HT-LA511 High-Content Oxygen Analyzer

Model
Nature of the Manufacturer
Manufacturer
Product Category
High oxygen analyzer
Place of Origin
City, Province
Overview
HT-LA511 High-Content Oxygen Analyzer
Product Details

    Measurement Principle: Ion current (limiting current)

    Display Mode: 5-digit high-light LED display

    Measurement Range: 10.00%~98.00% O2

    Measurement Accuracy: ≤±1.5%FS

    Resolution: 0.01%

    Repeatability: ≤±1.0%FS

    Response Time: T90≤30S

    Output Port: 4-20mA (Non-isolated output, load resistance<1KΩ)

    1 way of programmable alarm output (Dry contact type, maximum load 220V/2A)

    Power Supply: AC220V±10% 50/60Hz, power dissipation <30VA

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <100%RH, non-condensing

    Sample Gas Temperature: 0℃~50℃

    Sampling Mode: Gas in

    Gas Inlet Pressure: Stable pressure (control the pressure within the recommended limits to make sure the flow is within 400~600mL/min)

    Gas Outlet Pressure: Free venting (under safe conditions)

    Background Gas: N2 or other inert gas

    External Size: 80mm×160mm×142mm m (H×W×D)

    Hole-Cutting Size: 76mm×151mm m (H×W)

    Sensor Service Life: >4 years (under normal conditions of use)

    Gas Circuit Port: Φ6 plastic tube fitting

    Installation Method: Embedded mounting

    a. Friendly communication menu allows an intuitive and convenient operation;

    b. The original imported limiting current sensor consumes no service life when the power is off, and has a long service life and is easy to maintain, etc.;

    c. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

    d. Automatic temperature compensation function could reduce the impact of environmental temperature changes on the measurement accuracy;

    e. No calibration gas is needed and the instrument is not affected by the oxygen content in the operation environment;

    f. The measurement range is 10.00%~98.00%O2;

    g. Oxygen analyzer or transmitter are available for clients to choose;

    h. The analyzer has one way of 4-20mA analog output.

    It is widely used in the real-time detection and analysis of high concentration oxygen in large air separation for high purity oxygen, medical and industrial oxygenerator, smelting industry, medical and health care, petrochemical industry, environmental protection, electronic power and other industries.

    Measurement range

    Measured gas pressure

    Background gas composition