Inner Erosive Test Bed
The device is used in inner erosive test of aluminum and the aluminum water-cooled oil cooler tank which simulates engine coolant working condition, hereinafter referred to as “inner erosive test bed"; it will provide test evaluating condition for the sample (aluminum water tank and Water-cooled oil cooler) according to ASTM D2570、QC/T468-2010、GMW14167 、GMW15737、SANHUA PHEX Technical Specification test rating conditions for conducting the required tests.
1. Basic Parameters of Inner Corrosion Test Bed:
1)Sample box size :1500 (L) × 1000 (w) × 1000 (H);
2)Flow Quantity of the Corrosive Liquid (10 (0.6t / h) until 666l/min (40t / h) which can be adjusted arbitrarily;
3)Temperature of Corrosive Liquid (Room temperature until 125℃ which can be set arbitrarily, the precision is ± 2℃);
4)Heating Up Rate (1℃ ~ 2℃ / min);
5)Pressure Inside the Erosive Cavity: 0.05-0 .5 Mpa (it can be adjusted arbitrarily);
6)Number of Test Pieces: it can provide 1-3 sample for test simultaneously, the maximum volume: 20L;
7)Starting Time Record of the Device :accurate to the second, it can be set arbitrarily in 9999 hours;
8)The Record of Circuit Working Time for the Device :accurate to the second, it can be set arbitrarily in 9999 hours;
9)Stop Running Time of the Device: Accurate to the second, and it can be set arbitrarily in 9999 hours;
10)Mode of Control: Full-automation control of the computer or the touch screen.
2. Security (Alarm) System
1)The device will alarm and stop if the liquid inside the test box is much lower;
2)The device will alarm and stop if it is over-temperature;
3)The device will alarm and stop if the door of the test box is open;
4)The device will alarm when it leaks and automatic shutdown;
5)The device will alarm and automatic shutdown when the test is over.
3. Other
1)With test after test before the test piece to install the exhaust device;
2)The liquid Tank is located under the test samples which ensure it is convenient to unload;
3)The device is totally closed and cabinet type structure which is convenient maintenance for the device and dismounting for the components;
4)The part which contact with the corrosive liquid adopts stainless steel; the heat insulator is wrapped outside the device;
5)PID control is used in the temperature control.