Metal Oxide Surge Arrester

Model
Nature of the Manufacturer
Manufacturer
Product Category
Lightning Surge Arrester
Place of Origin
City, Province
Overview
Metal Oxide Surge Arrester (MOA) originates from the United States and Japan in 1980s and is promoted as a new generation of surge arresters and integrated with the most advanced technology than the conventional MOAs. After the full introduction of this technology into China in the mid-1980s and absorb of the technology, the performance of AC surge arresters produced by various professional factories is identical to those produced in the US, Japan, Western Europe and other countries. The products that truly met all......
Product Details

YH Series Metal Oxide Surge Arrester

Part 1 Overview

The surge arrester is the basis for the insulation coordination of various types of electrical equipment (Transformers, reactors, capacitors, generators, motors, PTs, CTs, circuit breakers, contactors, etc.) in the power system. The protective performance of the surge arrester determines the inside and outside insulation performance (Short duration power frequency withstand voltage, lightning impulse withstand voltage and switching impact withstand voltage, etc.) of all electrical equipment in the power system.

Metal Oxide Surge Arrester (MOA) originates from the United States and Japan in 1980s and is promoted as a new generation of surge arresters and integrated with the most advanced technology than the conventional MOAs. After the full introduction of this technology into China in the mid-1980s and absorb of the technology, the performance of AC surge arresters produced by various professional factories is identical to those produced in the US, Japan, Western Europe and other countries. The products that truly met all the requirements of Chinese national standard can achieve all the requirements of IEC standard.

The core component of MOA, which is called MOV, is based on the application of zinc oxide-based multi-metal oxide powder agglomeration, which has excellent nonlinear volt-ampere characteristics, fast response to steep wave and has large flow capacity. The gapped MOV adopts a self-blowing gap and has a pressure-equalized irradiation structure, which reduces the dispersion of the discharge and has a small impact coefficient.

The application of composite insulated housing conforms to the development trend of miniaturization, safety, and maintenance-free. Compared with inorganic materials such as traditional ceramics and glass, polymer organic composite materials have the advantages of compact size, light weight, resistance to pollution & cleaning free, and explosion-proof and vibration-proof. It is the preferred lightning protection device in the medium and high voltage integrated and modular power transmission and transformation equipment.

 

Part 2 Product Designation

According to standard JB/T 8459-1996 "Surge Arrester Product Model Methodology", the metal oxide surge arrester’s product model methodology is fined as follows:

fd30e303724cb3714aba38e

(1) When there is no H, it means that the porcelain bushing metal oxide surge arrester

With H indicates composite bushing metal oxide surge arrester

(2) Nominal discharge current kV

(3) Structural features: W: Gapless; C: Series gap; R: Parallel gap

(4) Application: S: For distribution; Z: For substation; R: For capacitor bank; X: For power line; 

D: For generator & motor; F: For protection in hermetical electricals; T: For Railway; O: To be used in oil; 

L: To be used in DC; G: GIS type

(5) Design Serial Number (To be defined by the manufacturer)

(6) Rated Voltage of Surge Arrester kV (r.m.s)

(7) Maximum residual voltage kV (Peak) at nominal discharge current

(8) Additional Features: W: Anti-pollution; G: To be used in plateau; K: Anti-seismic type; J: Surge Counter; 

IM: Monitor; T: For hot & humid condition; L: Disconnector

 

Part 3 Conditions of Application

1. Indoor or outdoor;

2. Ambient temperature: -40 °C ~ +55 °C;

3. The altitude above sea level shall not exceed 3000m (Porcelain bushing surge arrester shall not exceed 1000m);

4. Power frequency: 48Hz ~ 62Hz;

5. Power frequency voltage applied between the surge arrester terminals for long duration shall not exceed the continuous operating voltage of the surge arrester;

6. Seismic intensity: ≤8 degrees;

7. Maximum wind speed: ≤35m/s.

 

Part 4 Basic Principal

This series of products are gapless metal oxide surge arresters. Due to the application of zinc oxide resistors as its core component, compared with the traditional silicon carbide surge arresters, it has superior volt-ampere characteristics and high flow capacity, which brings about fundamental changes in the surge arrester’s characteristics.

