Wind off-grid power system consists ofthe wind turbine, controller, battery, wind off grid inverter and distributionsystem.Wind generate AC power through the wind turbine generator driven by thewind, and then converted to be DC power. The wind turbine off grid inverterwill inverte the DC power to be the right voltage , frequency and pure sinewave AC power to the local load. When the wind speed is very hight to causehigh dc voltage, the controller willstart beyond full energy by unloading, removing.
1. Using IGBT from Mitsubishi or Infineoncompany as the power components
2. Using American ATEMEL company microprocessoras figure controller
3. Perfect protection and warning functions
4. Circuit frame compact,Max. Efficiency≥92%
5. With wide input voltage range
6.RS232/485 communication,multi communicationinterface can be selected
7. Big-screen English LCD, perfect display,interface-friendly
Type | BNWA48 -1KD | BNWA220 -3KD | BNWA220 -5KD | BNWA220 -10KD | BNWA220 -20KD | BNWA220 -30KD | BNWA220 -50KD |
DC input | Input rated voltage | 48 Vdc | 220 Vdc |
Input rated current | 25.4A | 15.2 | 25.2 | 50.5 A | 101 | 151.5 | 252.5 |
Input DC voltage range | 42~90Vdc | 187~300Vdc |
AC output | Output rated capacity | 1.0 KVA | 3.0 KVA | 5.0KVA | 10KVA | 20kVA | 30A | 50A |
Output rated power | 0.8 kW | 2.4 kW | 4.0 kW | 8.0 kW | 16 | 24 | 4kW |
Output rated voltage and frequency | 220/230/240 Vac,50Hz |
Output rated current | 4.5 A | 13.6 A | 22.7 A | 45 A | 90.9A | 136.4A | 227.3 A |
Output voltage accuracy | AC220/230/240V± 3% |
Output frequency accuracy | 50/60 Hz±0.05 |
Waveform distortion | ≤3% |
Dynamic response (load 0↔99%) | 5% |
Power factor | 0.8 |
Overload | 150%,10s |
Crest factor | 3:1 |
Inverter efficiency | 82% | 90% |
Dielectric strength | 1500 VAC,1minute |
Noise(1meter) | ≤50dB |
Temperature | -25℃~+55℃ |
Humidity | 0-95%,No condensation |
Altitude(m) | ≤5000meters(when over 1000 meters according to GB/T3859.2 reduce the using amount) |
W*D*H(mm) | 482*405* 133 | 482*420*223 | 600*400* 700 | 500*500* 860 | 580*520* 1200 | 650*580* 1500 |
Protection | Input reverse connection protection, input under voltage protection, input over-voltage protection, output overload protection, output short circuit protection, overheat protection |