Types | UCAM-60B-AC AC only UCAM-60B-DC DC only |
TEDS | Interface: IEEE 1451.4 Mixed Mode Transducer Interface Class 2 Applicable sensor: Should have information written in accord-ance with IEEE template No. 33; cable length should be 30 m or less |
Scanning Speed | Notes: 1. High-resolution mode and high-speed mode are selectable for dedicated scanners only. 2. High-resolution or high-speed mode is available only with full bridge system. |
File Conversion | CSV conversion |
Coefficient Calculation | Multiplication by calibration coefficients, calibration by TEDS, conversion of measured values to physical quantities, scaling and correction. |
Self-diagnosis Functions | Checks display, printer, bridge excitation, lead-wire-off, input/output resistance, insulation resistance, mode, etc. Checking of input/outut resistance and mode is availabe only for dedicated scanners. |
Automatic Measurement Functions (Trigger Measurement) | A relative value (Certain changing quantity) or an absolute value triggers measurement. In addition to the usual trigger function, a variable trigger function is provided with which the trigger value changes at each step during measurement. With this special function, a trigger value and the number of measurement times (Repeat times) under the trigger condition can be registered for each step to perform a series of automatic measurements in the order of steps. |
Automatic Measurement Functions (Interval MeASUREMENT: ) | Measurement is automatically performed at preset time intervals. |
Automatic Measurement Functions (Trigger Interval Measurement) | Combination of trigger measurement and interval measurement. |
Channels | Max. 30 with dedicated scanners Max. 1000 with external scanners connected |
Measuring Functions | Initial: Initial values are measured and stored in internal memory (Except for temperatures measured by civil engineering transducers with temperature measuring function). Original: Raw values are measured without subtraction of initial values. Measure: Initial values are subtracted from original values (Except for temperatures measured by civil engineering transducers with temperature measuring function). Easy Measure: Auto zero balancing function is activated. Note: The selected function is applied to all channels. Coefficient |
Measuring Targetss | Strain gages, strain gage transducers, civil engineering transducers with temperature measuring function, DC voltage-output or DC current-output instruments, potentiometer sensors, thermal sensors (Thermocouples and platinum resistance thermometer bulbs) |
Units | 59 units |
Operation Modes | Real-time, Monitor, and Automatic |
Standard Accessories | AC power cable P-18 with 2-pin conversion plug CM-39 (AC-operated version) DC power cable P-76 (DC-operated version) Recording paper UCAM-60A-RP (1 roll for UCAM-60B only) Screwdriver Spare fuse CD-R (Instruction Manual) |
Optional | Recording Paper UCAM-60A-RP (10 rolls/pack) |
Sacnning Speed | USB-70B (Standard Mode only) : Standard Mode (50 ms/channel) Besides these, the following speeds can be set for each individual channel: 0.28 s, 0.5 s, 1 s, 2 s, 5 s and 10 s |
Auto Measuring Functions (Trigger Measurement) | Trigger channel : 1 desired channel |
Automatic Measurement Functions (Trigger Measurement) | Trigger Value : A desired real number of 6 effective figures or less Reference |
Auto Measuring Functions (Trigger Measurement) | standard Value : Amount of level shift to determine the first trigger value (Selected from the same range as for the trigger values) Repeat Times : 1 to 9999 (0 for infinite times) Measuring Steps : Maximum 15 |
Auto Measuring Functions (Interval Measurement) | Measuring Start Time : Year/month/day and hour: minute: second Interval setting: Days and hours: minutes: seconds (In a range of 00 and 00: 00: 01 to 99 and 12: 59: 59) Measuring Interval : Days and hours: minutes: seconds (In a range of 00 and 00: 00: 01 to 99 and 12: 59: 59) Repeat Times : 1 to 9999 (0 for infinite times) Available Steps : Maximum 15 |
Auto Measuring Functions (Trigger Interval Measurement) | Measuring Times : Max. 9999 Interval Time : Available in a range of 1 second to 99 days 23 hours: 59 minutes: 59 seconds |
Storage Functions | Built-in Memory : Internal memory, approx. 7 MB Exterior Memory : Flash ATA card (Optional); the capacity depends on the card. |
Sacnning Speed | Exclusive Scanning Unit (Standard Mode): : 50 ms/channel. Scanning speeds stated above are standard maximum speeds in respective modes. Besides these, the following speeds can be set for each individual channel: 0.28 s, 0.5 s, 1 s, 2 s, 5 s and 10 s Exclusive Scanning Unit (High-Conversion Mode): : 280 ms/channel (High-resolution mode) Note: Individually selectable for desired channels Exclusive Scanning Unit (High-speed Mode): : 20 ms/channel (High-speed mode), voltage, Current, only Potentiometer sensors |