Milk Analyzer Ekomilk BOND are robust, reliable, automated multi-parameter milk analyzer providing rapid test results for: Fat, Protein, Solids Not Fat, Lactose, Density, Freezing point, Added Water, pH, Temperature and Conductivity in fresh and pasteurized milk (cow, sheep, buffalo, goat).One of the main advantages is the availability of ultrasonic processor for fast removal of air from the milk sample (available for Ekomilk Bond Standard only).This feature is mostly applicable for measuring of buffalo milk or at ......
Milk Analyzer Ekomilk BOND
Easy to use and to maintain, reliable and automated;
Fast and low cost analysis:
No acid or other chemicals are used;
Very small quantity of milk is required;
Short measurement time and low power consumption;
Multi-parameter milk analysis, high accuracy;
Digital re-calibration option for end user;
Short measurement time and low power consumption;
One year full warranty;
Power supply 220V/110V AC or 12V DC;
USB or RS232 Interface available;
Printout and collection of measurement data;
Ultrasonic Processor (deaerator) for fast removing of air from milk sample (available for Ekomilk Bond Standard only)
Environmental Conditions:
Ambient air temperature 15° – 30°C
Milk temperature 5° – 35°C
Relative humidity 30% – 80%
Electrical Parameters:
AC Power Supply voltage 220V +10%/-15% (Optional – 110V +10%/-15%)
DC Power Supply voltage 12V (10,5 V to 14,2 V)
Power Consumption 30W max
Mechanical Parameters:
Measuring Parameters |
Fat | 0,5% to 12% with accuracy ± 0,1% |
Solids non fat (SNF) | 6% – 12% with accuracy ± 0.2% |
Density | 1,0260 g/cm 3 – 1,0330 g/cm 3± 0.0005 g/cm 3 |
Protein | 2% – 6% with accuracy ± 0.2% |
Lactose* | 0.5% to 7% with accuracy ± 0,2% |
Freezing Point | from 0 to -1.000 °C with accuracy ± 0,015 °C |
Added water to milk | 0% – 60% with accuracy ± 5% |
pH | 0,00 – 14 pH with accuracy ± 0,02 |
Temperature | 0 – 50 °C with accuracy± 0,1 °C |
Conductivity* | 2 – 20 mS/cm with accuracy ± 1 % (18°C) |
Models |
PARAMETERS | BOND STANDARD | BOND TOTAL |
Fat | 0.5% - 12% ±0.1% | 0.5% - 12% ±0.1% |
Solids non fat (SNF) | 6% - 12% ±0.2% | 6% - 12% ±0.2% |
Milk density | 1.0260 g/cm3 - 1.0330 g/cm3 ±0,0005 g/cm3 | 1.0260 g/cm3 - 1.0330 g/cm3 ±0,0005 g/cm3 |
USB & RS232 interface | USB & RS232 interface
| USB & RS232 interface
|
Ultrasonic Processor (deairator) | Ultrasonic Processor (deairator) | no |
no | no | pH Measuring Module, Titratable Acidity |
Lactose *optional | Lactose *optional | Lactose |
Conductivity *optional | Conductivity *optional | Conductivity |
Indication for abnormal conductivity rate *optional | Indication for abnormal conductivity rate *optional | Indication for abnormal conductivity rate |
Integrated Thermal Printer *optional | Integrated Thermal Printer *optional | Integrated Thermal Printer |
Measuring time: 40s | Measuring time: 40s | Measuring time: 90s *optional 40s |