How to use the inverter to ensure power saving?
Theoretically, the frequency converter can be used for all mechanical equipment with motors. When the motor starts, the current will be 5-6 times higher than the rated value, which will not only affect the service life of the motor, but also consume more electric energy. In the design of the system, the selection of the motor will have a certain margin, and the speed of the motor is fixed, but in actual use, it sometimes runs at a lower or higher speed, so it is very necessary to carry out frequency conversion transformation.
As an electronic circuit, the inverter itself consumes power (about 3-5% of the rated power). The power consumption of a 1.5-hp air conditioner is 20-30W, which is equivalent to a permanent light. It is a fact that the inverter works at industrial frequency and has power saving function.
But there are prerequisites: firstly, high power and fan/pump load; secondly, the device itself has power saving function (software support); and finally, it needs long-term continuous operation.
The above are the three conditions that reflect the power-saving effect. If it is said that inverter power frequency operation can save energy without any prerequisite, it is an exaggeration or commercial hype. Knowing why, you will skillfully use it to serve you. It is necessary to pay attention to the use occasions and conditions to apply it correctly, otherwise it will be blind obedience.
Power factor compensation and energy saving
Reactive power not only increases line loss and equipment heating, but the reduction of power factor leads to a reduction in active power of the grid. A large amount of reactive power is consumed in the line, resulting in low equipment efficiency and serious waste.
After using the frequency control device, due to the effect of the filter capacitor inside the frequency converter, the reactive power loss is reduced and the active power of the grid is increased.
Energy-saving soft start
The hard start of the motor has a serious impact on the power grid, and the requirement on the power grid capacity is too high. The large current and vibration generated during start-up will cause great damage to the baffle and valve, which is extremely detrimental to the service life of equipment and pipelines.
After using the frequency conversion energy-saving device, using the frequency converter's soft start function will make the starting current start from zero, and the maximum value will not exceed the rated current, which can reduce the impact on the power grid and the requirements on the power supply capacity, and extend the service life of the equipment and valves. Save equipment maintenance costs.