There is no response after the inverter is powered on, how to check and repair
During the maintenance of the inverter, it is often encountered that the inverter responds after the power is restored. Constantly speaking, the inverter will have a corresponding mechanical fault prompt even after the power is restored in the case of a mechanical fault. When the inverter does not respond after the power is restored, how can we check and repair it?
Check and method of inverter response after power recovery
1. First, check whether there is an obstacle in the power recovery of the power supply controller. If it is not confirmed, carry out a professional power supply test. If there is a power supply obstacle, just replace the power supply controller cable!
Second, if the power test is constant, we can perform a static test. Adjust the multimeter to the resistance X10 gear, the red meter rod receives the P terminal of the inverter, and the black meter rod receives R, S, and T in sequence. At this time, there will be a resistance value of about tens of ohms and are basically balanced. When the black meter rod is received at the P terminal, and the red meter rod is received in sequence with R, S, and T, there will be a resistance value that is close to infinity. Then receive the red watch stick to the N terminal, repeat the process just now, if the result is the same, the static test is normal.
3. If the static test of the inverter is normal, we can implement the dynamic test, that is, the on-board test. Start the inverter under no-load (no electrical connection) conditions, and detect the U, V, W three-phase output voltage values. If there is a phase loss, three-phase imbalance, etc., there is a mechanical failure of the components or the drive board. Under the condition of constant output voltage (no phase loss, three-phase balance), test with load. The test is preferably a full impedance test.
After the above operations are completed, it is basically possible to determine the specific reason for the non-response of the inverter after the power is restored. It is suggested that the above key steps should be handled by professional inverter maintenance personnel to avoid damage to the inverter.
The reason and solution of the mechanical failure when the inverter is restored to electricity
The mechanical failure of the inverter without indicating its cause usually occurs on three components: one is the contactor; the second is the control panel of the inverter; the third is the power supply module that supplies power to the control panel.
Mechanical fault inspection 1: At the moment when the inverter is re-energized, there is a sound of the contactor pulling in under constant conditions. If there is no such sound, it may be that the contactor is broken.
Repair method: prepare a contactor again.
Mechanical failure inspection 2: If there is no accident in the resistor, check whether there is an error in the power module. If the LED light of the inverter pressurized power supply is on, it indicates that the high-voltage DC power supply is constant. Check that the low-voltage DC power supply has no DC voltage, which is the phenomenon that the switching power supply does not operate. The failure of the switching power supply is equivalent to the failure of the controller tube to work. To check that the DC voltage is not transmitted, it means that the step-down resistor connected between the high-voltage DC terminal and the primary terminal of the pulse transformer destroys the lead, thus causing the high-voltage DC to not be applied to the primary side of the pulse transformer. on the winding. The switching power supply cannot be organized to operate, the entire inverter has no low-voltage three-phase power supply, and there is no indication of mechanical failure.
Repair method: Change the voltage drop resistor.