How to select and match the inverter according to the motor load characteristics?
When the variable frequency motor is selected to match the inverter, the following two verification tests should be carried out on the basis of detailed analysis of the load characteristics of the motor under actual working conditions: 1) The electromagnetic compatibility of the inverter itself; 2) No load, load, adjustment Performance characteristics such as vibration and noise during speed.
1 Constant torque load
When performing variable frequency speed regulation under constant torque load, the resistance torque on the motor output shaft will not change during the process of increasing or decreasing the motor speed, but the maximum value of the increase speed must not exceed the rated speed, otherwise the motor will be burned due to overload operation . During the speed increase process, there is not only the resistance torque, but also the inertia torque to prevent the speed change, so that the torque on the motor shaft exceeds the rated torque of the motor, and it is possible to break the shaft or trigger various electrical faults due to the overheating of the winding. The so-called constant torque speed regulation actually refers to the constant torque on the output shaft of the motor when the speed is adjusted to any speed for stable operation, and it has the ability to drive a constant torque load. During the acceleration or deceleration of the motor, in order to shorten the transition time, the motor shaft should be able to generate sufficient acceleration or braking torque within the allowable range of the mechanical strength of the motor and the temperature rise of the motor, so that the motor quickly enters a constant rotation. Moment running state.
2 Constant power load
The constant power torque-speed characteristic refers to the constant power provided by the motor when the operating speed of the equipment or machinery changes. For example, rolling mills, lathes, winding machines and conveying equipment have low speeds, large torques and small rotations. The characteristics of high torque and high speed are required, that is, the motor should have the ability to drive variable torque and constant power loads.
When the voltage of the motor increases with the increase of frequency, if the voltage of the motor has reached the rated voltage of the motor, it is not allowed to continue to increase the voltage with the increase of frequency, otherwise the motor insulation will be broken down due to overvoltage . For this reason, after the motor reaches the rated voltage, the motor voltage remains unchanged even if the frequency increases. The output power of the motor is determined by the product of the motor's rated voltage and rated current, and the current no longer changes with the change of frequency, that is It has reached the operating state of constant voltage, constant current and constant power.
In addition to constant power and constant torque loads, the power consumed by some equipment changes drastically with the operating speed. For equipment such as fans and water pumps, the resistance torque is proportional to the 2nd to 3rd power of the running speed, that is, the square torque reduction load characteristic, only need to select the energy-saving frequency converter according to the rated point; The performance requirements of the motor from standstill to normal operating speed during the entire starting process should be considered.