Under normal operating voltage, the current passing through the surge arrester is only of micro-ampere level and is in an insulating state; when subjected to overvoltage, due to the excellent non-linearity of the zinc oxide resistor, the current flowing through the surge arrester reaches thousands of amperes instantaneously, and the surge arrester is at its on-state, the overvoltage energy is released, and the overvoltage amplitude is limited to the allowable value by the residual voltage of the surge arrester, thereby effectively limiting the damage of the overvoltage to the power transmission and transformation equipment.

 

Part 5 Model Selection

Users can choose different models of surge arrester according to the object to be protected.

In order to meet the needs of the market, we can design various non-standard products according to the requirements of users.

 

Part 6 Inspection and Maintenance

First check that the appearance is intact.

Before to put the surge arresters into operation, the DC reference voltage U1mA value shall be measured. The value shall not be less than the value specified in GB 11032-2000 standard. The U1mA leakage current under measurement shall not exceed 50μA. It shall be measured once every four years after being put into operation to see if it meets the requirements. Gapless surge arresters are not allowed to carry out power frequency discharge voltage test.

 

Part 7 Standard

Product performance is in line with the requirements in GB 11032-2000, IEC 60099-4, IEEEE C62.11 standard.

 

Part 8 Installation

To Mount in an upright position, the lower electrode studs are attached to the bracket angles.

Please note:

(1)     The lower electrode should be connected to the ground wire;

(2)     The surge arrester cannot be used as an insulator;

(3)     The upper end of the lead wire is preferably a soft copper wire;

(4)     Do not disassemble the upper and lower stainless-steel end caps;

(5)     Do not use too much force to disassemble and install. Please use a 6 -inch wrench for operation.

 

Part 9 Common Designations

1. Distribution type: Protection the switchgear, prefabricated type substation, power cable outlet, oil switch on pole of the corresponding voltage level and other power distribution equipment from atmospheric and operating over-voltage damage.

Model of Surge Arrester

System Rated Voltage

Rated Voltage of Surge Arrester

Arrester Continuous Operating Voltage of Surge Arrester

 

DC Reference Voltage

(U1mA)

Residual Voltage under Steep Wave Impulse Current

Residual Voltage under Lightning Impulse Current

Residual Voltage under Switching Impulse Current

Square Wave Flow Capacity

(2ms)

High Current Impact Withstand

 


