What is the difference between vector control and vf control
Vector control
The vector control variable frequency speed regulation means that the stator currents Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system are converted into the AC current Ia1Ib1 in the two-phase static coordinate system through the three-phase to two-phase transformation, and then press The directional rotation transformation of the rotor field is equivalent to the DC current Im1 and It1 in the synchronous rotating coordinate system (Im1 is equivalent to the excitation current of the DC motor; It1 is equivalent to the armature current proportional to the torque), and then imitates the control of the DC motor The method is to obtain the control value of the DC motor, and realize the control of the asynchronous motor through the corresponding coordinate inverse transformation.
What is the difference between vector control and vf control
Vector control is a field-oriented control method of a motor:
Take the vector control of an asynchronous motor as an example: it first obtains some flux linkage equations through the equivalent circuit of the motor, including stator flux linkage, air gap flux linkage, and rotor flux linkage. The aeration flux linkage connects the stator and the rotor. The rotor current of a general induction motor is not easy to measure, so it is transferred through the breath to turn it into a stator current.
Then, there are some coordinate transformations, first through the 3/2 transformation, it becomes the static dq coordinate, and then the unit vector generated by the previous flux linkage equation is used to obtain the torque current component and the magnetic field current in the rotating coordinate similar to the DC machine. In this way, decoupling control is realized and the response speed of the system is accelerated.
After 2/3 conversion, three-phase alternating current is generated to control the motor, so that good performance is obtained. To sum up the above: vector control is nothing more than four knowledge: equivalent circuit, flux equation, torque equation, coordinate transformation (including stationary and rotating)
V/F control
VF control is an open-loop control. No matter how the load is disturbed, it will not be affected and output a fixed value. Therefore, at certain times, it is more stable and less susceptible to external environmental interference. However, it is precisely because it is essentially an open-loop control, so its control accuracy is relatively low, and it is impossible to achieve deviation-free control like vector control.
What is the difference between vector control and vf control
The difference between vector control and vf control
The essential difference between vector control and VF control is the addition of voltage phase control. From an operational perspective, vector control generally decomposes the current into torque current and excitation current. Here, the ratio of torque current to excitation current is determined by the rotor position angle (that is, the stator voltage phase). The torque produced by the excitation current is.
For specific implementation, please refer to Mr. Chen Lao's book and any other book on vector control. From a macro point of view, the voltage, current, and frequency of vector control and VF control are not much different when the motor is running stably. They are all three-phase symmetrical AC, and basically meet the voltage-frequency ratio relationship, but in transient processes such as sudden increase or sudden increase. In the case of load shedding, vector control will automatically adjust the applied voltage, frequency, and phase along with the change in speed, so that this instantaneous process can restore balance faster. As for the coordinate transformations in vector control, it is a means to facilitate understanding and description, not an essential problem.
From the motor theory point of view, in the dq synchronous rotating coordinate system, three-phase sinusoidal alternating current can be converted into two-phase direct current, which can simplify calculations and facilitate digital processing. In fact, there is no torque current and excitation current in the real system. Yes, these are a kind of mathematical abstraction, which must be reflected in the actual three-phase alternating current after the calculation is completed and the control is completed. Just like the Laplace change in our mathematics, we can turn a differential equation into an algebraic equation to simplify the operation, and it is a reason to reverse the transformation after the operation is completed.
V/F control is a method of controlling the magnetic flux, and this voltage-frequency ratio may be preset in the system to maintain the magnetic flux at a certain level. It is mainly applied to the inverter to save the energy consumption of the motor.
Vector control can fine-tune the motor according to the needs of customers, and can be used as a servo motor. It is not the pursuit of motor efficiency, but the requirement of engineering to keep track of feedback control.
It can be said that vector control is now an advanced method of AC motors. Voltage-frequency control is designed to maintain a constant magnetic flux of the motor so that the motor maintains a high efficiency.
The advantage of VF control is that it is simple to use, without complicated algorithm flow, coordinate transformation and motor model identification process. It is relatively easy for users to use.
The essence of vector control is to equate an AC motor to a DC motor, and independently control the two components of speed and magnetic field. By controlling the rotor flux, and then decomposing the stator current to obtain the two components of torque and magnetic field, through coordinate transformation, orthogonal or decoupling control is realized.
The proposal of vector control method has epoch-making significance. However, in practical applications, because the rotor flux linkage is difficult to accurately observe, the system characteristics are greatly affected by the motor parameters, and the vector rotation transformation used in the equivalent DC motor control process is more complicated, making the actual control effect difficult to achieve the ideal analysis. result.
From a practical point of view, VF control is the current mainstream control method of frequency converters, supplemented by appropriate compensation methods to improve its performance. At present, the main methods to improve VF control performance are: low-frequency torque compensation, dead zone compensation, dynamic flux control, tracking auto-start, etc., which can be applied to more than 80% of the working conditions. In some occasions that require high dynamics, vector control is required, such as servo, printing, etc.
Vector control is to calculate the current speed and position based on the measured current, voltage, magnetic flux and other data, combined with the resistance and inductance inside the motor, and make necessary corrections, so as to get better results when running at different frequencies. Control mode. Due to the large amount of calculation and the need to know the internal parameters of the motor, it is difficult for general users to obtain a considerable part of the required data. This brings difficulties to the application of vector control. In this regard, the frequency converter must be equipped with the function of automatically detecting the motor parameters.
Generally speaking, vector control can get better performance, low-frequency torque is large, and dynamic response is good, but the application is relatively inconvenient. If the parameters are not suitable, it may not run stably, and the range of use is limited. In practice, it is recommended that users can use VF control and try not to use vector control as much as possible. In fact, in most cases, the high-performance VF with increased torque boost, dead zone compensation, and slip compensation can meet most of the requirements and has better stability.
The main problem of vector control at present is that its applicability is not as strong as that of VF. VF can basically be used with any asynchronous motor, but the vector control is beyond the reach of special motors. When I visited Siemens, they controlled the motors to an astonishing level. They used three motors to drive the second, minute and hour hands of a clock respectively! Think about the concept: one revolution in 12 hours, this kind of ultra-low speed control is beyond my imagination. This is the technology gap! This represents the level of motor control in the world, and the basic principle is vector control.