Overview
HM-8000D Transformer Dielectric Loss Tester is a high-precision instrument, which can be applied to automatically measure electrical loss tangent () and capacitance of all kinds of high voltage electrical equipments on the spot of power plants, substations,laboratory, etc. The instrument is an...
Product Details
I.Summary


HM-8000D Transformer Dielectric Loss Tester is a high-precision instrument, which can be applied to automatically measure electrical loss tangent () and capacitance of all kinds of high voltage electrical equipments on the spot of power plants, substations,laboratory, etc. The instrument is an integrated structure with a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor. High voltage source inverter test generated inside the instrument, the transformer voltage for sample test. If the frequency is 50Hz、47.5Hz/52.5Hz、45Hz/55Hz、60Hz、57.5Hz/62.5Hz、55Hz/65Hz, the digital notch filter is used to avoid the interference of the power frequency electric field to the test, which solves the problem of accurate measurement under the strong electric field interference. At the same time, the utility model is suitable for the occasions that the generator is used for power supply after the power cut. The instrument with insulation cup can test the dielectric loss of insulating oil.


The Transformer Dielectric Loss Tester has the following characteristics:

·Insulation resistance test

The instrument integrates insulation resistance test module, which can test polarization index, absorption ratio and insulation resistance.

·Automatic measurement of LCR

Automatic inductance, capacitance and resistance measurement and angle display.

·Large LCD display

Simple operation, the instrument is equipped with a high-end full touch LCD screen, super touch interface, each process is very clear, the operator does not need additional professional training can be used. Click on it to complete the whole process of measurement, is a very ideal intelligent dielectric loss measurement equipment.

·Mass storage data

The instrument is equipped with a calendar chip and large capacity memory, the test results can be stored in chronological order, at any time to view the history, and can print output.

·Multiple test modes

The instrument can use high pressure, high voltage, standard, standard, positive connection method and reverse connection method, self excitation method and other methods can do testing; high voltage in standard high voltage conditions (greater than 10kV) dielectric loss.

·CVT test step in place

The instrument can also test the full sealed CVT (capacitor voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C1, C2 simultaneous test. The instrument can also test the CVT ratio and voltage angle difference.

·do not dismantle the high-voltage lead measurement CVT

The instrument can accurately measure the dielectric loss and capacitance of CVT without dismantling the

CVT high voltage lead.

·CVT reverse shield method for measuring C0

The instrument can be used to measure the dielectric loss and capacitance value of C0 on the upper end of CVT.

·High speed sampling signal

The inverter and sampling circuit of the instrument are all controlled by digital, and the output voltage is adjustable continuously.

·Multi protection security

The instrument has many protection measures, such as input voltage fluctuation, output short circuit, over voltage, over current and temperature. The instrument also has the grounding detection function to ensure that no grounding equipment is not allowed to boost.

·Automatic measurement of LCR

Automatic inductance, capacitance and resistance measurement and angle display.

·Four channels simultaneous test

The positive connection method can be used to test the dielectric loss values of four tested samples at the same time.


II.Working principle


In the AC voltage, the dielectric to consume part of the energy, this part of the energy will be converted to heat energy loss. This energy loss is called dielectric loss. When AC voltage is applied on the dielectric, the dielectric between voltage and current in phase difference angle psi, delta psi is called the dielectric loss angle tangent TG delta delta is called dielectric loss tangent. TG delta value is used to measure dielectric loss parameters. The instrument measuring circuit includes a standard circuit (Cn) and a test loop (Cx), as shown in Figure 2 - 1. The standard circuit is composed of a built-in high stability standard capacitor and a measuring circuit. Measurement line sampling resistor with pre amplifier and A/D converter. By measuring circuit are respectively measured by standard test and loop current loop current amplitude and phase difference, then the digital signal processor using digital real-time acquisition method, obtained through vector operation test of capacitance and dielectric loss tangent value. The anti-interference measures have been adopted in the instrument to ensure the accurate measurement under the interference of external electric field.

