How to detect the actual output frequency of the inverter
The output frequency of the inverter refers to the value during actual operation. It is often slightly different from the given frequency signal. It needs to be measured for our reference for feedback adjustment. If the difference is large, the given source and Load motors and other devices. How to detect the actual output frequency of the inverter? There are many common methods to use the analog output signal and communication of the inverter.
How to detect the actual output frequency of the inverter
1. Analog quantity mode, we all know that the inverter has analog input and output parts, where the analog input is used for a given frequency such as a 0-10v DC voltage signal and a 0-20ma current signal; the analog output is The running voltage, running current, power and the frequency value we want to detect can be given in the form of analog quantity to detect the running status of the inverter. The same output forms include voltage signal and current signal. This output parameter can be selected in the inverter settings. Common detection devices include: 1 ammeter and voltmeter directly measure the actual operating frequency according to the value of the table, 2 is the digital display Such as tachometer, etc., it is more convenient to convert analog quantity into digital quantity for display. 3 is the AD module and PLC to collect analog quantity and convert it into digital quantity for feedback control. In fact, their principle is the same, which is to convert the analog quantity to the actual frequency value. For example, a voltage signal of 10v corresponds to the maximum value of 50Hz, and the conversion can be carried out according to the proportional relationship. For example, the output frequency of the inverter corresponding to 2.5v is 12.5Hz.
2. Communication method. This is relatively difficult, but the wiring is relatively simple. Numerical collection is more convenient without conversion. The current inverters basically support communication control. We can not only use it to control the operation of the inverter, such as frequency setting, forward and reverse, but also real-time collection of operating conditions. All data transmission and reception are through several wires. After the cable is completed, the operation is to send the corresponding command. Common communication methods are MODBUS, which is included in economical and general-purpose inverters. Some medium and large-scale, high-performance inverters also have PROFIBUS communication, PROFINET communication, and ETHERCAT communication. We can directly use these communication methods to complete the collection of operating frequencies. The specific method should be determined according to the communication format supported by the inverter and the host computer.