| Tester | High voltage detector | Host (current clamp) |
| Range | 0.0mA~1200A(50/60Hz automatic) | 0.0mA~20A |
| Insolution | 0.1mA | 0.1mA |
| Clamp Diameter | φ50mm | φ7.5mm |
| Test Accuracy | ±2%±5dgt | ±0.5%±5dgt |
| Sampling Speed | 2 times/second | |
| Function | High-low voltage current transformer primary and secondary loop current, transformation ratio, polarity, phase, and on-line test; current and voltage ratio on both sides of transformer; on-line test; load current test | |
| Transmission type | Wireless transmission, straight line transmission distance 30m | |
| Shift gear | Automatic shift | |
| Power | DC6V 7# Alkaline battery(1.5V AAA×4) | DC7.5V 5 # Alkaline battery(1.5V LR6×5) |
| Test mode | Clamp CT | |
| Meter Dimension | 87X37X262mm(W/T/H) | Host::w100X35X204mm(W/T/H) |
| Current clamp: 42X20X137mm(W/T/H) | ||
| Display mode | LCD:128dots×64dots Blue screen backlight function, suitable for dark places | |
| LCD Size | 62mm×44mm | |
| Ratio | Three kinds of transformation ratio display: (The primary and secondary circuit actually measured the current transformation ratio; the conversion ratio of the secondary circuit 5A; 10kV-YY transformer conversion ratio of 10kV/380V), the maximum ratio of 1:10 million | |
| Line voltage | Line test with insulation sheath below 60kV or bare wire current test below 35kV (must operate with insulation rod) | |
| Lead wire length | The lead wire of the current clamp 2 meter | |
| Weight | Total weight of instrument:3.1Kg(including insulation rob and instrument bag) | |
| High voltage detector:370g(including battery) | ||
| Host:409g(including battery) | ||
| Current clamp:180g | ||
| Data interface | USB transmission | |
| Overflow display | Over-range overflow function: "OL A" symbol display | |
| Data storage | 500 groups, press HOLD key to hold data, MR symbol display, press HOLD key to cancel hold | |
| Data review | Long press HOLD button to enter data review mode | |
| Data is full | Data full function: "FULL" symbol display | |
| No signal instruction | "NO SIGNAL -----" is displayed when the host does not receive the transmission signal | |
| Automatic shut-down | About 15 minutes after power on, the meter will automatically shut down | |
| Battery voltage | When the battery voltage drops to 5.2V, the low-power indicator lights to remind you to replace the battery | When the battery voltage drops to 5.2V, the battery voltage is low symbol to remind to replace the battery |
| Insulated rod | Five section insulation rods (5 meters in total) | |
| Insulation strength | AC 60kV/rms | |
| Line test | Line test with insulation sheath below 60kV or bare wire current test below 35kV (operate with insulation rod) | |
| Working temperature | -10℃~40℃ | |
| Storage temperature | -10℃~60℃ | |
| Relative humidity | 0℃~31℃≦75%,31℃~40℃≦50% | |
| Suitable for safety regulations | IEC1010-1、IEC1010-2-032、pollution level 2、CAT Ⅲ(600V) IEC61326(EMC standard) | |
| W/T/H: |
| High voltage detector | 1PC |
| Host | 1PC |
| Current clamp | 1PC |
| Insulation rob | 1SET(total 5 meters) |
| Instrument bag | 1PC |
| Battery | High voltage detector:7#1.5V alkaline dry battery 4PCS Low voltage hose:5# 1.5Valkaline dry battery 5PCS |
| Data wire | 1PC |
| Manual, certificate | 1SET |