(r.m.s) kV

≥ kV

≤ kV

A

kA

HY5WS-5/17

3

5

4.0

8.0

19.6

17

14.5

100

65

HY5WS-5/16

3

5

4.0

8.0

18.8

16

13.5

100

65

HY5WS-10/30

6

10

8.0

16.0

34.5

30

25.5

100

65

HY5WS-10/28

6

10

8.0

16.0

32.5

28

24.5

100

65

HY5WS-17/50

10

17

13.6

25.0

57.5

50

38.5

100

65

HY5WS-17/47

10

17

13.6

25.0

54.5

47

36.5

100

65

HY5WS-51/134

35

51

40.8

76.0

154

134

114

400

65

HY5WS-51/130

35

51

40.8

75.0

150

130

112

400

65

HY5WS-51/125

35

51

40.8

73.0

145

125

110

400

65

HY5WS-52.7/134

35

52.7

42.2

77.0

154

134

114

400

65

HY5WS-52.7/130

35

52.7

42.2

76.0

150

130

113

400

65

HY5WS-52.7/125

35

52.7

42.2

73.0

145

125

110

400

65

HY5WS-54/134

35

54

43.2

77.0

154

124

114

400

65

HY5WS-54/130

35

54

43.2

76.0

150

130

113

400

65

HY5WS-54/125

35

54

43.2

74.0

145

125

110

400

65

HY5WS-84/208

63

84

67.2

122

245

208

178

600

100

HY5WS-84/221

63

84

67.2

125

254

221

188

600

100

HY5WS-90/224

63

90

72.5

130

258

224

188

600

100

HY5WS-94/233

63

94

75.2

133

268

233

195

600

100

HY5WS-96/250

110

96

76.8

145

287

250

213

600

100

HY5WS-100/260

110

100

80.0

151

299

260

221

600

100

HY5WS-102/265

110

102

81.6

154

305

265

226

600

100

HY5WS-108/281

110

108

86.4

163

323

281

239

600

100

HY5WS-116/302

110

116

92.8

175

347

302

256

600

100

HY5WS-192/500

220

192

153.6

290

558

500

424

800

100

HY5WS-200/520

220

200

160.0

302

582

520

442

800

100

HY5WS-204/530

220

204

163.2

308

588

530

452

800

100

HY5WS-216/562

220

216

172.8

326

628

562

478

800

100

HY5WS-228/593

220

228

182.4

344

663

593

504

800

100

1. Power station type: To protect the AC electrical equipment of power plants and substations from atmospheric over-voltage and over-voltage.

Model of Surge Arrester

System Rated Voltage

Rated Voltage of Surge Arrester

Arrester Continuous Operating Voltage of Surge Arrester

 

DC Reference Voltage

(U1mA)

Residual Voltage under Steep Wave Impulse Current

Residual Voltage under Lightning Impulse Current

Residual Voltage under Switching Impulse Current

Square Wave Flow Capacity

(2ms)

High Current Impact Withstand

 

