Welcome Customer !

Membership

Luoyang Asian Sun Wire & Cable Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 电线电缆

Xwboo>Products

6 AWG Wire Cable

Model
Nature of the Manufacturer
Other
Product Category
LV ABC Cable
Place of Origin
City, Province
Overview
Overhead cable is extensively used in overhead power transmission line and used in city streets and green area, overhead lines closing to the building , the urban construction site and transformer wiring occasion etc..It improves the safety and reliance of electrified wire netting.
Product Details

6 AWG Wire Cable

AWG Overhead Service Cable Aluminium Duplex Triplex Wire Sizes PVCXLPE Insulated Single Core ABC Cable 6mm

Overhead insulated cables, overhead wires equipped with an insulating layer and protective sheath, are a new power transmission method between overhead wires and underground cables.

Product Application of 6 AWG Wire Cable

1. Overhead insulated cables with a rated voltage of 1kV and below are suitable for overhead power lines with a rated voltage of 0.6 / 1kv and below, and can be used as fixed laying or lead wires.

2. Overhead insulated cables with a rated voltage of 10kV and below are suitable for overhead transmission lines to transmit electrical energy. 10kV transmission line is the first choice for power grid construction and transformation.

3. Steel core aluminum core iron core overhead insulated cables with rated voltage of 10kV and below are suitable for overhead power distribution lines with AC rated voltage of 10kV and below.

STANDARS of 6 AWG Wire Cable
ASTM B-230 - Aluminum Wire 1350-H19 for Electrical Purposes
ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors
ASTM B-232 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399- Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
ICEA S-61-402-: Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy
ICEA S-66-524-XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy

Use characteristics:

1. Rated voltage: 1, 10KV

2. Long-term working temperature of the cable:

3. PVC, PE insulation<=70℃; XLPE insulation <=90℃.

4. The highest temperature of the cable conductor during short circuit (the longest duration does not exceed 5 seconds):

5. PVC insulation<=160℃; PE insulation<=150℃; XLPE insulation <=250℃.

6. Cable laying temperature >=-20℃.

Data Sheet:

Size

(AWG)

Construction

(NO./mm)

Diameter

(mm)

Jacket

Thick

(mm)

Over

Diameter

(mm)

Max.Cond

Resistance

(Ω/KM)

suqare

Millimetre

Ampere

30

11/0.08

0.30

0.55

1.20

331

0.05

0.80

28

16/0.08

0.36

0.55

1.30

227.2

0.08

1.25

26

30/0.08

0.46

0.55

1.50

123.00

0.14

3.50

24

40/0.08

0.61

0.55

1.60

97.60

0.20

5.00

22

60/0.08

0.78

0.55

1.70

88.60

0.33

8.73

20

100/0.08

0.92

0.55

1.80

62.50

0.50

13.87

18

150/0.08

1.19

0.55

2.30

39.50

0.75

22.00

17

210/0.08

1.33

0.80

2.70

21.40

1.00

31.00

16

252/0.08

1.53

0.80

3.00

24.40

1.27

35.00

15

336/0.08

1.69

0.80

3.10

20.02

1.68

42.00

14

400/0.08

1.78

0.90

3.50

15.60

2.07

55.60

13

500/0.08

2.06

0.95

4.00

12.50

2.50

65.00

12

680/0.08

2.48

1.00

4.50

9.80

3.40

88.40

11

800/0.08

2.59

1.00

4.60

7.38

3.96

100.0

10

1050/0.08

3.06

1.25

5.50

6.30

5.30

140.6

8

1650/0.08

3.75

1.50

6.80

4.20

8.29

200

6

3430/0.08

5.40

1.30

8.00

1.20

17.23

320

4

5000/0.08

6.50

1.75

10.5

0.84

25.0

120

2

7000/0.08

8.00

2.00

12.0

0.53

35.0

175