Summary of the equipment
JFFG type automatic water filter is composed of water filter body, electric actuator, automatic control mechanism and sewage discharge mechanism. The automatic control mechanism is composed of a pressure difference controller installed on the water filter body, PLC, module, and electrical control box. A number of filter units are installed in the automatic water filter tank to work simultaneously. Each filter unit is backwashed one by one. The other filter units are still working to ensure continuous water supply. It has automatic filtering, automatic cleaning, and automatic drainage, and does not affect the normal water supply during cleaning and drainage. Electrical control adopts PLC programmable automatic control. It can also be controlled manually, and it is provided with excessively high differential pressure and over-torque protection of the sewage valve, which can realize unattended duty.
operating principle
When the automatic water filter is in the normal filtering state, the electric reducer does not start and the drain valve is closed. When a certain pressure difference is formed at the inlet and outlet of the water, the sewage valve opens, the electric reducer starts to drive the sewage fork pipe to rotate, and the washed filter screen units are connected to the sewage outlet respectively. The dirt attached to the filter screen is flushed with the clean water from the filter and discharged through the open electric sewage valve. Two control methods for cleaning and draining of automatic water filter: (1) Timed cleaning: The timed cleaning of the PLC programmable controller can be set to 1-99 hours, and the setting range of the washing time is adjustable from 1-10 minutes. When the PLC programmable controller is activated, the water filter The drain valve is opened, the reducer is started, and the water filter is used for cleaning and draining. (2) Differential pressure control cleaning: When the pressure difference between the front and rear of the water filter reaches the set value (0.025-0.04Mpa), the differential pressure control is activated, the water filter drain valve is opened, the reducer is started, and the water filter is cleaned Sewage. The two control methods of timing cleaning and differential pressure control cleaning work in parallel.

technical parameters
Filtration accuracy: from 4000 microns to 200 microns
Screen type: hole, wedge
operating pressure ≤ 1.0mpa (Special customizable)
operating temperature ≤ 95℃
power supply: 380V/50Hz
the control voltage is AC24V
cleaning method: filter cylinder one by one back wash
control mode: pressure difference, time, manual
cleaning time :10-200 seconds adjustable
technical specification sheet