What is the difference between air compressor soft start and variable frequency air compressor
Soft starter is actually a motor control device with motor soft start, soft parking, load environmental protection and energy saving and various maintenance functions. It is mainly a three-turn series thyristor and an electronic device control loop connected in series between the switching power supply and the motor under test. According to the conduction angle of the three-turn series thyristor, the input working voltage of the motor under test will be changed according to different regulations to complete various functions.
The inverter is the key to the area where the speed must be changed. Its output not only changes the working voltage but also changes the frequency at the same time; the soft starter is actually an AC voltage stabilizer. When the motor is running, the output only changes the working voltage. No frequency changes.
The frequency converter manufacturer pays attention to that the frequency converter has all the functions of a soft starter, but its price is more expensive than that of a soft starter, and the structure is very complicated.
The soft starter is used in the area where the blood pressure is to be run and terminated, and the motor speed ratio will not change at this time; however, the frequency converter is mainly used in the area of variable speed and constant current source, and the speed ratio is determined by the frequency. Inverter manufacturers feel that the big difference between the two is that the inverter can set the operating frequency at will, but the soft starter only has the function of soft start and soft stop.
Soft starter definition and function
The soft starter is connected in series between the switching power supply and the motor under test. According to the fully intelligent control of its internal thyristor to turn on the conduction angle to complete the communication and AC transformation, the input working voltage of the motor is gradually increased from zero with a preset function relationship. Until the start is completed, the full working voltage of the motor is granted, that is, soft start. During the whole process of soft start, the motor torque of the motor is gradually increased, and the speed ratio is also gradually increased until the thyristor is fully turned on, and the motor is working at the rated current. In terms of equipment characteristics, it can complete smooth operation and reduce the amount of running current. Prevent running overcurrent tripping. When the motor reaches the rated speed, the whole process of operation is completed, and the rated current is given for the normal operation of the motor.
Soft starter (soft starter) is a novel motor control device that integrates motor soft start, soft parking, load environmental protection and energy saving and various maintenance functions. It is called SoftStarter overseas. The soft starter selects the three-turn series thyristor as the AC voltage stabilizer, and connects it between the switching power supply and the motor motor stator. This type of power supply circuit is such as a three-phase fully-controlled bridge rectifier power supply circuit. When the soft starter is used to run the motor, the output voltage of the thyristor is gradually increased, and the motor is slowly accelerated until the thyristor is fully turned on. During the operation of the motor, the mechanical equipment characteristics of the rated current are used to complete smooth operation, reduce the amount of running current, and prevent running. Overcurrent trip. When the motor reaches the rated speed, the whole process of operation is completed, and the soft starter automatically replaces the thyristor that successfully completes daily tasks with a bypass AC contactor, and provides rated current for the normal operation of the motor to reduce the heat loss of the thyristor. Increase the service life of the soft starter, improve its work efficiency, and prevent the power grid from environmental pollution of harmonic currents. At the same time, the soft starter also provides the function of soft parking. The whole process of soft parking and soft starting is reversed, the working voltage is gradually reduced, and the speed is gradually reduced to zero, preventing the torque impact caused by random parking.
key function
Overvoltage protection function: The soft starter introduces a current control loop, so the change of the motor current can be tracked and checked anytime, anywhere. According to the setting of the boosting load current and the inverse time control mode, the overvoltage protection function is completed, so that when the motor is loaded, the thyristor is turned off and the alarm system is sent out.
Phase failure maintenance function: During work, the soft starter checks the change of the three-phase line current anytime and anywhere. Once the current failure occurs, it can make a phase failure maintenance response.
Over-temperature maintenance function: Check the temperature of the thyristor heat pipe radiator according to the internal thermal relay of the soft starter. Once the temperature of the heat pipe radiator exceeds the specified value, the thyristor will be automatically turned off and an alarm system will be sent out.
Accurately measure the main parameters of the control loop: When the motor is working, the detector in the soft starter has been monitoring the operation of the motor, and the detected main parameters are given to the CPU for resolution, and the CPU will detect the main parameters for analysis, storage, and analysis. show. Therefore, the motor soft starter also has the function of accurately measuring the main parameters of the control loop.
Other functions: According to the composition of the electronic circuit, many other interlocking maintenance can be completed in the system software.
Inverter Definition and Function
The SPWM that converts the AC current whose working voltage and frequency are fixed and will not change into the AC current whose working voltage and frequency are variable is called a frequency converter. Reduce the impact load caused by the operation of the motor, control the speed of the motor, lengthen the startup time, and reduce the amount of current, so as to achieve the purpose of soft starting, and at the same time, it can also improve the high efficiency of the power grid and the motor. In fact, the frequency converter is mainly used in the level of environmental protection and energy saving. According to the adjustment, the output voltage, current amount and frequency can be changed. General variable speed motor application inverter.
Inverter principle
The frequency converter is a machine and equipment that converts the DC switching power supply (50Hz or 60Hz) into alternating current of various frequencies to complete the speed regulation operation of the motor. And this is in which the control loop controls the main power circuit, the inverter circuit converts the AC current into DC power, the DC positive intermediate power circuit performs smooth filtering on the output of the inverter circuit, and the rectifier circuit inverts the DC power into AC current. (And the key control loop is completed: the whole process of AC-DC-AC). The new technology of frequency conversion was developed in response to the need to communicate the need for infinitely variable speed of AC motors.