How to reasonably design buffer circuit parameters when designing GTO inverters
1 Introduction
The parameter value of the buffer circuit directly affects the corruption performance of the GTO and the working performance of the entire GTO inverter. Therefore, how to reasonably design buffer circuit parameters when designing GTO inverters has become an important issue.
In this article, through the analysis of the anode current and anode voltage waveforms during the GTO cut off, it proposes and demonstrates that the GTO anode current waveform has nothing to do with the buffer circuit parameter, and the reverse recovery process of the buffer diode is not related to the buffer circuit parameters. On this basis, a simple and practical buffer circuit parameter optimization design scheme was proposed. The GTO buffer circuit element can be determined according to the specific requirements of the GTO device performance. When the anode voltage and turning power consumption waveforms are simulated during the GTO offseeing process, in order to improve the simulation, the measured anode -off current waveform is adopted. And accordingly derived the corruption power consumption wave shape. Compared with the experimental waveform, the error is extremely small. This article proposes a solution for the buffer circuit parameters with "comprehensive indicators" as the target function.
2 The prerequisite for using anode current waveforms to the anode voltage waveform simulation
The GTO buffer circuit can be equivalent to the circuit shown in Figure 1. If the measured anode current is used to simulate the anode voltage, we need to prove the following two conditions:
(1) GTO anode current waveform has nothing to do with buffer circuit parameters;
(2) The reverse recovery process of the buffer diode has nothing to do with the buffer circuit parameters.
2.1GTO anode current waveform has nothing to do with buffer circuit parameters
The entire process can be divided into three stages: the storage time period, the descending time period and the tail time period.
During the storage time period and the decline period, the storage time TS and the decrease time TF value only depends on the ability of the door pole extraction and the GTO internal structure, and it has nothing to do with the buffer circuit parameter. The anode current waveform of these two sections has nothing to do with the buffer circuit parameters.
In the tail time period, the tail current is basically determined by the anode current waveform and temperature of the decreased period, which has nothing to do with the buffer circuit parameters.
It can be seen that after the changes in the buffer circuit parameters, the anode voltage waveform varies greatly, and the four anode current curves are basically completely overlapped. This experiment can verify the correctness of the above analysis.