Schematic diagram

picture-1-


III.Main technical parameters


1

Use conditions

-15℃∽40℃

RH<80%

2

Anti-interference

Frequency conversion

3

Power

AC 220V±10%

Allowable generator


4

High output

0.5KV∽12KV

Every 0.1kV

Precision 2%

Maximum current

165mA

Capacity 2000VA

5

Self-excited power

AC 0V∽50V/15A

45HZ/55HZ 47.5HZ/52.5HZ

55HZ/65HZ 57.5HZ/62.5HZ

Automatic double frequency

6

Resolving power

tgδ: 0.001%

Cx: 0.001pF

7

Precision

△tgδ:±(Reading*1.0%+0.040%)

△C x :±(Reading*1.0%+1.00PF)

8

measuring range

tgδ

Unlimited

C x

15pF < Cx < 300nF
12KVCx=(Cx1+Cx2+Cx3+Cx4)< 42 nF
5KVCx=(Cx1+Cx2+Cx3+Cx4)<150 nF
1KVCx=(Cx1+Cx2+Cx3+Cx4)<300 nF
CVT testCx < 300 nF

9

LCR range

L>20H(2kV)

R>10KΩ(2kV)

Accuracy: 1%Resolving power: 0.01

10

CVT range

Variable ratio range: 10∽10000


Accuracy: 1%

Resolving power: 0.01Accuracy: 1%

11

Exterior dimension

350(L)×270(W)×270(H)(host)

350(L)×270(W)×160(H)(accessory box)

12

Memory size

The 200 group supports U disk data storage

13

Weight(host) :22.75Kg

Weight(accessory box) :5.25Kg


IV.Panel description


picture-2-

picture-3-

1、Emergency stop

2、Reset button

3、U disk interface

4、Total power switch

5、Power input socket

6、Cn / Cx1 socket

7、Cx / Cx2 socket

8、Cx3 socket

9、Cx4 socket

10、LCD

11、Earthing terminal

12、ES self-excited output

13、Printer

14、Wiring diagram

15、HV socket

16、Earthing


4.1、Emergency stop button and high pressure indicator lamp

Installation position:Figure4—1—1

Function:A high voltage output in the instrument testing process, in case of emergency need to disconnect the high voltage output, you can press the emergency stop button immediately cut off the high voltage output from the inside; button built-in indicator light lamp as a high voltage output.

4.2、Reset button

Installation position:Figure4—1—2

Function:Instrument reset function.

4.3、U disk interface

Installation position:Figure4—1—3

Function:Test data can be stored inside the instrument into and save to U disk.

Be careful:During the data transfer process is strictly prohibited to pull out the U disk, only when the data transfer is completed and the LCD screen appears to pull out the U disk after the tip, you can pull out the U disk, otherwise it may burn U disk.

4.4、Total power switch

Installation position:Figure4—1—4

Function:Turn on the switch and power on the instrument. Turn off the switch and turn off all the power supply in the instrument. The switch should be switched off immediately and unplug the power cord.

4.5、Power input socket

Installation position:Figure4—1—5

Function:Power supply for instrument.

Wiring method:Use a standard socket to connect to a mains or generator.

Be careful:A power socket with internal fuse protection device, under normal circumstances can be burned to make insurance instrument power, protection of internal instrument.

4.6、Standard capacitor input Cn/Cx1 socket

Installation position:Figure4—1—6

Function:External standard test signal.

Wiring method:When the external standard test, the cable core wire is connected with the standard capacitance test end. The standard capacitor connection method is not the same as in the standard test, whether it is positive or reverse connection. This method is used for external high voltage standard capacitor, high voltage dielectric loss measurement.

4.7、Low input Cx/Cx2 socket

Installation position:Figure4—1—7

Function:The test signal of the test sample is input in the normal connection. In multi-channel test, this channel is the second channel test signal input port of multi-channel.