(r.m.s) kV

≥ kV

≤ kV

A

kA

HY5WZ-5/13.5

3

5

4.0

7.5

15.5

13.5

11.5

150

65

HY5WZ-10/27

6

10

8.0

15.0

31.0

27

23.0

150

65

HY5WZ-17/45

10

17

13.6

24.0

51.5

45

38.3

150

65

HY5WZ-17/44

10

17

13.6

24.0

50.5

44

37.5

150

65

HY5WZ-51/134

35

51

40.8

76.0

154

134

114

400

65

HY5WZ-51/130

35

51

40.8

75.0

150

130

112

400

65

HY5WZ-51/125

35

51

40.8

73.0

145

125

110

400

65

HY5WZ-52.7/134

35

52.7

42.2

77.0

154

134

114

400

65

HY5WZ-52.7/130

35

52.7

42.2

76.0

150

130

113

400

65

HY5WZ-52.7/125

35

52.7

42.2

73.0

145

125

110

400

65

HY5WZ-54/134

35

54

43.2

77.0

154

134

114

400

65

HY5WZ-54/130

35

54

43.2

76.0

150

130

113

400

65

HY5WZ-54/125

35

54

43.2

74.0

145

125

110

400

65

HY10WZ-51/134

35

51

40.8

75.0

154

134

114

400

100

HY10WZ-51/130

35

51

40.8

73.0

150

130

112

400

100

HY10WZ-51/125

35

51

40.8

74.0

144

125

110

600

100

HY10WZ-51/120

35

51

40.8

72.0

140

120

108

600

100

HY10WZ-52.7/134

35

52.7

42.2

75.0

154

134

114

400

100

HY10WZ-52.7/130

35

52.7

42.2

74.0

150

130

112

400

100

HY10WZ-52.7/125

35

52.7

42.2

72.5

144

125

110

600

100

HY10WZ-54/134

35

54

43.2

76.0

154

134

114

400

100

HY10WZ-54/130

35

54

43.2

75.0

144

130

112

600

100

HY10WZ-94/228

63

94

75.2

133

263

228

200

600

100

HY10WZ-96/250

110

96

76.8

146

280

250

212

600

100

HY10WZ-100/265

110

100

80.0

152

291

260

221

600

100

HY10WZ-102/265

110

102

81.6

155

297

265

225

600

100

HY10WZ-108/281

110

108

86.4

164

314

281

239

600

100

HY10WZ-116/302

110

116

92.8

176

338

302

257

600

100

HY10WZ-126/328

110

126

100.8

192

367

328

279

600

100

HY10WZ-192/500

220

192

153.6

292

560

500

424

800

100

HY10WZ-198/565

220

198

158.4

322

633

565

490

800

100

HY10WZ-200/520

220

200

160.0

304

582

520

442

800

100

HY10WZ-204/530

220

204

163.2

310

594

530

451

800

100

HY10WZ-216/562

220

216

172.8

328

628

562

477

800

100

 

2. Parallel capacitor type: To suppress over-voltage destruction aroused by switching operation of vacuum switch and less oil switch to the capacitor bank.

Model of Surge Arrester

System Rated Voltage

Rated Voltage of Surge Arrester

Arrester Continuous Operating Voltage of Surge Arrester

 

DC Reference Voltage

(U1mA)

Residual Voltage under Steep Wave Impulse Current

Residual Voltage under Lightning Impulse Current

Square Wave Flow Capacity

(2ms)

High Current Impact Withstand

 

(r.m.s) kV

≥ kV

≤ kV

A

kA

HY5WR-5/13.5

3

5

4.0

7.2

10.5

11.5

400

65

HY5WR-10/27

6

10

8.0

14.4

27.0

21.0

400

65

HY5WR-17/44

10

17

13.6

24.0

44

35.0

400

100

HY5WR-17/42

42

34.0

600


HY5WR-17/42

42

34.0

800


HY5WR-17/41

41

34.0*

1000


HY5WR-17/40

40

34.0*

1200

100

HY5WR-48/134

35

48

38.4

72.5

134

105

400

65

HY5WR-48/130

130

HY5WR-48/125

125

HY5WR-48/125

35

48

38.4

72.0

125

102

600

100

HY5WR-48/120

71.0

120

102

HY5WR-48/134

73.0

134

105

HY10WR-48/134

73.0

134

105

HY10WR-48/125

72.0

125

104

HY5WR-48/125

35

48

38.4

73.0

125

104

800

100

HY5WR-48/120

120

HY5WR-48/134

134

HY10WR-48/134

134

HY10WR-48/125

125

HY5WR-48/134

35

48

38.4

74.0

134

105

1000

100

HY5WR-48/125

74.0

125

105

HY5WR-48/120

73.0

120

102

HY10WR-48/134

35

48

38.4

73.0

134

105*

1000

100

HY10WR-48/125

71.0

125

103*

HY10WR-48/120

70.0

120

100*

Note: * is residual voltage under 1kA switching impulse current.

 

 

3. Rotary motor type: To Limit the over-voltage generated when the vacuum switch or the less oil switch switches the rotary motor, and protects the rotary motor from over-voltage damage.

Model of Surge Arrester

System Rated Voltage

Rated Voltage of Surge Arrester

Arrester Continuous Operating Voltage of Surge Arrester

 

DC Reference Voltage

(U1mA)

Residual Voltage under Steep Wave Impulse Current

Residual Voltage under Lightning Impulse Current

Residual Voltage under Switching Impulse Current

Square Wave Flow Capacity

(2ms)

High Current Impact Withstand

 

