Parameters of Toilet Brass Angle Valve

Model
Nature of the Manufacturer
Manufacturer
Product Category
Angle Valve
Place of Origin
XiAn City, ShanXi Province
Overview
Parameters of Toilet Brass Angle ValveHomeproductToilet Brass Angle ValveCategory Angle ValveTags Angle valve, CP valve, sanitary valve, shut-off valve, toilet valve, valveAn angle valve is a fluid regulating device used in plumbing and industry.It has inlet and outlet ports aligned at an angle with respect to each other,the most common angle being 90 degreesAdditional informationFinising:Polishing and ......
Product Details

Toilet Brass Angle Shut-off Valve

JX-0201

  • Angle Valve
  • Size 1/2″ X1/2″,1/2″ X3/8″
  • Zinc alloy handle
  • Brass Body With Chrome plated
  • Max work temperature; -10-120℃
  • The max working pressure; is 12 bar
  • Brass cartridge
  • Three million times open-off working is guaranteed
  • We can help you solve this problem because our triangle valve can match the G3 / 8 interface and the G1/2 interface. We are professional manufacturers. Would you please confirm the size of the water pipe by ourselves? Our angle valve is only suitable for G1/2 thread and 3/8 thread. G3/8 is smaller than G1/2 flow.

The inlet and outlet ports can be threaded to connect to galvanized steel and iron pipes or have compression fittings to connect to copper pipes. When an angle valve is used as a shut-off valve for residential plumbing fixtures, it is called an angle stop valve or simply an angle stop.

Inspection of Angle Valve Components.

 

Besides the inspection of the entire valve, its components can be inspected individually. This phenomenon is helpful in regard that it can help save the valve. Instead, only the leaked part can be removed. It can keep investing more money in purchasing a new angle valve. The most critical components of angle valves and their inspection procedure is listed below.

90-degree Turn brass water angle valve

Angle Valve Size

1/2″x1/2″,1/2″x3/8″

Valve pressure

120 bar

Valve Materials

CW602N, CW617N, Hpb59-1 brass, Lead-free brass

Valve Standards

BS2779,EN331,ISO228,DIN 259

Working Temperature:

From -5 ℃ To +90 ℃

Seat sealing Material:

PTFE

Handle Material:

Zinc Alloy

Thread connection:

ISO228,BS2779,DIN 259, ASME B1.20.-1983 Pipe Thread

Quality/valve Certifications

CE, ISO9001

Finish;

Polished and chrome plated and

Cartridge

Brass cartridge

Valve operator

Handwheel

Nickname

Outlet angle stop valve

O ring

NBR

Salt spray test

Acetic acid/ASS 24 hours
  1. Valve Seat: valve seat is an essential component of angle valves. During its inspection, you should check that the valve seating has no corrosion or rust. The valve seat must be doing well to make the angle valve function. Any problem in the valve seat can create leakage.
  2. Seal: We cannot deny the significance of seals in blocking fluid passage. It should be replaced every time you rebuild the valve. You should check that the seal is well fixed and secured for inspection into its sealing body groove. You should do it carefully. Because if it is loose, water can easily make its way out. Etch seals should be installed by facing them towards the upside. Facing downward can harm the etch but will not affect valve functionality.

The seal should be clean and free from any dirt. Make sure there aren’t any cuts or cracks in the seal body. If there is any such thing, replace it at once.

  1. Seal Disc: Seal disc ensures the durability of seal performance. It should be free from scratches and smooth by appearance. The seat face should not have any dirt, dust, or debris. If any such thing is present, remove it before applying a seal inside the valve.
  2. Stem: The stem is responsible for holding all the components of the angle valve in place. When you remove the stem for inspection, examine the threads along it. If you find any dings or wear, check them critically. As long as the wrenching surfaces are square, the stem has no problem. But the rounded surface needs to be changed.

Make sure the threads are lubricant and clean. You can pass a small thread across the surface to remove waste. Replace the stem in case of cracks or leakages. The stem area joining the body should be secure and scratch-free.

  1. Packing Screw: The threads of the packing screw should be fine and sharp. They should be free from scratches and defects. The packing screw is responsible for inserting the screw into the body.
  2. Body: Body inspection is essential for the overall performance of angle valves. Check for rust or corrosion in the seating area of the body. Remove the rust if possible. Yet, if you cannot, do it, discard the body, and apply a new one.
  3. Plug: The condition of the plug is essential to maintain a regular flow of fluid across the valve. The plug should not have any crossed thread. It should be in good working condition. You can also use a die to clean the plug. The thread gauge should not be oversized. If it is, replace the plug with an optimal tolerance plug.
  4. Outlet Flange: The outlet flange also plays a crucial time. Angel valves having outlet flanges should be adequately inspected. There should be no scars, and threads should not be crossed around. The structure should be in good condition. You should measure the Gauge size and threads if they are oversized. You can buy a new outlet flange to avoid any water leakage in such a case.