On-line COD automatic analyzer
CODG-3000 on-line COD automatic analyzer can work automatically and continuously according to the on-site settings for a long time, which is widely used in industrial pollution sources, industrial process wastewater, industrial sewage treatment plant wastewater, municipal sewage treatment plant wastewater and other occasions. According to the complexity of field test conditions, the corresponding pretreatment system can be selected to ensure the reliability of the test process and the accuracy of the test results, and fully meet the field requirements of different occasions.
Chemical oxygen consumption (COD) refers to the mass concentration of oxygen corresponding to oxidant consumed when organic and inorganic reducing substances in water samples are oxidized by strong oxidant under certain conditions. COD is also an important index to reflect the pollution degree of water body by organic and inorganic reducing substances. CODG-3000 online COD automatic analyzer can work automatically and continuously according to the field settings, and is widely used in industrial pollution sources, industrial process wastewater, industrial sewage treatment plant wastewater, municipal sewage treatment plant wastewater and other occasions. According to the complexity of field test conditions, the corresponding pretreatment system can be selected to ensure the reliability of the test process and the accuracy of the test results, and fully meet the field requirements of different occasions.
Chemical oxygen consumption (COD) refers to the mass concentration of oxygen corresponding to oxidant consumed when organic and inorganic reducing substances in water samples are oxidized by strong oxidant under certain conditions. COD is also an important index to reflect the pollution degree of water body by organic and inorganic reducing substances

Features of the instrument: The unique design makes this product have lower failure rate, lower maintenance, lower reagent consumption and higher cost performance than similar products. 1-select valve assembly: select reagent sampling sequence, with flexible channels, varied functions, minimum dead volume, easy maintenance and long service life. 2-Micro-metering component: Accurate metering of reagents is realized by visual photoelectric system, which overcomes the quantitative error caused by wear of peristaltic pump tube; At the same time, the accurate quantification of trace reagents was realized, and each dose was only 1 ml, which greatly reduced the amount of reagents used. 3-Sample injection component: peristaltic pump sucks under negative pressure, and there is always an air buffer zone between reagent and pump pipe, which avoids the corrosion of pump pipe; Meanwhile, the reagent mixing is simpler and more flexible. 4-Sealed digestion component: high temperature and high pressure digestion system accelerates the reaction process and overcomes the corrosion of equipment caused by volatilization of corrosive gas in open system. 5-Reagent tube: Imported modified PTFE transparent hose with a diameter greater than 1.5mm is adopted, which reduces the probability of clogging of water samples.
Technical parameters:
Methodological basis | National Standard GB11914-89 "Water Quality-Determination of Chemical Oxygen Consumption-Potassium Dichromate" |

|
measuring range | 0-1500 mg/L |
temperature compensation | 0~60℃ |
precision | ±10% |
resolution ratio | 0.01mg/L |
repetitiveness | ±5% |
Measurement period | It can be set in 5 ~ 120 min |
Power Supply | 220V±10% 50±1 Hz |
Calibration period | Adjustable at any time at any interval from 1 to 99 days |
Maintenance cycle | Generally, once a month, each time about 30 minutes |
output | RS-232 or 4-20mA or RS485 |
Enclosure size | Height 1500× width 550× depth 450(mm) |
environmental requirement | In the room with adjustable temperature, the recommended temperature is+5 ~ 28℃; Humidity ≤90% (no condensation). For indoor use, air conditioning must be turned on. Suggested size of station building is 15m² |
other | Abnormal alarm and power failure will not lose data
|