EX-810 Strain Data Logger Series
Model & Channels
| Model | Channels |
| EX-810-8C-A | 8 Channels, max measuring channels 64,Supported:120Ω |
EX-810-16C-A
| 16 Channels, max measuring channels 64,Supported:120Ω
|
EX-810-24C-A
| 24 Channels, max measuring channels 64,Supported:120Ω
|
EX-810-32C-A
| 32 Channels, max measuring channels 64,Supported:120Ω
|
EX-810-40C-A
| 40 Channels, max measuring channels 64,Supported:120Ω
|
EX-810-48C-A
| 48 Channels, max measuring channels 64,Supported:120Ω
|
EX-810-56C-A
| 56 Channels, max measuring channels 64,Supported:120Ω
|
EX-810-64C-A
| 64 Channels, max measuring channels 64,Supported:120Ω
|
EX-810-4C-B
| 4 Channels, max measuring channels 32,Supported:120/350Ω
|
EX-810-8C-B
| 8 Channels, max measuring channels 32,Supported:120/350Ω
|
EX-810-12C-B
| 12 Channels, max measuring channels 32,Supported:120/350Ω
|
EX-810-16C-B
| 16 Channels, max measuring channels 32,Supported:120/350Ω
|
EX-810-20C-B
| 20 Channels, max measuring channels 32,Supported:120/350Ω
|
EX-810-24C-B
| 24 Channels, max measuring channels 32,Supported:120/350Ω
|
EX-810-28C-B
| 28 Channels, max measuring channels 32,Supported:120/350Ω
|
EX-810-32C-B
| 32 Channels, max measuring channels 32,Supported:120/350Ω
|
Features:1、Modular approach, 8chs/Modular ,Maximum extension to 32 /64channels2、Connected through the USB interface, long-term data are stored on the host hard.3、The acquisition of signal 120 /350ohm strain gages.4、The maximum sampling rate of 10KHz (64-channels simultaneous sampling).5、Action menu in the dialog box form of the Chinese language interface is simple and fast.6、Combined with strain gauges in the international test standard Intel standards and IPC-9704 standard, a key fully automatic generate reports and judgments "Pass" Or "Failed"Parameters:◆ Single module Number of channels: 8 analog input channels◆ Maximum sampling rate: 640KS / s / chassis◆ Sampling modes: multi-channel simultaneous sampling◆ ADC resolution: 24◆ Supported strain Gage Resistance: 120/350Ω◆ Wheatstone bridge type: 1/4 bridge◆ Conversion accuracy: 3.5062nV/V/LSB◆ Accuracy gain error: 0.02% (calibrated conventional measurement conditions 25 ° C ± 5 ° C)◆ Full-scale range: ± 29.4mV / V (+62500 uE/-55500uE)◆ Between terminals Overvoltage protection: ± 30V◆ Stability: Gain drift 6ppm / ℃◆ The Chassis Interface Type: USB2.0 high speed input◆ Power supply: 11 to 30VDC, 220VAC◆ Operating Temperature: -40 ℃ ~ 70 ℃, Operating Humidity: 10% ~ 90% RH, non-condensing◆ Storage Temperature: -40 ° C to 85 ° C, storage humidity: 5% to 90% of RH, non-condensing◆ Protection class: IP 40