Testing conditions
(1)Temperature and Humidity:
Unless particularly specified, tests shall be conducted at the temperature (20±2℃) and the humidity (45%-75%RH).
(2) Storage of test specimen batteries:
Specimen batteries to be tested shall be kept at the ambient temperature (23±5℃) and the relative humidity (45%-75%RH).
Measuring instruments and devices:
(1) Dimension
The accuracy of Verniers are specified in 0.02mm, and micrometers or gauges specified in 0.01mm, or those having equal or better accuracy shall be used.
(2) DC Voltmeters:
The accuracy of voltmeters shall be 0.25% (max.) and the input resistance rating shall be 1MÙ or more.
(3) Load Resistance:
Load resistance shall include all resistance throughout external circuits, and its tolerance shall be 0.5% or less.
Test Methods.
(1) Appearance:
Appearance of batteries shall be inspected by visual means.
(2) Dimensions:
Dimensions shall be measured with instruments specified in Subparagraph 4.2(1), and the measuring end one or both shall be insulated when measuring the overall height of the batteries.
Open-Circuit Voltage:Tested specimen batteries shall be kept for 4 hours or longer at the ambient temperature specified in [Table 1], and then the voltage between both terminals shall be measured at the same ambient temperature with a voltmeter as specified in Subparagraph 4.2(2).
(3) Closed-Circuit Voltage:
Tested specimen batteries shall be kept for 4 hours or longer at the ambient temperature specified in [Table 1], and then the closed –circuit voltage between both terminals shall be measured with a voltmeter as specified in subparagraph 4.2(2) while the load resistance as specified in subparagraph 4.2(3) is connected between both terminals at the same ambient temperature as specified above; requiring that the reading measured value shall be taken for 0.8 seconds after the circuit is closed.
(4) Service Life:
Tested specimen batteries shall be kept for 4 hours or longer at the ambient temperature specified in [Table 2].and then shall be continuously discharged at the same ambient temperature and through the specified load resistance specified in Table 2. The discharge shall be continued until the voltage of the tested specimen falls below the end-point voltage of 2.0V, and the time from beginning to end point shall be taken as the service life.
(5) Service Life after High-Temperature Storage:
Tested specimen batteries, after having been stored at the temperature and through the period specified in [Table 3], shall be kept for 4 hours or longer at the ambient temperature (20 ± 2℃), and then shall be continuously discharged through the load resistance specified in [Table 3 ]at same temperature (20±2℃). The discharge shall be continued until the voltage falls below the end-point voltage of 2.0V, and the time from beginning to end point shall be taken as the service life after high-temperature storage.
Other Tests.
The test items specified in Paragraph 4.3 are of conventionality. Otherwise the test specified below shall be conducted when required.
Leakage Test:
Tested specimen batteries shall be visually examined for electrolyte leakage after the batteries have been stored at the conditions specified in [Table 4].