Measurement Principle: Ion current (limiting current)
Display Mode: 64×48 matrix dot OLED
Measurement Range: 10.00%~98.00% O2
Measurement Accuracy: ≤±1.0%FS
Resolution: 0.01%
Repeatability: ≤±1.0%FS
Response Time: T90≤30S
Output Port: 4-20mA.DC (Non-isolated output, load resistance<1KΩ)
2 ways of programmable alarm output (Dry contact type, maximum load 220V/2A)
Communication Port: RS485
Power Supply: DC24V±10%,500mA
Environment Temperature: -10℃~+50℃
Storage Environment Humidity: <90%RH, non-condensing
Operation Environment Humidity: <100%RH, non-condensing
Sample Gas Temperature: 0℃~50℃
Sampling Mode: Gas in
Gas Inlet Pressure: Stable pressure (control the pressure within the recommended limits to make sure the flow is within 400~600mL/min)
Gas Outlet Pressure: Free venting (under safe conditions)
Background Gas: N2 or other inert gas
Size: 110mm×99mm×45mm (H×W×D)
Hole-Cutting Size: 96mm×25mm (H×W)
Gas Circuit Port: Φ6 fast-inserting joint (sensor built in)
Sensor Service Life: >4 years (under normal conditions of use)
Installation Method: Wall mounting/guide rail mounting (optional)