Wiring method:The center of the socket connection signal line black wire; metal shell with black line signal shielding layer; positive connection method of core wire sample voltage signal, if the sample voltage signal terminal shield (shielding ring such as low end), can be connected to the shield shield, no shield when the shielding layer is suspended.

Be careful:· In the process of starting the test, it is strictly prohibited to pull off the plug to prevent the current from the human body.

·When using the standard dielectric loss tester or standard capacitor to detect the accuracy of the normal connection, the full shielding plug should be used

to connect the dielectric loss device or the standard capacitor.

·During the test, the core of the socket should be connected with the zero resistance of the low voltage end of the sample, otherwise it may cause the fluctuation of the measured data.

· In case of strong interference, the connection should be disconnected when the cable is grounded.

4.8、Low input Cx3 socket

Installation position:Figure4—1—8

Function: In multi-channel test, this channel is the third channel test signal input port of multi-channel.

Wiring method:The center of the socket connection signal line black wire; metal shell with black line signal shielding layer; positive connection method of core wire sample voltage signal, if the sample voltage signal terminal shield (shielding ring such as low end), can be connected to the shield shield, no shield when the shielding layer is suspended.

Be careful:· In the process of starting the test, it is strictly prohibited to pull off the plug to prevent the current from the human body.

·When using the standard dielectric loss tester or standard capacitor to detect the accuracy of the normal connection, the full shielding plug should be used to connect the dielectric loss device or the standard capacitor.

·During the test, the core of the socket should be connected with the zero resistance of the low voltage end of the sample, otherwise it may cause the fluctuation of the measured data.

· In case of strong interference, the connection should be disconnected when the cable is grounded.

4.9、Low input Cx4 socket

Installation position:Figure4—1—9

Function: In multi-channel test, this channel is the fourth channel test signal input port of multi-channel.

Wiring method:The center of the socket connection signal line black wire; metal shell with black line signal shielding layer; positive connection method of core wire sample voltage signal, if the sample voltage signal terminal shield (shielding ring such as low end), can be connected to the shield shield, no shield when the shielding layer is suspended.

Be careful:· In the process of starting the test, it is strictly prohibited to pull off the plug to prevent the current from the human body.

·When using the standard dielectric loss tester or standard capacitor to detect the accuracy of the normal connection, the full shielding plug should be used

to connect the dielectric loss device or the standard capacitor.

·During the test, the core of the socket should be connected with the zero resistance of the low voltage end of the sample, otherwise it may cause the fluctuation of the measured data.

· In case of strong interference, the connection should be disconnected when

the cable is grounded.

4.10、touch panel(LCD screen should avoid prolonged exposure to sunlight, avoid heavy extrusion and sharp scratches)

Installation position:Figure4—1—10

Function:Full touch screen(120mm×90mm),Clear every step of the operation。

4.11、Earthing terminal

Installation position:Figure4—1—11

Function:Instrument protection grounding.

Be careful:The instrument is equipped with a grounding protection device, the test should ensure reliable access network. Otherwise, the instrument will automatically generate protection without starting the boost test.

4.12、ES self-excited output

Installation position:

Function:The output end of the instrument for self, self output transformer (transformer end grounded), dielectric loss test method CVT connected to self self excitation coil CVT (da), dn ground, provide the required measurement of high voltage power supply for CVT.

Be careful:Due to the low voltage output current, the instrument should be used to connect the connection line to the CVT two winding and make it in good contact, select the positive and reverse measurement, the output is off.

4.13、Printer

Installation position:

Function:When printing data can be displayed, move the cursor to the print item and press the confirm key to print.

Be careful:Printer for automatic thermal printer, print paper width 55mm. Please replace the print paper using thermal printer paper for printer, first press the lower convex button, the printer cover will automatically bounce, then according to the order of a printing paper printing paper into the cabin and leave a little part in the outside, finally close the printer cover.

4.14、Wiring diagram

Installation position:

Function:Schematic diagram describing connection mode.

Be careful:Pay special attention to the connection mode and the functions corresponding to the operation, otherwise it is easy to damage the instrument.


