In the bearing mode, the inverter has protection failure, how to correct it?
A company’s EVA device designs 13 silos and installs 14 degassing fans, one degassing fan corresponds to one silo, and the other degassing fan is a backup fan. When a certain silo degassing fan stops due to failure, the standby degassing fan is automatically started, and the short-term stop of the fan has no effect on production.
The equipment uses Germany Aizhen GM801 fan; the motor uses Siemens 1LE0002-3AA2 3-3AB4—Z 315M, rated power 132kW, rated current 235A, rated speed 2980r/min; fan and motor adopt belt transmission power; control method adopts frequency conversion For starting the device, a certain type of frequency converter is selected; the motor is installed on a cantilevered elastic foundation.
At present, there have been accidents of multiple motor bearing shafts during the operation of the equipment. The motor cannot be cranked during the on-site inspection, the bearing temperature is high, and the motor rotor shaft is ground fine, which requires external repair.
1 Failure phenomenon
1.1 Damage to the motor bearing
Since the operation of the equipment in 2013, several motors of the EVA air conveying system have had shaft-clamping phenomenon in the drive-end bearings. As shown in Figure 1, the motor bearing is faulty, and the bearing temperature is measured at about 200℃ on site.
Disassembly and inspection revealed that the inner ring of the motor drive end bearing was running sleeves, the motor rotor shaft was ground fine, and the inner and outer oil caps were worn to varying degrees. It needs to be contracted to repair the shaft size, which leads to an increase in repair costs.
1.2 Protection action
SIS displays "low flow" or "low pressure" process interlock trip; the frequency converter has no fault trip record, and it shows normal stop.
2 Reason analysis
2.1 Analysis of the reasons for the motor bearing to hold the shaft
According to ISO 10816 "International Standard for Vibration Judgment of Rotating Machinery", the vibration of 132kW motor should not be greater than 4.5mm/s, the vibration alarm value of Aizhen fan is 11mm/s, and the vibration trip value is 18mm/s. In actual operation, the motor often runs beyond the allowable vibration standard value, which leads to accelerated motor bearing damage.
The motor has oil filling holes and no oil drain holes, and waste oil cannot be discharged online. After filling for a certain period of time, there is too much waste grease in the bearing room, and the space in the bearing room is limited. In addition, the motor rotates at a speed of 2985r/min, which causes the motor bearing to run. The temperature rises.
Roots blower is noisy, and the abnormal running sound of the bearing is masked by the noise of the roots blower. Sometimes the inspectors cannot find the abnormal running state of the motor bearing in time. Combining the above three factors is the main reason that causes the bearing to hold the shaft of the motor.
2.2 Reason analysis of inverter trip without fault
There is a process from the normal operation of the motor bearing to the locking of the bearing, which takes several minutes or ten minutes. If the frequency converter can promptly protect the trip and stop according to the increase in operating current caused by the motor bearing fault, it will not extend the motor bearing fault to the phenomenon of motor bearing shaft holding, or to the more serious accident of motor rotor shaft wear. Check the parameter settings of the inverter's thermal protection and locked-rotor protection, see Table 1.
Table 1 Inverter thermal protection and locked-rotor protection parameter settings
By checking the protection parameters of the inverter, it is found that the thermal overload protection of the motor does not work. Therefore, although the running current increases to reach the thermal overload action value after the motor bearing is damaged, the inverter does not put in thermal overload protection, so the inverter will not act due to thermal overload protection. And tripped.
The blocking protection time of the inverter is 20s, and the blocking protection setting is 20Hz. The output frequency of the inverter drops to 20Hz after the equipment is blocked, and the inverter will fail and trip when the blocking time reaches 20s. The process interlocking of "low flow rate" and "low pressure rate" reaches the protection action value, and the vehicle jumps in 0.5s. Due to the motor bearing failure, the fan speed is reduced and the air volume is reduced, so the process interlocking trip has priority over the inverter blocking protection trip, and the inverter blocking protection does not work.
3 Corrective measures
3.1 Corrective measures to prevent the motor bearing from holding the shaft
Strengthen the maintenance of the Roots blower, correct the vibration of the motor in time if the motor vibration exceeds the standard, control the vibration value of the motor within the normal range, and strictly prohibit the motor running beyond the standard value of vibration. Refer to "Motor Manufacturing Technology" The depth tolerance code of the bearing room of the domestic motor is h11 and the depth tolerance code of the Siemens motor bearing room is the same as h11. The fixed size of the outer bearing cover of the domestic motor Y2—315—4 is the same as that of the Siemens motor 1LE0002-3AA2 3—3AB4—Z The fixed size of the outer bearing cover of 315M is the same. The outer bearing cover of the domestic motor Y2—315-4 has oil drain holes, which can realize the online oil drain function of the motor, as shown in Figure 3.
Figure 3 Y2—315—4 Bearing cap with oil drain hole
Replace the Siemens motor outer bearing cover with the domestic motor outer bearing cover to realize the online oil drain and change function of the motor, and avoid excessive waste grease in the motor bearing chamber, too high temperature of the motor bearing, and bearing shaft hung accident.
