DCU9010XPN network type two controllers
Compatible with a variety of front-end input:
Support Wiegand 26Bit, Wiegand 27Bit, Wiegand 32Bit format input; compatible ABA (second track); biometrics technology, fingerprint identification technology, IC card, password keyboard, magnetic watermark input device, and is adaptive controller automatically detects the input front end.
The controller system capacity and feature set: Each controller supports 60,000 cardholders increased RAM memory, expandable to 80,000 cardholders.
Information recording: recording time access to relevant information for each person and out of time, each controller can store 60,000 out of an event or an alarm event buffering.
Interlock: Interlock plate can be set for each point linkage.
Linkage alarm: through external switch signal to the input terminal, when a switch signal input terminal detects a change of state, the controller sends a signal relay instructions. If a fire, the controller receiving fire switch signal to the relay to drive electric locks, magnetic locks, and all open.
Communication: TCP / IP communications.
Identification: determining whether the cardholder has access rights to the door, into the variety of programmable controllers, Calgary 4. Password access, eight super password to access card door cards will also support multi-regional anti-trace detection settings.
Various door state working methods: door normally open, normally closed doors, open the door the first card reader control, sleep control, security status.
Remote manual control at any point of the door
Memory 256K EPROM, 1024K RAM
Real-time clock, the door opened out alarm 1-255 sec, programmable
Multiple system board condition monitoring and self-test
Real-time monitoring: the current state of the door every online online monitoring, data errors, network anomalies and system reset, the control box opened illegally.
Dynamic voltage protection: All inputs, outputs with dynamic voltage protection, all with instantaneous relay output overvoltage protection.
Power supply: Rated voltage DC12V and DC5V (± 30%) two power supplies, rated current <0.3A
Input parameters: dry contact switch input
Output load parameters: Working voltage DC≤12V, operating current ≤5A
Working environment: Temperature 0 ℃ ~ 70 ℃, humidity 0 to 90%
Reading sensor Interface: Provides TTL level signal, 12V DC, 150mA power supply sensor reading
Reading sensor connection cable: 8-core shielded twisted pair cable, 24AWG, up to 200 m
Within five years to save the memory controller lithium battery to keep the memory and time in the controller setting data retentive time more than 90 days
Output and input:
2 set of standard card reader input port
2 set of standard door status input terminal
2 groups out request button input terminal
2 Group C type relay electric lock output terminal
2 output terminal group expansion
Dimensions:
DCU9200 control PCB board
------ 200mm x 105mm x 25mm
DCU9200 floor
------ 240mm x 125mm x 30mm
Carton size
------ 360mm x 275mm x 80mm
Carton Material: Steel and spray