4.15、High voltage output HV socket

Installation position:Peripheral protection door。

Function:High frequency output of the instrument; detect the test current of the reverse wiring; the high voltage end of the internal standard capacitor.

Wiring method:The center of the socket connection red high-voltage wire; metal shell connected red high-voltage wire shielding layer; positive connection method when the core wire and the shielding layer can be made of wire sample high voltage side pressure; reverse law can only be used when the core line to test the high-voltage end pressure, if the sample pressure end shield (such as high pressure shielding ring end), can be connected to the shield shield, no shield shield layer suspended.

Be careful:· In the process of starting the test, the socket has a high voltage and an

electric shock hazard, and it is absolutely forbidden to touch the high-voltage socket and the related equipment.

· When using the standard dielectric loss tester or standard capacitor to detect the

accuracy of the normal connection, the full shielding plug should be used to connect the dielectric loss device or the standard capacitor.

· During the testing process, we should ensure that the high voltage wire core of the outlet center is connected with the zero resistance of the high voltage side of

the sample, otherwise it may cause the fluctuation of the measured Results.

4.16、Earthing

Installation position:

Function:Anti-interference grounding of high-voltage line during instrument measurement.

Be careful:Be careful not to approach the high-voltage connector, otherwise it will cause high-voltage discharge, and it will not boost voltage. Please do not turn off the grounding protection function during the test, and the grounding of the instrument must be reliable.


FAQ

1.Is it all right to make customer's own brand name?

If the quantity is huge, we accept the customzied brand name and logo.

2. Are you a manufactuer or trading company?

we are the ISO manufacturer with 20 years experience in high voltage test equipment's producing.

3. Can you do the design for us?

Sure, if you can provide your detail requirements.

4. Packaging & Shipping:

woodencases with firm foam & by Express, by sea, by Air.

5.What about the lead time for mass production?

Most we have materials at stock, lead time is within 7 days, if there is no material stock,it will take 15-20 days.

6.What are your main products?

high voltage test equipment, transforemer tester, ct pt analzyer, insulation resistance tester,hv switchgear tester, relay tester ,cable fault locator, etc.

7.What is your terms of delivery?

50% deposit, the balance should be paid before delivery or irrevocable L/C at sight

8.When can I get the price?

Regular model, we can quote you within 12 hours. customized model, we will try to reply you within 24 hours.

9.Where is your company?

Wuhan, China.

10.Where is your loading port?

Wuhan, Shanghai, Guangzhou, Ningbo or any other Chinese port as your required.

11.How soon we can get response from your team?

usually, we can reply you within 12 hours.

12.If we have some other product requirements that your page don't include, can you help to supply?

sure, you can contact us by or , we will try our best to assit.

13.What's the list of certificates you holds?

CE , ISO ,any calibration certificate as your required.

14.Are you in stock?

It depends ont the model series and model specifications.

15Does your product have warranty service?

How long is the warranty period?

Yes, we have warranty service! usually, our warranty service is 12 months, but we also can extend our warranty service as your required.


Service Process

“Customer-centered, quality-based" is our concept, we have been committed to providing the superior pre-sale, on-sale, after-sale service for our clients.

1. Dear Customer, Whatever you need, as long as you contact us, the rest can be handed over to us!

2. Our customer service staff will provide you with professional product recommendations and technical solutions.

3. The service records will be set up after we get your requirement,meanwhile, the after-sale service method also can be negotiated with you!

4. If necessary, we will arrange for professional technical engineers to provide you with video, telephone contact and on-site commissioning services as agreed with you.

5. The engineer will explain to you in detail about product’s working theory and operation.

6. The engineer will guide you to finish the whole test process by video or on-site ,and give professional answers to your technical questions.

7. The engineer will also carry out a comprehensive inspection of the products you purchase, if there is a failure, and solve the problem together.

8. After the completion of the service, please kindly give us valuable advice or suggestions on our service. The service information will be synchronized to the after-sales service center.

