Inverter failure science: How to solve the short circuit of IC
Generally speaking, a variable frequency speed regulating device (also called inverter and VFD) can be used for up to 10 years under normal circumstances. However, due to the influence of various external factors, the service life of VFD will be reduced. Various faults of VFD will shorten the service life of VFD. In fact, VFD's IC short -circuit failure is easy to deal with, which will not affect the service life of VFD.
VFD's IC short circuit, intermittent oscillation of the switching power supply, and the display panel lights out. This is a typical failure of the overload or short circuit of the switching power supply. The abnormal load causes the protection action of the switching power current detection circuit, causing the switching power supply to be intermittent oscillation.
VFD's IC short -circuit detection method: VFD disconnects the load circuit one by one to check which load circuit of VFD's short -circuit failure, or after power off, test the output of each power supply to see if the resistance value is reduced or short -circuit. Measurement+5V power supply shows a small resistance of 7.8Ω at both ends, while the normal circuit resistance is about hundreds of ω. The judgment+5V load circuit has a short circuit. After the+5V load circuit is disconnected, the switching power supply has a steady output, indicating that the fault is in the+5V load circuit. +5V power from the line terminal to the CPU motherboard, for CPU chip and peripheral circuit. The circuit range is relatively wide. There are many integrated circuits on+5V power supply on the CPU motherboard, reaching more than 20 yuan. If the VFD short -circuit failure is detected through conventional faults, the+5V power pins of each IC circuit must be picked out, and the resistance value of the power output is checked. When picking up a IC power pins, the resistance value of the power output is 7.8Ω.
Before finding the VFD fault IC, it is impossible to predict how many ICs need to be opened. The "exquisite" welding of CPU components is difficult to approach the circuit board of the phone. The IC circuit is a chip component. It is said that the copper foil of the IC pin is thinner than the human hair, which is not exaggerated at all. If you accidentally remove the copper foil, it is difficult to connect. One by one is stupid. Due to the limited load capacity of the VFD switching power supply, over -current protection will be triggered when accessing the fault circuit, and the switching power supply stops output. Therefore, using a larger capacity+5V power supply, a 5Ω 5W current limit resistance is connected on the CPU motherboard. After a few minutes of power, touch the IC chip on the CPU motherboard by hand. The heating chip has an unusual temperature rise, that is, which IC is broken.