What is the difference between the output voltage waveform of high voltage inverter and the output voltage waveform of low voltage inverter
Date: 2022/11/3Read: 91

What is the difference between the output voltage waveform of high voltage inverter and the output voltage waveform of low voltage inverter

Jun 07, 2022

What is the difference between the output voltage waveform of high voltage inverter and the output voltage waveform of low voltage inverter

High-voltage and high-power variable frequency speed control devices are widely used in various fans, pumps, compressors, rolling mills, etc.

Pump loads, which are widely used in metallurgy, chemical, electric power, municipal water supply and mining industries, account for about 40% of the energy consumption of the entire electrical equipment, and the electricity bill even accounts for 50% of the water production cost in the waterworks. This is because: on the one hand, the equipment is usually designed with a certain margin; on the other hand, due to changes in working conditions, the pump needs to output different flow rates. With the development of the market economy and the improvement of automation and intelligence, the use of high-voltage frequency converters to control the speed of pump loads is not only beneficial for improving the process and product quality, but also a requirement for energy saving and economical operation of equipment. The inevitable trend of sustainable development. The benefits of speed control for pump loads are numerous. From the application examples, most of them have achieved good results (some can save energy as high as 30%-40%), greatly reducing the cost of water production in the water plant, improving the degree of automation, and helping the pump and pipe network. Reduced pressure operation reduces leakage and pipe burst, and can prolong the service life of the equipment.

The high-voltage inverter is composed of multiple power units connected in series. Each power unit outputs a pulse waveform, which is controlled by carrier phase shift, so that the waveform after the series connection of the power units is multi-level, which is very close to a sine wave.

Product definition The adjustable output frequency AC motor drive with a voltage level lower than 690V is classified as a low-voltage inverter.

The output waveform of the low-voltage inverter is a pulse wave similar to that of a single power unit (each power unit is equivalent to a low-voltage single-phase inverter).

Why is the input current of the inverter always less than the output current?

The input voltage of the inverter is rated voltage, and the output voltage of the inverter is generally less than the rated voltage; 2) The power factor of the inverter generally jumps by 0.95, and the power factor of the motor is generally about 0.85. Therefore, the input current of the inverter is always smaller than the output current.