Vacuum pressure alternating test stand
Vacuum pressure alternating test stand
Product parameters:
1 vacuum pressure range: -50kpa to +100kpa
2 alternating frequency: 0-0.2Hz can be set arbitrarily
3 ambient temperature range: -40-150 DEG C
4 humidity range: 30 ~ 98%
5 humidity deviation: + 3%RH (= 75%RH) + 5%RH (75%RH);
6 heating speed: 25 - 150 C = 45min (nonlinear, about 1.5 DEG /min)
7 cooling speed: 25 DEG C, -40 = 30min (nonlinear, about 1 DEG /min)
8 pressure holding time range: 1S-9999Min can be set arbitrarily
9 tested products: pipes, tanks, tanks, filters and similar products
10 computer centralized control acquisition and processing test data
Two, working principle
1, independent vacuum pulse
2, independent positive pressure pulse
3, positive pressure and vacuum pulse
Three, can realize the function
1. The equipment can be set in the range of -50kpa to +100kpa; it can be set to the number of pressure alternating cycles, and set the number of tests. And can read more than 1000000 of the cycle.
2, the test medium for air.
3, the vacuum pressure value should be displayed on the display screen in real time. And can be stored in the database in order to check the historical data.
4, the microcomputer control function, at the beginning of experiment can automatically exhaust, test process can be arbitrarily set pressure and time; parameter test data and curve of real-time display and can automatically save the storage of test results, and it can print the test report; equipped with color printer (A4) and OFFICE office software compatibility, networking, programmable test report.
5, the control system and test system should be placed separately, the two are about 5 meters apart, the middle through the transmission line connection.