MY series aluminum housing 1 phase 2hp motor, with run capacitor, is made of selected quality materials and conform to the IEC standard. MY motors have features of good performance, low noise, little vibration and safety and reliable operation. The multiple of starting torque is 0.3-0.7 (MY), 0.45-0.75 (MYT). MY motors are suitable for the occasion where there requirements of starting torque is low and long-term continuous working, such as home electric appliances, pumps, fans, and recording meters, etc.
Product Detail
Motor Type: 1 phase 2hp motor
Output Power: 0.06 kW - 3 kW
Frame Size: IEC 56 - 100
Number of Poles: 2 and 4
Voltage: 220V / 230V / 240V (can design based on customers` requirements)
Frequency: 50 or 60 Hz
Protection Level: IP54 or IP55
Insulation Class: B / F
Cooling Method: ICO141
Working Duty: Continuous (S1)
Product Parameter (Specification)
1 phase 2hp motor

Production Features





Know More Us


Why Us

Service and Packing

About motor
Three points tell you how to detect the weak operation of single-phase motors
In this article, the editor of LIYUAN Motor tells you three methods for detecting weak single-phase motors.
1. When the single-phase motor cannot be started, first check whether the power supply voltage is too low, whether the switch, socket, and plug have poor contact; secondly, check whether the motor's rotor rotates flexibly, and whether it is "sucked" by the stator after power-on If so, you should check whether the end cap screws are loose and whether the rotor and stator are concentric. If the rotor bearing is worn and the lateral clearance exceeds the allowable value, it must be replaced.
2. If the motor can start after being switched by hand, but the operation is weak, usually the starting capacitor is damaged, just replace a capacitor of the same model.
3. Check whether there is a short circuit in the primary and secondary windings. The general rule between the main and auxiliary windings is that the resistance of the main winding is less than or equal to the resistance of the auxiliary winding; the resistance of the auxiliary winding is greater than or equal to the resistance of the main winding; the ratio of the sum of the resistances of the two windings is greater than the resistance of any winding. If this rule is not met, it means that there must be a slight short circuit between the primary and secondary windings. Usually this situation is that there is no trace of burnt in the appearance, and it is not visible from the end of the stator winding. The solution to this short-circuit situation is usually to replace the motor.
,