Welcome Customer !

Membership

Tianjin Getes Testing Equipment Technology Development Co., Ltd
Free Member ·1YRS
,
Other

Main Products: 试验机

Xwboo>Products

Tianjin Getes Testing Equipment Technology Development Co., LtdFree·1YRS

  • E-mail

    techhb@126.com

  • Phone

    400-666-7199

  • Address

    NO. 14 ,Fengze Road, Zhangjiawo industrial park,xiqing District,Tianjin

Contact Now

Gas Pulse Test Bed for Intermediate Cooler

Model
Nature of the Manufacturer
Other
Product Category
Auto parts testing equipment
Place of Origin
City, Province
Overview
Gas Pulse Test Bed for Intermediate Cooler
Product Details

Gas Pulse Test Bed for Intermediate Cooler

The test bed may complete the alternating pressure of gas in air intermediate cooler and turbine booster hose pipes. The test medium is high pressure compressed air. The test bed adopts industrial computer for centralized control with Chinese interface to input test parameters to perform real-time monitor and control. The functions of data and curve storage and print are also provided. It also has the function of gas tightness inspection (differential pressure method) before and during the test, to judge the leakage during the test (judgment of peak value of pressure target) as well as automatic switching function of multiple pressure cycle modes. The function and test parameters are in line with relevant standard and technical specification in QCT 828, GMW15803 and GMW16153. Gas pulse test and airtight and proof pressure test may be conducted for pressure containers and pipes.

1. Technical parameters

1)Test pressure: 0.1~0.5MPa;

2)Gas alternative frequency: 0~2Hz;

3)Pulse test medium: high temperature compressed air;

4)Waveform adjustment: sine wave, trapezoidal wave and triangular wave;

5)Environmental temperature of the test machine: -40~180℃, with independent refrigerating system;

6)Medium temperature scope: 90~300℃.

2. Function and characteristics

1)PC computer system is used for data acquisition, process control and data processing;

2)The interface displays test data dynamically and draws the real-time time-pressure wave;

3)The computer saves test data automatically and generates test report and prints it;

4)The temperature-time curve, medium temperature-time curve in the work chamber is may be provided. The temperature value of every point on the curve may be inquired. The temperature of work chamber, lowest and highest value of the medium temperature may be displayed during the test;

5)Having the function to set error proportion of upper and lower limit of work pressure and count the times exceeding the permissible error proportion during the test;

6)Data acquisition software of U.S. NI Company is used for monitoring. The test data is recorded and stored continuously. The historical data and corresponding waveform of any time frame may be inquired and exported, as well as other real-time data including temperature-time curve. Test report may be produced and print it.

3. Safety protection

1) Test is not performed when the door is open; with safety glass reinforced with network wire, emergency button and automatic shutdown at the time of fault;

2) The alarm apparatus is provided when the medium chamber is designed. When the pressure reaches the lower limit, the whole machine cannot start or heat;

3) With the function of over temperature, over pressure, audible and visual alarm for leakage and emergency shut down;

4)Failure protection function: the pressure drops quickly after the part fails so that there is no high pressure gas to squirt continuously to ensure personal safety to the greatest extent. It is also provided with the function of automatic shutdown for protection after the test parts are damaged. The test chamber is provided with safety protection measures to avoid that gas will spray out due to sudden failure of test chamber and the test chamber is damaged.

Similar Product Recommend