How to identify a modified pure sine wave inverter?
The inverter corrected sinusoidal output is the sum of two square waves, one offset by 90 degrees relative to the other. The result is an equally spaced three-level waveform with zero voltage. Peak positive voltage, zero volts; peak negative voltage, zero volts. This sequence repeats. The resulting waveform is very similar to the shape of a sine wave.
A sine wave replaces a pure sine wave.
The waveform in a commercial modified pure sine wave inverter resembles a square wave, but pauses during polarity reversal. Switching states for positive, negative and zero voltage development. In general, the ratio of peak voltage to rms voltage cannot be maintained with a sine wave. The DC bus voltage can be adjusted actively, or the "on" and "off" times can be modified to protect and maintain the same RMS value of the DC bus voltage output to compensate for changes in the DC bus voltage.
Using a technique called pulse width modulation (PWM), the ratio of switching times can be adjusted to vary the RMS voltage while maintaining a constant frequency. The generated gate pulses are provided to each switch according to the development mode to obtain the desired output. The harmonic spectrum in the output depends on the pulse width and modulation frequency. When running asynchronous motors, voltage harmonics are usually not important.
However, harmonic distortion in the current waveform can cause additional heat and possibly pulsating torque.
Many electrical devices work fine on modified sine wave inverter devices, especially those with resistive loads, such as traditional incandescent light bulbs. Items with a switching power supply will almost work fine, but if the item has a power transformer, it may overheat.
However, due to the harmonics associated with the corrected sine wave, the load may operate inefficiently and hum during operation. This also affects the efficiency of the system, since the manufacturer's nominal conversion efficiency does not take into account harmonics. Therefore, pure sine wave inverters can provide higher efficiency than modified sine wave inverters.
Most AC motors run on MSW inverters, which reduce efficiency by about 20% due to harmonic content. However, they can be very noisy. A series LC filter tuned to the fundamental frequency may help.
The topology of the modified sinusoidal inverter is as follows: On-board microcontroller with high-frequency fast switching power of ~50 kHz MOSFETs. The MOSFETs are pulled directly from a low voltage DC source such as a battery. This signal is then placed in parallel through a step-up transformer (usually many smaller transformers to reduce the overall size of the inverter)
produce a higher voltage signal. The output of the step-up transformer is then filtered through a capacitor to generate a high-voltage DC power supply. Finally, this DC source pulses from the microcontroller's additional power MOSFETs to generate the final corrected sinusoidal signal.