9. Our after-sales service center will actively follow up the progress of service, and regular follow-up visits.


Service and Support

Strictly factory test

All products will be assembled and test strictly accoriding with our product process standard. All qualified products will be issued factory release reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.

Providing technical materials

During the product acceptance, we provide the related manual sheets, packing list,qualified certificate labels, factory test reports and other technical documents.

3. Support technical guidance

We also provide the training for the operators. Complete training includes the skilled operations of our equipment, maintenance and troubleshooting . it also ranges the commissioning and test of our products at site!

Export packaging is generally divided into: transport packaging and sales packaging. There are many functions of export commodity packaging, which can be roughly summarized in the following three aspects:

(1) Protection function

The protection function is the most basic function of export commodity packaging. In order to prevent the quality and quantity of exported goods from being damaged or deteriorating during the process of transportation, storage, and sales to foreign markets, the following 8 points should be paid attention to:

1. According to the form, characteristics, transportation environment, sales environment and other factors of the export commodities, use appropriate packaging materials and design a reasonable packaging structure to protect the export commodities. For example, in the past, the inner packaging design of silk clothing was not good, the packing space was too large, the sealing was not firmly bonded, the lid of the box was often sag, and the packing tape was easy to fall off. After the export, the clothing was severely stolen due to improper packaging, leading to claims. Then the original overlapping box was changed to a flat box, sealed with plastic tape and sealing nails, and finally sealed with a special seal. This greatly increased the anti-theft ability and foreign merchants were very satisfied with the new packaging.

2. In packaging design, not only the physical and chemical forces such as punching, pulling, torsion, and compression caused by packaging machinery on packaging materials should be considered, and packaging materials that can withstand these external forces should be selected to protect the contents. In the process of commodity circulation, due to shaking, sudden braking, bumping, falling and other reasons to damage the contents, appropriate measures shall be taken to strengthen the strength of the packaging.

3. Storage and stacking will make the containers and contents under the stack bear a lot of weight. In order to prevent damage to the packaging container or inner packaging, the pressure resistance of the packaging structure must be considered.

4. One of the functions of packaging is to contain goods. Gaseous, liquid, powder and loose items cannot be transported and sold without packaging. Therefore, the packaging material should be resistant to chemical corrosion of the contents. For example, certain detergents in shampoos can cause environmental stress cracking of polyethylene bottles or delamination of composite films, and the isopropyl myristate contained in some cosmetics may soften polystyrene and so on. In addition, chemical and dust pollution from the outside must also be considered. Sometimes it pollutes not only the product itself, but also the pattern of the packaging itself. For example, in petrochemical companies and other areas, the sulfurous acid gas in the atmosphere and the packaging printing ink undergo chemical changes, which can cause color fading.

5. Friction resistance is also an aspect of protection. Due to the bumps during transportation, the product bounces or rotates in the package, which will cause surface friction and make its trademark or other signs unclear, especially when convex patterns or bronzing characters are used. This damage is more serious. Various lining structures should be used to fix or isolate products to reduce friction.

6. Attention should be paid to the climatic differences and seasonal temperature and humidity changes between export manufacturers and foreign target markets and regions along the route. If the packaging materials cannot adapt to these changes, the packaging and its contents will be dry, cracked, damaged, degraded in quality, and rusted.

7. The light will not only cause the printing surface to lose color, but also cause the loss of food quality and flavor, and medicine failure. Therefore, light-resistant inks can be used to prevent changes in the color of the pattern displayed by the packaging, and light-shielding materials such as metal, aluminum foil, colored glass, colored plastic, and opaque paper can be used to prevent deterioration of the contents due to light.

8. The protective functions of the packaging also include anti-corrosion, moisture-proof, and anti-theft. Anti-insect, anti-mildew, fragrance preservation, sterilization, protection from heat or cold, and waterproof, etc., all of which should be based on the nature, form, function of the exported goods and different factors related to the domestic and foreign marketing environment (including related foreign packaging The legal requirements), the design of different protection functions, the relevant details will be discussed in the following chapters.