Mar 26, 2022

What peripherals does the inverter have? What is each used for?

① The power supply side circuit breaker QF is used for switching on and off the power circuit, and automatically cuts off the power supply in the event of an overcurrent or short-circuit accident to prevent the accident from expanding. If grounding protection is required, an earth leakage circuit breaker can also be used.


② Electromagnetic contactor KM1 is used for power on and off. When the inverter protection function works, the power is cut off. For the restoration of power after the power failure of the power grid, it can prevent automatic re-input to protect the safety of equipment and personal safety.


③ The radio noise filter FIL is used to limit the interference of the inverter to the outside world due to high-order harmonics, and can be selected as appropriate.


④ The AC reactor UL1 is used to suppress the harmonic current on the input side of the inverter and improve the power factor. Whether to choose or not depends on the matching of the power transformer and the inverter capacity and the allowable degree of distortion of the grid voltage. In general, it is better to use it.


⑤ The AC reactor UL2 is used to improve the waveform of the output current of the inverter and reduce the noise of the motor.


⑥ Braking resistor R is used to absorb the regenerative electric energy of motor regenerative braking (also known as regenerative braking), which can shorten the free stop time of large inertia loads. In addition, regenerative braking can also be realized when the potential energy load is released.


⑦ Electromagnetic contactors KM2 and KM3 are used for switching operation between the inverter and the power frequency grid. In this way, KM2 is essential, and the interlock between it and KM3 can prevent the output terminal of the inverter from being connected to the power frequency grid. Once the output terminal of the inverter is mistakenly connected to the power frequency grid, the inverter will be damaged. If the switching function between the inverter and the power frequency grid is not required, KM2 can be omitted. Note that some models require that KM2 can only be switched on and off when the motor and inverter are stopped.