ZEMIC BM14G load cell
Capacity:10t to 50t.
High accuracy.
Alloy steel construction.
Easy installation, reliable performance.
With OIML approval.
Detailed specifications BM14G4
| Accuracy class |
| OIML R60 C3 | OIML R60 C4 |
| Output sensitivity ( = FS ) | mV/V | 2.0 ± 0.02 |
| Maximum capacity ( Emax ) | t | 10, 20, 30, 40, 50 |
| Max.number of load cell intervals | nLC | 3000 | 4000 |
| Ratio of min. LC verification interval | Y = Emax / vmin | 8800 |
| Combined Error | %FS | ≤± 0.0230 | ≤± 0.0175 |
| Minimum dead load | Of Emax | 0% |
| Safe overload | of Emax | 150 % |
| Ultimate overload | of Emax | 300 % |
| Zero balance | of FS | < ± 1.0 % |
| Excitation, recommended voltage | V | 5 ~ 12 |
| Excitation maximum | V | 18 |
| Input resistance | Ω | 700 ± 7 |
| Output resistance | Ω | 700 ± 7 |
| Insulation resistance | MΩ | ≥5000 ( at 50VDC ) |
| Compensated temperature | °C | -10 ~+40 |
| Operating temperature | °C | -35 ~ +65 |
| Storage temperature | °C | -40 ~ +70 |
| Element material |
| Stainless steel |
| Ingress Protection (acc. to EN 60529) |
| IP68 |
| Recommended torque on fixation | Nm | - |
| ATEX classification (optional) |
| II1G Ex ia II1C T4 | II1D Ex iaD 20 T73°C | II3G nL IIC T4 |