YCL series 5hp 1 phase motor is optimized from YC single phase capacitor start motor. The mounting dimension is fully conformed with IEC standard. YCL motors are superior motors delivering excellent torque enabling the toughest jobs to be handled with dependable ease and perform well in high voltage fluctuating regions. YCL series motors have the features of quiet operation, corrosion resistant, low vibration, low power consumption, long lifespan, low start current and good operation in hot environment. YCL 1 hp electric motor 1725 rpm series motor are used in the pumping, compressor, agriculture, farming, building service and manufacturing industry.
Product Detail
Motor Type: 5hp 230v single phase motor / 5 hp 240v single phase motor / 5hp 220v single phase motor
Output Power: 0.75 kW - 5.5 kW
Frame Size: IEC 90 - 132
Number of Poles: 2 / 4
Voltage: can be customized based on users
Frequency: 50 & 60 Hz
Protection Level: IP54 / IP55
Insulation Class: B / F
Cooling Method: IC411
Duty: S1 (continuous)
Use Conditions: Ambient temperature -15℃-40℃, altitude ≤1000 meters.
Product Parameter (specification)
5 hp 220 volt single phase motor
Type | Power | Current (A) | Speed (r/min) | Eff (%) | Power Factor CosØ | Tst/Tn | Tmax/Tn | Ist/In | |
KW | HP | ||||||||
4 poles | |||||||||
YCL132SB-4 | 3.7 | 5 | 22.1 | 1420 | 84.8 | 0.9 | 2.11 | 1.81 | 6.6 |
Production Features
Know More Us
Why Us
Service and Packing
FAQ
The motor is rated at 50Hz, can it run under the frequency conversion of 70Hz?
In this article, the editor of LIYUAN Motor will give you an analysis. Can a three-phase motor be rated at 50Hz and work at a variable frequency of 70Hz without overloading?
The three-phase motor is rated at 50Hz, which belongs to the ordinary three-phase AC asynchronous motor. It can only be used for frequency reduction or frequency increase within a relatively small frequency during V/F operation with a frequency converter, but the range should not be too large. , Otherwise, because many technical parameters of ordinary motors cannot meet the requirements, the motors will heat up and burn out. This is because some technical parameters and manufacturing processes of ordinary motors and variable frequency motors are completely different.
Their insulation grades are different.
Since frequency conversion motors have to withstand high-frequency magnetic fields, the insulation level is much higher than that of ordinary motors. The frequency conversion motor strengthens the slot insulation: the insulation material is strengthened and the thickness of the slot insulation is increased to improve the level of withstand high-frequency voltage.