(r.m.s) kV

≥ kV

≤ kV

A

kA

HY5WD-4/9.5

3.15

4

3.2

5.7

10.7

9.5

7.6

400

65

HY5WD-8/18.7

6.3

8

6.3

11.3

21.0

18.7

15.0

400

65

HY5WD-13.5/31

10.5

13.5

10.5

18.9

34.7

31.0

25.0

400

65

HY5WD-17.5/40

13.8

17.5

13.8

24.8

44.8

40.0

32.0

400

65

HY5WD-20/45

15.8

20

15.8

28.4

50.4

45.0

36.0

400

65

HY5WD-21/48

20.0

21

16.8

29.0

54.6

48.0

44.0

1200

100

HY5WD-23/51

18.0

23

18.0

32.0

57.2

51.0

40.8

400

65

HY5WD-25/56.2

20.0

25

20.0

35.4

62.9

56.2

45.0

400

65

HY2.5WD-4/9.5*

3.15

4

3.2

5.7

10.7

9.5

7.6

200

65

HY2.5WD-8/19*

6.3

8

6.3

11.3

21.0

19.0

15.0

200

65

HY2.5WD-13.5/31*

10.5

13.5

10.5

18.9

34.7

31.0

25.0

200

65

HY1.5WD-2.4/6**

3.15

2.4

1.9

3.4


6.0


200

65

HY1.5WD-5/12**

6.3

5

4.0

7.1


12.0


200

65

HY1.5WD-8/19**

10.5

8

6.4

11.3


19.0


200

65

Note: * is for application of motor; ** is for application of motor neutral point; rest is for application of generator.

 

 

4. Electrified railway type: To protect various electrical equipment, catenaries, and electric locomotives of electrified railways from damage caused by atmospheric over-voltages and operation over-voltages.

Model of Surge Arrester

System Rated Voltage

Rated Voltage of Surge Arrester

Arrester Continuous Operating Voltage of Surge Arrester

 

DC Reference Voltage

(U1mA)

Residual Voltage under Steep Wave Impulse Current

Residual Voltage under Lightning Impulse Current

Residual Voltage under Switching Impulse Current

Square Wave Flow Capacity

(2ms)

High Current Impact Withstand

 

(r.m.s) kV

≥ kV

≤ kV

A

kA

HY5WT-42/120

27.5

42

34.0

67

138

120

98

400

65

HY5WT-41/115

27.5

41

32.8

67

133

115

94

400

65

HY5WT-84/240

55.0

84

68.0

134

276

240

196

400

65

HY5WT-82/230

55.0

82

65.6

134

266

230

188

400

65

HY10WT-42/120

27.5

42

34.0

66

138

120

98

400

100

HY10WT-41/115

27.5

41

32.8

66

133

115

94

400

100

HY10WT-84/240

55.0

84

68.0

132

276

240

196

400

100

HY10WT-82/230

55.0

82

65.6

132

266

230

188

400

100

 

5. Transformer neutral type: To protect the transformer neutral point of the corresponding voltage class from atmospheric over-voltage and operating over-voltage damage.

Model of Surge Arrester

System Rated Voltage

Rated Voltage of Surge Arrester

Arrester Continuous Operating Voltage of Surge Arrester

 

DC Reference Voltage

(U1mA)

Residual Voltage under Steep Wave Impulse Current

Residual Voltage under Lightning Impulse Current

Square Wave Flow Capacity

(2ms)

High Current Impact Withstand

 

(r.m.s) kV

≥ kV

≤ kV

A

kA

HY1.5W-55/132

110

55

44.0

79

132

126

400

65

HY1.5W-60/144

110

60

48.0

86

144

135

400

65

HY1.5W-72/186

110

72

58.0

103

186

174

400

65

HY1.5W-73/200

110

73

58.4

105

200

165

400

65

HY1.5W-96/260

500

96

76.8

137

260

243

600

100

HY1.5W-102/260

500

102

80.0

158

260

243

600

100

HY1.5W-144/320

220

144

115.8

205

320

299

600

100

HY1.5W-146/320

220

146

116.8

208

320

304

600

100

HY1.5W-207/440

330

207

165.6

292

440

410

600

100

HY1.5W-210/440

330

210

168.0

296

440

399

600

100

HY1.5W-132/320*

500

132

105.6

187

320

272

800

100