What is the anti-stall function in the inverter
The so-called inverter anti-stall function is to keep the motor speed within a controllable or allowable range.
If the given acceleration time is too short, the change of the output frequency of the inverter far exceeds the change of the rotation speed (electric angle frequency), the inverter will trip due to the overcurrent flowing, and the operation will stop, which is called stall. In order to prevent the motor from stalling and continue to run, it is necessary to detect the magnitude of the current for frequency control. When the acceleration current is too large, the acceleration rate is appropriately slowed down. The same is true when slowing down. The combination of the two is the stall function.
As we all know, generally speaking, the speed of the four-pole motor is 1440 rpm. Likewise, the bipolar motor spins at 2880 rpm.
The adjustable frequency range of the inverter is 0~400hz, of course, there are also inverters with higher frequencies. At 50hz, the speed of the motor reaches the rated frequency of the motor. If the frequency reaches 100hz, the speed must be much higher. If the actual speed of the motor exceeds n times the rated speed, the motor will lose control and may even cause a safety accident.
The inverter's stall prevention function sets the upper limit of the motor speed. Of course, this upper limit is achieved by controlling the frequency, since most frequency converters are open-loop controlled.
The anti-stall function of the inverter includes two aspects:
1. During acceleration:
(1) If the acceleration time is too short, it is easy to jump due to overcurrent.
(2) The acceleration time is too long, which will affect the operating efficiency of the machine. Moreover, the working conditions of production machines also change from time to time, which brings difficulties to the user in the preset "acceleration time", and it is difficult to quickly preset just right. When the drive experiences overcurrent during acceleration, a "trip prevention" procedure (also known as an automatic handler) can be initiated without tripping.
The specific method is: if the current exceeds the preset upper limit (that is, the maximum allowable value of the acceleration current), the output frequency of the converter will not increase, and the acceleration will be delayed until the current falls below the upper limit.
2. Deceleration process: For inertial loads, if the deceleration time is set too short, the DC circuit will be over-voltage due to the function of the drag system. If the DC voltage exceeds the upper limit (that is, the maximum allowable DC voltage) during the deceleration process, the output frequency of the inverter will no longer drop, the deceleration will pause, and the DC voltage will continue to decelerate after it drops below the set value. We often call this function the inverse function.