How to prevent the IGBT from blowing up when the inverter is turned on
As we all know, the IGBT single tube is quite fragile. The IGBT single tube with the same current capacity is much more fragile than the MOSFET with the same current capacity. That is to say, in the H-bridge of the inverter, there is no problem with the MOSFET going up, but the IGBT goes up, it may be It exploded when loaded. Many people are probably aware of this.
Some friends may think that an IRFP460, 20A/500V MOSFET, and SGH40N60UFD 40A/600V IGBT should be enough to prevent explosions, but the actual situation is that suddenly adding and canceling the load after loading, it is very likely that The machine is fried. Through continuous practice, it is found that as long as specific rules are followed, the occurrence of bombing can be completely prevented. It is the measures of peak current protection that can prevent the IGBT from blowing up.
We solve this problem by looking at several parts:
1. Drive circuit;
2. Current acquisition current;
3. Protection mechanism;
1. Drive circuit
The IGBT used this time is IXYS, IXGH48N60B3D1.
This is a very typical application circuit, which can be used for IGBT or MOSFET, but there are some differences.
1. There is a negative pressure generating circuit,
2. Isolation drive,
3. Separate power supply.
First of all, let's take a general look. This circuit has no protection and is 99% fried when used in the inverter, but we can find out the essence of this circuit.
Let's talk about the main points first:
1: Drive resistor R2, this is very important in the drive, and when D1 is closed, the CGE of the IGBT can be quickly discharged. In fact, depending on the need, this D1 can also be omitted, or a resistor can be connected in series in the D1 loop. Gate resistance when 0FF is off.
Second, the current acquisition circuit
Speaking of this step, it is not far from the protection. My experience is that the current acquisition speed should be very fast, so that the circuit behind can be quickly informed in case of overcurrent or short circuit ->, there is a problem here. Make the IGBT turn off quickly and safely.
How should this circuit be implemented? For the inverter circuit, we can directly use resistance sampling, or we can use the VCE tube voltage drop detection method. There have been many discussions in this forum on tube voltage drop detection, but none of them are really usable, actually used, and tested circuits (except for dedicated driver chips), because the parameters of each practical application are very different. , such as IGBT parameters are different, there are many parameters that need to be adjusted, and some experience is required to adjust.
We can start with the simplest way, using a resistor to detect this current, a short circuit is coming, a voltage drop can be generated on the resistor, and a comparator is used to compare this voltage to determine whether there is an overcurrent or short circuit signal.
If the IGBT is 40A, we can take about 2 times the peak current, that is, 80A, and the RS is 0.01R. If the pulse current exceeds 80A, a voltage of 0.01R*80A=0.8V will be generated on the resistor. This voltage passes through R11, After C11 is blanked, go to the + terminal of the comparator, and compare with the reference voltage from the - terminal. The reference resistance is not set correctly. In practice, please calculate it separately. In this example, 5.1K and 1K resistors can be used to divide the voltage into about 0.81V to - At this time, if the voltage on the sampling resistor RS exceeds 0.8V, the comparator will turn over immediately and output SD 5V level to the external circuit. This changed level signal is the short-circuit overcurrent signal that we need to use later.
With this signal, how do we turn off the IGBT? We can see if the situation takes a soft close, or we can take a direct hard close.
Adopting soft shutdown can effectively prevent the voltage of the circuit from rising at the moment of shutdown. The shutdown characteristics are very soft and gentle, which is very suitable for high-voltage and high-power drive circuits.
If a hard shutdown is adopted, it may cause the voltage overshoot on the high-voltage DC. For example, the high-voltage DC400V may become DC600V in an instant. When I read the records in some materials, it was very difficult to understand: it is closed. , Did the high pressure rise by itself? The reality is real.
If it is difficult for everyone to understand, you can do an experiment. If you have a water tower at home, the clearest thing is that the water tower is on a very high floor, and the tap is on the first floor. Turn on the tap, and the water is left behind. Then close the tap at a very fast speed, you You will hear the sound of the water pipe, and even the water pipe will vibrate a little The analogy of the characteristic principle, I would like to thank him here), the principle of IGBT in the bridge circuit is the same. When the IGBT is seriously short-circuited, if the IGBT is turned off immediately, it will only cause an overshoot induced voltage on the bus (as for why the overshoot occurs, you can check the relevant information, many of which have been mentioned), the tube can resist the past, such as You have very good snubber capacitors in parallel on the DC high voltage bus, there are multiple snubber circuits etc...
More importantly, when the tube is turned off, it will fail, and it will be useless if it is turned off. The IGBT will still be short-circuited by the overshoot voltage, and this short-circuit cannot be recovered, and will immediately damage a lot of circuits. Sometimes this phenomenon can be caused without overvoltage. The specific model of the failure principle is unknown to me, but it is conceivable that the failure may be caused by other parasitic capacitances related to the tube and Miller capacitance, or due to overcurrent. , When the short-circuit signal occurs, the IGBT has already occurred the optimus effect, even if it is turned off, it will not be turned off.
There is also a third method, which is called: secondary shutdown. In short, this method is to detect a short circuit and an overcurrent signal. At this time, the PWM pulse is not intended to be turned off softly or directly, but immediately at this moment. The corresponding VGE drive pulse voltage is reduced to about 8V to judge whether it is still in the overcurrent or short circuit area. If it is, continue to use the 8V drive until the set time, such as multiple us, it will be immediately off, if it is, the PWM will return to normal. This method may be rarely seen in general, so we do not do in-depth research.
After understanding these, we can use the specific shutdown methods according to the situation. Generally, in the 2KW level, within DC380V, directly adopting hard shutdown can meet the requirements. It is only necessary to connect a capacitor with good absorption characteristics in parallel with the H bridge. 600V IGBT can be used.
The key point is that the detection should be fast, and the shutdown should be fast after the detection. Only if it is fast, the IGBT will not burn.