NHNG-3010, an on-line ammonia nitrogen detector for sewage discharge, adopts Chinese LCD menu operation interface and has a unique design, which makes this product have lower failure rate, lower maintenance, lower reagent consumption and higher cost performance and accuracy than similar products. The ammonia nitrogen concentration can be measured by directly inserting the water sample riser into the system water sample without any pretreatment. The maximum measuring range of this equipment is 0~300.0mg/L NHN, and this method is mainly used for on-line automatic monitoring of ammonia nitrogen concentration of waste (sewage) water discharge point source and surface water.

The unique design makes this product have lower failure rate, lower maintenance, lower reagent consumption and higher cost performance than similar products. 1-select valve assembly: select reagent sampling sequence, with flexible channels, varied functions, minimum dead volume, easy maintenance and long service life. 2-Micro-metering component: Accurate metering of reagents is realized by visual photoelectric system, which overcomes the quantitative error caused by wear of peristaltic pump tube; At the same time, the accurate quantification of trace reagents was realized, and each dose was only 1 ml, which greatly reduced the amount of reagents used. 3-Sample injection component: peristaltic pump sucks under negative pressure, and there is always an air buffer zone between reagent and pump pipe, which avoids the corrosion of pump pipe; Meanwhile, the reagent mixing is simpler and more flexible. 4-Sealed digestion component: high temperature and high pressure digestion system accelerates the reaction process and overcomes the corrosion of equipment caused by volatilization of corrosive gas in open system. 5-Reagent tube: Imported modified PTFE transparent hose with a diameter greater than 1.5mm is adopted, which reduces the probability of clogging of water samples.
Methodological basis | Spectrophotometric determination of salicylic acid |
 |
measuring range | 0-300 mg/L |
temperature compensation | 0~60℃ |
precision | ±10% |
resolution ratio | 0.01mg/L |
repetitiveness | ±5% |
Measurement period | It can be set in 5 ~ 120 min |
Power Supply | 220V±10% 50±1 Hz |
Calibration period | Adjustable at any time at any interval from 1 to 99 days |
Maintenance cycle | Generally, once a month, each time about 30 minutes |
output | RS-232 or 4-20mA or RS485 |
Enclosure size | Height 1500× width 550× depth 450(mm) |
environmental requirement | In the room with adjustable temperature, the recommended temperature is+5 ~ 28℃; Humidity ≤90% (no condensation). For indoor use, air conditioning must be turned on. Suggested size of station building is 15m² |
other | Abnormal alarm and power failure will not lose data |