How to measure the output frequency of the inverter?
The output frequency of the inverter refers to the actual value when the inverter is running, which is often slightly different from the given frequency signal. It needs to be measured for our reference for feedback adjustments. If the difference is large, it is necessary to detect the given power supply, load motor and other equipment. There are many ways to detect the actual output frequency of the inverter. Commonly used communication methods are analog output and inverter output.
1 Analog mode, we all know that the inverter has analog input and output parts, where the analog input is used for a given frequency, such as 0-10V DC voltage signal and 0-20mA current signal; the analog output is used to detect the working state of the inverter , such as working voltage, running current, etc. The power and frequency values we want to detect can be given in the form of analog quantities. The same output form includes voltage signal and current signal. This output parameter can be selected in the drive settings. Commonly used testing equipment includes:
1 The ammeter and voltmeter can directly measure and calculate the actual operating frequency according to the meter value. Digital display such as tachometer is more convenient to convert analog quantity to digital quantity for display; 3) Use ad module and PLC to collect analog quantity and convert it into digital quantity for feedback control. In fact, their principle is the same, which is to convert the analog quantity to the actual frequency value. For example, a 10V voltage signal corresponds to a maximum value of 50 Hz and can be converted according to the proportional relationship. For example, the output frequency of a 2.5V inverter is 12.5hz.
2 The communication method is more difficult, but the wiring is relatively simple, no conversion is required, and the value acquisition is more convenient. Now the inverter basically supports the communication control mode, we can not only use it to control the operation of the inverter, such as frequency setting, forward and reverse rotation, etc., but also collect the running status in real time. All data transmission and reception is done over several cables, and operations are also sending corresponding commands. The commonly used communication method is modbus, which is provided by the economical general-purpose inverter. PROFIBUS communication, PROFINET communication and EtherCAT communication are also provided on some large and medium-sized high-performance inverters. We can directly use these communication methods to complete the collection of working frequencies. The specific method should be determined according to the communication format supported by the inverter and the host computer.