Welcome Customer !

Membership

SHANGHAI SHENKAI PETROLEUM & CHEMICAL EQUIPMENT CO.,LTD
Free Member ·1YRS
,
Other

Main Products: 石油化工仪器

Xwboo>Products

SK-2000FC Mud Logging Unit

Model
Nature of the Manufacturer
Other
Product Category
Mud Logging Unit
Place of Origin
City, Province
Overview
SK-2000FC Mud Logging Unit
Product Details

K - 2000 FC bus type positive pressure explosion-proof mud logging unit used explosion-proof CAN bus data transmission technology and national patent chromatograph and positive pressure explosion-proof technology, is suitable for offshore platform or environment neeed explosion-proof requirements, has been used in China international market such as Kazakhstan, Mongolia, Ecuador, etc.

●  Positive pressure explosion-proof technology, ensure the safety of the field working environment and staff
●  To provide geologist formation characteristics and the characteristics and evaluation of reservoir etc
●  Provide drilling engineer engineering data, achieve the goal of forecast and analysis of engineering accidents, improve the drilling efficiency, reduce the operation cost
●  Prediction of drilling engineering accidents

●  Power device
    FLP transformer
    Input voltage: 380V(480V、440V、220V)
    Input frequency: 50Hz
    Output voltage :380V 5%
    Output frequency:50Hz
 UPS Uninterruptible power supply
    Input voltage:220V 10%
    Input frequency: 35~65Hz
    Output voltage :220V 2%
    Output frequency:50 1Hz
    Supply time:≥15min
 Instrument housing security index: insulation resistance between phase line and grounding conductor in computer is greater than 2 MW, the instrument must be equipped with good grounding device.
●  Gas analyzer
 Component of nature gas analyzer
    Analytic circle:90s/3min
    Detect component:C1~nC5
    Component of nature gas Measuring range:30×10-6 ~1 mol/mol (CH4);
    30×10-6 ~30×10-2mol/mol (C2H6)。
    The minimum concentration of detector:30×10-6 mol/mol (CH4、C2H6);
    Total hydrocarbon Measuring range:50×10-6 ~1 mol/mol;
    Rapeatability error:±2.5%;
    Baseline shift:±0.1mV/h;
    Noise: 0.05mV;
    Resolution ratio:C1 and C2 retention time ≥5秒。
 Non-hydrocarbon component in natural gas analyzer
    Detect object:CO2;
    Minimum detectable concentration:CO2 0.1%;
    Measuring range:CO2 0.1%~99%;
    Baseline shift:measuring range 1%/7d;
    Rapeatability error:±5%。
●  Sensor
 pump stroke/table speed sensor:measuring range:0-1920 stroke /min,
 Rotary table torque sensor :measuring range:0~6MPa
 Stand pipe pressure sensor:measuring range:0~42MPa
 Casing pressure sensor:measuring range:0~68MPa
 Hook weight pressure sensor:measuring range:0~6MPa
 Drilling fluid temperature sensor:measuring range:0~125℃
 Density sensor:measuring range:0~3g/cm
 Electrical conductivity sensor:measuring range: 0~50ms/cm、0~300ms/cm
 Mud outlet flow sensor:measuring range:0~99% (relative flow)
 Liquid level sensor:measuring range: 0~5m
 Drawwors sensor:measuring range:0~999 times, set the hook position:0~50m
 H2S sensor:measuring range:0~100ppm, response time:T80<30s
●  Geological instrument
 Carbonate analyzer
    Measuring range:0~100% carbonate
    precision:1%
 Mudstone determinator
    Measuring range:1~3g/cm
    Minimum sample weight :0.05g
    Resolution:0.01g/cm
 Fluorscence analyzer
    Power supply:220VAC、50Hz
    Power:40W
    Thermal vacuum degasser
    Power supply:220VAC、50Hz
    Heating power :300W
    System vacuum degree:≤1.3KPa
    System sealing:after vacuum up to 1.3KPa, Visual vacuum table going down no more than 0.26KPa with 2 hours after partition;
    Volume of mud bottle:250ml
●  Electric degasser
 Working voltage :three phase 380VAC
 Power:370W
 Speed:1400rpm
 Explosion-proof grade :ExdIIBT4
●  Software system
 Windows 2000Serve or Windows;
 Conversion between metric and imperial;
 Real-time data acquisition, calculation, dynamic display of the rig, showed more;
 Automatic acousto-optic alarm and other functions;;
 Offer a variety of function module and a display screen;
 Provide remote transmission of data interface, meet the needs of different user needs