Overall Screened Armoured Lead Sheath PE Insulated Instrumentation Cable
Standards
1. Reference Standard: BS5308-1
2. Rated voltage: 300V
3. Recommended bending radius:
18 x Cable Outer Diameter (during installation)
12 x Cable Outer Diameter (after installation)
Applications
Generally used within industrial manufacturing plants for communication, data and voice signal transmission and also for the interconnection of electrical equipment and instruments, typically in petroleum industry. They are generally designed where a greater degree of mechanical and chemical protection is required or direct burial at a suitable depth.
Characteristics
1. Conductor with high quality copper, low signal transmission attenuation
2. Insulation material for high-quality PE, anti-aging, low-temperature resistance, non-toxic and other characteristics can be customized.
3. Sheath material for high-quality PVC, anti-aging, wear resistance, low-temperature resistance, waterproof, anti-oil, anti-chemical corrosion, non-toxic and other characteristics can be customized.
4. The galvanized steel wire armor provides excellent protection.
5. Overall screened with aluminum foil, effectively blocking the external electromagnetic interference.
6. The lead sheath brings an enhanced resistance to aromatic hydrocarbons.
| Nominal CSA (mm2) | Max. CR @ 20℃ | Approximate Current Carrying Capacity | Max. Capacitance C-C (O/A SCR) | Inductance @ 1kHz (mH/km) | L/R Ratio @ 1kHz (μH/Ω) |
| 0.50 | 38.4Ω/km | 2~3.5 A | 82pF/m | 1.00 | 13.7 |
| 0.75 | 24.5Ω/km | 3~7.5 A | 89pF/m | 0.98 | 20.0 |
| 1.00 | 18.1Ω/km | 4~10.0 A | 98pF/m | 0.97 | 27.7 |
| 1.50 | 13.6Ω/km | 5~13.1 A | 110pF/m | 0.95 | 36.5 |