565
220
198
158.4
322
633
565
490
800
100
HY10WZ-200/520
220
200
160.0
304
582
520
442
800
100
HY10WZ-204/530
220
204
163.2
310
594
530
451
800
100
HY10WZ-216/562
220
216
172.8
328
628
562
477
800
100
2. Parallel capacitor type: To suppress over-voltage destruction aroused by switching operation of vacuum switch and less oil switch to the capacitor bank.
Model of Surge Arrester
System Rated Voltage
Rated Voltage of Surge Arrester
Arrester Continuous Operating Voltage of Surge Arrester
DC Reference Voltage
(U1mA)
Residual Voltage under Steep Wave Impulse Current
Residual Voltage under Lightning Impulse Current
Square Wave Flow Capacity
(2ms)
High Current Impact Withstand
(r.m.s) kV
≥ kV
≤ kV
A
kA
HY5WR-5/13.5
3
5
4.0
7.2
10.5
11.5
400
65
HY5WR-10/27
6
10
8.0
14.4
27.0
21.0
400
65
HY5WR-17/44
10
17
13.6
24.0
44
35.0
400
100
HY5WR-17/42
42
34.0
600
HY5WR-17/42
42
34.0
800
HY5WR-17/41
41
34.0*
1000
HY5WR-17/40
40
34.0*
1200
100
HY5WR-48/134
35
48
38.4
72.5
134
105
400
65
HY5WR-48/130
130
HY5WR-48/125
125
HY5WR-48/125
35
48
38.4
72.0
125
102
600
100
HY5WR-48/120
71.0
120
102
HY5WR-48/134
73.0
134
105
HY10WR-48/134
73.0
134
105
HY10WR-48/125
72.0
125
104
HY5WR-48/125
35
48
38.4
73.0
125
104
800
100
HY5WR-48/120
120
HY5WR-48/134
134
HY10WR-48/134
134
HY10WR-48/125
125
HY5WR-48/134
35
48
38.4
74.0
134
105
1000
100
HY5WR-48/125
74.0
125
105
HY5WR-48/120
73.0
120
102
HY10WR-48/134
35
48
38.4
73.0
134
105*
1000
100
HY10WR-48/125
71.0
125
103*
HY10WR-48/120
70.0
120
100*
Note: * is residual voltage under 1kA switching impulse current.
3. Rotary motor type: To Limit the over-voltage generated when the vacuum switch or the less oil switch switches the rotary motor, and protects the rotary motor from over-voltage damage.
Model of Surge Arrester
System Rated Voltage
Rated Voltage of Surge Arrester
Arrester Continuous Operating Voltage of Surge Arrester
DC Reference Voltage
(U1mA)
Residual Voltageunder Steep Wave Impulse Current
Residual Voltageunder Lightning Impulse Current
Residual Voltageunder Switching Impulse Current
Square Wave Flow Capacity
(2ms)
High Current Impact Withstand
(r.m.s) kV
≥ kV
≤ kV
A
kA
HY5WD-4/9.5
3.15
4
3.2
5.7
10.7
9.5
7.6
400
65
HY5WD-8/18.7
6.3
8
6.3
11.3
21.0
18.7
15.0
400
65
HY5WD-13.5/31
10.5
13.5
10.5
18.9
34.7
31.0
25.0
400
65
HY5WD-17.5/40
13.8
17.5
13.8
24.8
44.8
40.0
32.0
400
65
HY5WD-20/45
15.8
20
15.8
28.4
50.4
45.0
36.0
400
65
HY5WD-21/48
20.0
21
16.8
29.0
54.6
48.0
44.0
1200
100
HY5WD-23/51
18.0
23
18.0
32.0
57.2
51.0
40.8
400
65
HY5WD-25/56.2
20.0
25
20.0
35.4
62.9
56.2
45.0
400
65
HY2.5WD-4/9.5*
3.15
4
3.2
5.7
10.7
9.5
7.6
200
65
HY2.5WD-8/19*
6.3
8
6.3
11.3
21.0
19.0
15.0
200
65
HY2.5WD-13.5/31*
10.5
13.5
10.5
18.9
34.7
31.0
25.0
200
65
HY1.5WD-2.4/6**
3.15
2.4
1.9
3.4
6.0
200
65
HY1.5WD-5/12**
6.3
5
4.0
7.1
12.0
200
65
HY1.5WD-8/19**
10.5
8
6.4
11.3
19.0
200
65
Note: * is for application of motor; ** is for application of motor neutral point; rest is for application ofgenerator.
4. Electrified railway type: To protect various electrical equipment, catenaries, and electric locomotives of electrified railways from damage caused by atmospheric over-voltages and operation over-voltages.
Model of Surge Arrester
System Rated Voltage
Rated Voltage of Surge Arrester
Arrester Continuous Operating Voltage of Surge Arrester
DC Reference Voltage
(U1mA)
Residual Voltageunder Steep Wave Impulse Current
Residual Voltageunder Lightning Impulse Current
Residual Voltageunder Switching Impulse Current
Square Wave Flow Capacity
(2ms)
High Current Impact Withstand
(r.m.s) kV
≥ kV
≤ kV
A
kA
HY5WT-42/120
27.5
42
34.0
67
138
120
98
400
65
HY5WT-41/115
27.5
41
32.8
67
133
115
94
400
65
HY5WT-84/240
55.0
84
68.0
134
276
240
196
400
65
HY5WT-82/230
55.0
82
65.6
134
266
230
188
400
65
HY10WT-42/120
27.5
42
34.0
66
138
120
98
400
100
HY10WT-41/115
27.5
41
32.8
66
133
115
94
400
100
HY10WT-84/240
55.0
84
68.0
132
276
240
196
400
100
HY10WT-82/230
55.0
82
65.6
132
266
230
188
400
100
5. Transformer neutral type: To protect the transformer neutral point of the corresponding voltage class from atmospheric over-voltage and operating over-voltage damage.
Model of Surge Arrester
System Rated Voltage
Rated Voltage of Surge Arrester
Arrester Continuous Operating Voltage of Surge Arrester