SIN-TRC400 Residual chlorine meter

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
Category: Chlorine meter Views: 38 Applications: Secondary water supply,Tap water ,Pool water,Water works,Agricultural drinking water
Product Details

Introduction


SIN-TRC400 residual chlorine meter has a built-in sensor, which has the characteristics of high measurement accuracy, fast response time and low maintenance cost. The residual chlorine meter outputs 4~20mA standard signal and RS485 signal, which can be connected to various regulators, and can be connected to two-position regulators, time proportional regulators, non-linear regulators and classic PID regulators according to requirements, which can be combined into various types. Residual chlorine control system.


SIN-TRC 400 Residual chlorine meter


Product

Residual chlorine meter

Model

SIN-TRC 400

Measure range

Residual chlorine: (0~5) mg/L

Temperature: (0.1~40.0)℃

Display

7 inch touch screen

Protective box size

Dimensions: 400mm×300mm×200mm

Window size: 155mm×87mm

Transmit output

(4~20)mA (optional)

Load resistance

≤750Ω

Communication

RS485, Modbus

Environmental humidity

≤95% no condensate

Power supply

220VAC

Ingress protection

IP43


SIN-ERC 400 Residual chlorine sensor


Measurement content

HCLO、CLO2

Measuring system

Microelectronics MEMS technology, special membrane structure

Measure range

(0~5)mg/L

Accuracy

When ≤0.1mg/L, the absolute error is ±0.01mg/L;

When ≥0.1mg/L, ±5% of the measured value or ±0.02mg/L (whichever is greater)

Resolution

0.01

Polarization time

When using for the first time, first pass water for 2 hours in chlorinated water, and then power on for half an hour.

Response time

Less than 30s after polarization is completed

Minimum conductivity

≥100us/cm, can not be used for ultrapure water

Operating temperature

(0~40)℃ (non-condensing)

Temperature compensation

Pt1000 with built-in integrated automatic compensation

Max pressure

4bar

Recommended flow rate ≥0.03m/s in flow cell
pH range (5~9) pH, below 5 will damage the membrane head
Maximum chlorine concentration ≥5ppm
Power supply Standard 24V DC±2V; optional 12V DC±2V
Power consumption 1.56W
Digital communication MODBUS RS485
Cable length Standard 3 meters, others can be customized
Probe weight 210g
Thread size NPT 3/4
Connection method 5-pin waterproof aviation plug
Moisture-proof material PVC and Viton® O-ring seals



SIN-TRC400 -RT1-O0-D1-I1-V1Description
SIN-TRC400------------
TypeRT1










(0~5)mg/L
Transmit outputO0









No
O1









(4~20)mA
CommunicationD1








RS485
Relay outputA2







2 relay outputs
Power supplyV1






220VAC(140~240VAC)




Wiring


1655888695593812.png