3.2 Rectification measures for the setting of inverter protection parameters
After many on-site observations, when the EVA silo degassing fan inverter starts, the inverter current does not exceed 120A; the maximum normal operating current is within the range of 120~140A, the maximum operating current does not exceed 150A, the rated current of the motor is 235A, and the actual operating current of the motor 85A less than the rated current of the motor is called half-load load. If the thermal overload protection of the inverter is set according to the rated current of the motor, even if the thermal overload protection of the inverter is used, when the motor bearing fails, the inverter cannot generate thermal overload trip protection.
Considering the actual operating conditions of the motor, a certain safety factor is reserved for the thermal overload protection of the inverter. See Table 1 for the modification of the thermal overload protection of the inverter. 30.04MOTOR THERM PROT motor temperature protection selection FAULT fault trip; 30.05MOT THERM P MODE motor thermal protection mode selection USER MOODE user mode; 30.06MOTOR THERM TIME thermal time constant is set to 256s; 30.07MOTOR LOAD CURVE allows the motor overload continuous current to be considered based on 170A, set to 72.3%; 30.08ZERO SPEED LOAD allows the motor continuous current at zero speed to be set to 51%; 30.09BREAK POINT The drive output frequency under 99% load is set to 50Hz.
For inverter blocking protection, 30.11STALL FREQ HI is changed from the original blocking frequency of 20Hz to 47Hz; 30.12STALL TIME blocking time is changed from the original 20s to 10s.
Refer to the ACS800 inverter manual, 32 SUPERVISION is the monitoring limit value, with the motor current monitoring alarm output function.
Set 32.05CURRENT FUNCTION motor current monitoring function and select the type of limit value monitoring to HIGH LIMIT upper limit; 32.06CURRENT LIMIT motor current monitoring limit value is set to 170A; 14.01 RELAY RO1 OUTPUT selection relay output RO1 display drive status is set to Reach the motor current monitoring limit value; 14.04 RO1 TON DELAY delayed pull-in time is set to 3s; 14.05 RO1 TOFF DELAY delayed release time is set to 1s, see Table 2.
Table 2 Motor current monitoring function setting
The limit current monitoring relay RO1 normally open contact controls the intermediate relay KA6 and KA6 normally closed contacts in series into the inverter starting circuit. When the motor running current reaches 170A, the relay RO1 delays 3 seconds to start the intermediate relays KA6 and KA6 normally closed contacts Disconnect the starting circuit of the inverter, the inverter will stop output, and the motor will stop. At the same time, the KA6 normally open contact is self-maintaining, and the KA6 intermediate relay has its own power indicator, which is convenient for electrical operators to find out the cause of the inverter trip, as shown in Figure 4.
4 Conclusion
1) On-line oil drain function designed for larger power motors
For domestic Wolong Electric Nanyang Explosion-proof Group Co., Ltd., Harbin Electric Group Jiamusi Electric Co., Ltd., and foreign ABB companies, motors with power of 11kW and above can be designed and installed on-line oil filling and drain holes, as shown in Figure 5.
It is recommended that when Party A purchases a motor with a power of 11kW and above, the motor shall have the functions of online oil filling and oil drain holes. By replacing the lubricating grease online by the motor, the service life of the motor bearing can be prolonged, the labor intensity of the electrical maintenance personnel can be reduced, the maintenance period of the motor can be prolonged, the equipment maintenance cost can be reduced, and the operating cost of the enterprise can be reduced.
2) Set the thermal protection current according to the actual maximum operating current
There are a few motors at the production site that have half-loaded loads. The normal operating current of a motor with a half-load load is much lower than the rated current of the motor. When the motor bearing or the bearing of the dragging equipment fails, the motor running current increases. If the inverter thermal overload protection is set according to the rated current of the motor, the inverter thermal overload protection will generally not trip. The motor will continue to run for a long time in the case of a bearing failure, which will cause further expansion of the equipment and mechanical failures.
In order to realize the reliable protection of the inverter of a half-loaded motor against equipment bearing faults, it is recommended that the inverter thermal overload protection should be set according to the reliability factor of 1.05~1.2 times the maximum current of the motor during normal operation to improve the inverter thermal overload protection. Reliability.
3) The frequency converter adds a definite time limit overcurrent protection function
If the motor drive equipment has a small impact on production after the jump, in order to make the frequency converter reliably protect the motor or the bearing failure of the motor drive equipment, according to the actual situation on the site, the ACS800 frequency converter passes 32 sets of limit monitoring values and increases the definite time limit Overcurrent protection function. For inverters with half-load loads, it is recommended to set the overcurrent protection value by a reliability factor of 1.1 to 1.3 times the maximum current value of the motor in daily operation, and increase the 3 to 5s delay trip function to improve the inverter’s bearing on the equipment. The scope of protection of the fault.
In actual operation, the bearing failure of the motor causes the motor shaft to bend, the rotor is swept or the shaft is broken. Most of them are thermal overload protection and timing overcurrent protection of the motor with half load. The starting threshold is set according to the rated current of the motor, ignoring the half load. The maximum current of the motor in daily operation is smaller than the rated current of the motor.
When the bearing of a half-loaded motor fails, although the operating current of the motor increases compared to the maximum current of the motor in normal operation, the starting threshold of the thermal overload protection and timing overcurrent protection of the protection device is not reached or not reached in time, and the motor protection device fails to protect the trip in time , The motor runs for a long time in the case of a bearing failure, which is further expanded into the motor shaft bending and the motor rotor sweeping accident. The equipment after the transformation works well.