Welcome Customer !

Membership

Shanghai high-end pump manufacture Co., LTD
Free Member ·1YRS
,
Other

Main Products: 泵

Xwboo>Products

2 X the two-stage spin chip vacuum pump

Model
Nature of the Manufacturer
Other
Product Category
Vacuum pump spray water injection unit
Place of Origin
City, Province
Overview
2 X the two-stage spin chip vacuum pump
Product Details

Products overview:

2 X series rotary chip vacuum pump, its structure is to use to be eccentric stator and rotor cavity in the rotor slot sliding and centrifugal force to borrow spring tension stator's inner surface of two pieces of spin, stator space into two working chamber, the volume on one side of the gas expanding inhaled, the other side volume shrink, gas compression to the atmospheric pressure by exhaust valve eduction, the operation to repeat every second.

2 X screw vacuum pump for double level chip structure, when inhaled at high pressure, high and low level cavity and exhaust, suction pressure is lower, breathe in the mouth by gas into the senior cavity, the compression of the airway in the wall after through into the lower chamber, once again, compression, from a lower exhaust valve eduction. When the pump valve with gas town, allow surking contains a small amount of water vapor, such as sexual steam gas. 2 X-2 A, 4 A, 8 A, 8, 15 pump up and down for eccentric structure, high and low level by convex groove of the coupling rotor rotating form. 2 X-30 A, 70 A pump for the eccentric structure, low rotor set in the senior rotor shaft to the rotation of the form, and using the pump housing the heart cooling, cooling with pump temperature is low, limit the total pressure the characteristics of low.

Purpose and use scope:

1, 2 X pump is used for surking air sealed containers for one of the basic vacuum equipment. Can be used separately, but also as a booster pump, diffusion pump, molecular pump and former level pump. Can be used in vacuum smelting, vacuum welding, vacuum macerate, coating, vacuum casting, vacuum drying and chemical pharmaceutical, electric vacuum device, and other industrial vacuum homework.

2, pump can be in the environment temperature 5 ~ 40 ℃ scope and import pressure under the condition of less than 1330 pa, allow long-term work continuously.

3, pump does not apply to smoke too much oxygen, poisonous, explosive, corrosive action of metal have to pump oil, the chemical reaction, and contains grains of dust gas, also does not apply to gas from one container transportation to another vessel, as pump use.

4, pump in the 6000 Pa pressure to import under the pressure of the continuous work time can not be more than three minutes, lest injection or bad lubrication pump damage caused.

Installation instructions:

1, pump should be installed in the ground strong strong places, and around a sufficient room shall be maintained, facilitate inspection, maintenance, maintenance.

2, under the pump should keep foundation level, the base in four Suggestions shock or bolts rubber mat pouring installation, ensure the pump smooth operation, little vibration.

3, pump and pipeline system connection should be reliable seal, the little pump can use metal pipeline connection gasket using oil resistant rubber, the little pump can be adopted vacuum hose connection, pipe diameter is not less than the pump breathe in diameter, and require pipeline short and less elbow. (welding line should be removed when the pipe welding slag, forbidden welding slag into the pump chamber.)

4, in the pipeline connection, the user can in the pump the intake valve installation and vacuum plan above, can always check the limits of pump pressure.

5, according to the motor power connection sign provisions, and ground and installation specifications of the fuse and appropriate thermal relay.

6, pump electricity the test run, must take the motor belts, sure the pump to comply with regulations direction may be put into use, in case the pump reversal injection. (to press shields directions)

7, for the cooling water pump, according to the rules, through to the cooling water.

8, such as pump inlet install solenoid valve, valve and pump action should be at the same time.

9, when pump discharge gas to influence the work environment, the vent assembling piped from or assembling oil mist filter.

Instructions:

1, closed above the pump valve

2, cooling water pump on the cooling water.

3, nearly provisions to hand dish pulley few laps to pump oil into fuel tank in the cavity inside, make sure start is not easy to gush of oil. (especially in winter, oil, start load sticky, so please note).

4, start motor, the pump to start the operation, and observe the oil window, check the oil level. Oil position should be in the oil standard center, oil level on the high side, can cause injection; Oil level is low, can cause bad lubrication, the pump pressure can not reach the limit factory index.

Come on, put oil pump position as shown in the "sign. Slowly open pump valve of the above, the system began to work.

When not working pump, oil window can hardly see the oil, into the pump body, oil pump running with a standard.

5, cooling water of the inlet water temperature with no more than 30 ℃ advisable, inlet and outlet water temperature difference with no more than 3 ℃ advisable.

6, when environment temperature below 5 ℃, should will pump out oil heating to 15-30 ℃ to start work in the pump.

7, pump temperature to the oil temperature minus the environment temperature more than 40 ℃ advisable, otherwise should strengthen the ventilation cooling or increase the cooling water flow.

8, inlet temperature higher than 40 ℃ and make the pump temperature is high, the measures should be taken to cooling air.

9, when inhaled to pump oil or gas pump have influence, in mouth pump before should hold a a suitable filter device.

10, when the pumped in addition to contain a small amount of the gas can, start pump valve should be open gas town work half an hour, can prolong pump oil use time.

11, when the pumped in addition to containing particles of dust and gas pump before in mouth should hold a a suitable filter.

12 and close before the pump, you should turn off the top of the pump valve and isolation system, then stop the pump, then tighten the gas town valve, to prevent oil from leaking, and finally close cooling water. Winter has frozen occasions should put in net pump cooling water, in case of unrelenting frosty pump chamber.

Note: this series of pump pressure is to point to the limit of the pump wouldn't pick up any vessel, pump temperature is up to stable, use compressed type vacuum pump inlet in the project of the lowest point of the stable pressure. Limit the total pressure is only for reference. Generally, the single pump running half an hour will reach the limit stress.

Maintenance and maintenance:

1, often check the oil a position, is not in conformity with the provisions must be adjusted when with requirements. To pump operation, oil level to oil standard center shall prevail.

2, often check oily situation, found that the oil metamorphic should change in time new oil, ensure the pump working normally.

3, oil time limit according to actual use condition and can meet the performance requirements etc consideration, the discretion by the user. General new pump, smoke in addition to clean and dry gas, it is suggested that the work 100 hours oil again. To see black metal powder in oil, later can be appropriately extended oil deadline.

4, usually, pump working 2000 hours after should carry on the overhaul, check Jue rubber seal aging degree, check the exhaust valve slice is cracking, cleaning the precipitation in the valve plates and the dirt from the exhaust valve seat. Clean the whole pump chamber parts, such as the rotor, rotary piece, spring. General use gasoline cleaning, and drying. A kind of rubber after cleaning with dry cloth to wipe dry.

When cleaning assembly should be gentle with careful collision.

5, the conditions in cleaning up to the same, ensure smooth lines.

6, the new assembly should be carried out after the trial run, general must empty operation and replace the 2 hours oil twice, because when cleaning will have a certain amount of the pump to volatile, stay working normally, and then put into normal work.

7, this series pump oil by SY1634-70 1 # vacuum pump oil.

Pump structure: