Normal House Heating Heat Pump

Model
Nature of the Manufacturer
Other
Product Category
Air Source Heating & Cooling Heat Pump
Place of Origin
City, Province
Overview
This series is splendid for domestic central heating and cooling with fan coil units.Cooling:Air-cooled chiller uses shell and tube evaporator to have water heat exchange with the refrigerant, refrigerant system absorption heat from water, the water cooling down, through the role of the compressor and bring heat to condenser, and then through cooling fan to outside.Heating: Air-cooled chiller uses fin type evaporator to extracts latent heat from the air and compresses it to amplify then the hot gas exchanges heat w......
Product Details

1,Copeland scroll compressor

2,High efficient tube in shell heat exchanger or Stainless steel brazing plate heat exchanger.

3,Automatic defrosting

4,Cooling in summer and heating in winter

5,Stable running, safe & reliable

6,No need install the cooling tower, easy to install, and convenient, suitable for lack water place and lack of space.

7,Low noise fan motor, excellent cooling condensation effect, stabilize the throttle body, excellent antirust processing

Normal House Heating Heat Pump


Optional:

Galvanized metal cabinet or stainless steel

R410a/R22/R407c/R134a refrigerant is available

50Hz,60Hz power is optional.

Normal Heating+Cooling Heat Pump
MODELXD-BKH03CXD-BKH04CXD-BKH05CXD-BKH06CXD-BKH10CXD-BKH16CXD-BKH20CXD-BKH25C
Power SupplyV/Ph/Hz220-240V/1Ph/50Hz380-415V/3Ph/50Hz
Ambient Temperature - 7℃~43℃
Heating Capacity (A7W35)kW913162128455875
COP (A7W35)W/W443.984.13.983.963.954
Cooling Capacity (A35W7)kW79131524395265
EER (A7W35)W/W2.82.852.822.722.782.752.812.82
Cooling/Heating
 Power Input
kW2.8/2.53.1/3.44.3/4.55.5/5.29.2/7.215.6/11.418/1522/19
Max.Working Current1522241214202225
RefrigerantR22/R407C/R417A/R410A
CompressorQTY11112222
TypePanasonic RotaryCompressor Scroll
Fan MotorQTY11222222
 Input power (kW)0.09*10.09*10.08*20.08*20.25*20.5*20.5*21.1*2
Heat Exchanger Water yield  (m3/h)1.5 2.0 2.5 3.0 5.0 8.0 10.0 12.0 
TypeHeat plate exchanger/ Tube in shell heat exchanger
ConnectorDN25DN25DN25DN25DN40DN50DN50DN65
Protection FunctionHigh and low pressure protection, Overload protection, Temperature protection Power phase sequence protection etc.
Machine size(L/W/H) mm878*430*7881018/285/13661018/285/13661156*456*13451450*710*11801580*1000*18002000*1000*21002000*1000*2250
Net Weight kg85132135160250400560680
■Cooling: Ambient temp.(DB/WB):35℃/24℃, Water temp.(In/Out) = 12℃/7℃
■Heating conditions A7/W35: outdoor air temp. 7℃ DB/6℃ WB, inlet water temp. 30℃, outlet water temp. 35℃.
■Due to product improvement, above datas are subject to change without prior notice, please take the rating plate as standard.